1.1. General Preventive Measures 1.2. Regulations for equipment that connects to power mains 1.3. Technical warnsigns and explanation 2. Introduction 2.1. About us 2.2. CLUSTER B2 FC 3. General Product Information 3.1. Scope of delivery 3.2. Control Functions 3.3. Features 4.
Page 3
User User Manual Manual 7. Technical Data / Diagrams 7.1 Technical drawings and measurements 7.2 IP Rating 7.3 Technical Data 7.4 DMX-Charts / Color Macro Charts / CCT Chart 7.5 RDM Templates 8. Troubleshooting 9. Manufacturer´s Declaration...
1.1.1. Please read, understand and follow the instructions. 1.1.2. Store the instructions and information in a safe place. Best solution is the ring binder provided by ROXX. 1.1.3. Follow all safety warnings. Under no circumstances remove safety warnings or other information from the equipment.
User User Manual Manual 1.1.20. Observe all disposal laws applicable in your country. Especially for the packaging. 1.1.21. Plastic bags are not a toy! Keep away from children! 1.1.22. Please note that changes or modifications which are not approved by the party responsible for compliance will void the user’s authority to operate the device.
User User Manual Manual 1.3. Technical warnsigns and explanation In order to prevent the risk of an electric shock, under no circumstances remove the cover/back or open the unit in any way! No user serviceable parts are inside. Service, maintenance and repairs should only be done by qualified service personnel or the manufacturer.
This ensures innovative, easy-to-use and performance- oriented solutions, which provide added value for our customers. Made to last Recommended for permanent outdoor use, most ROXX products feature additional corrosion protection and en- ®...
Manual 3. GENERAL PRODUCT INFORMATION 3.1. Scope of delivery 1x CLUSTER B2 FC Power cord with plug (EU country specific, if not ordered differently) Pre-installed PUK We´re offering a wide range of professional accessories (optional). Please see under menu 6 or at our website www.roxxlight.com...
4. INSTALLATION & SETUP 4.1 Physical Installation and Rigging ROXX CLUSTER B2 FC may be installed in any orientation. For this purpose the product provides several options: Standing: The fixtures Yoke includes two M8 inner threads to install the optional ROXX YOKE FLOOR EXTENSION.
Page 10
A: 3x Camlock with ¼ turn adapters B: 3x M12 / ½“ C: 1x TV Spigot 3. Using optional ROXX RIGGING BRACKET For seemless connection of multiple Blinders, to avoid gaps due to bracing of the truss structure by variable, sliding mounting positions.
Page 11
User User Manual Manual 2. Pre-Link Magnets on top and side help to allign the fix- tures due cluster process and giving support operation for convenient and save interlocking. Important Note: Even though the pre-link magnet system is strong enough to hold the devices to- gether, at least one hand must always remain on the device for support during the connection.
Page 12
User User Manual Manual The maximum loads listed here below take into account the 10-fold safety! 1. Rigging by integrated 1/4 turn Camlocks on top- or rear side Max. Tension Load: 90kg Max. Tension Load: 90kg Max. Torsion Load: 18.703 Nmm Max.
Page 13
Max. Tension Load: 88kg Max. Tension Load: 66kg Max. Torsion Load: 8.238Nmm Max. Torsion Load: 6.476Nmm 3. Using optional ROXX RIGGING BRACKET with 2x Mounting Clamps Max. Tension Load: 72kg Max. Torsion Load: 6.326 Nmm Important Note: Please be aware of using the centering PUK for safe RIGGING BRACKET installation to the...
POWER IN and POWER OUT sockets are protected from spraying water, as in accordance with IP65. 4.2.1. AC Power The CLUSTER B2 FC operates on any 100–260 V, 50/60 Hz AC mains power supply with a maximum power con- sumption of 220W.
Manual 4.2.2. DMX Connection The CLUSTER B2 FC is fully controllable by DMX (USITT DMX512-A standard, based on RS-485) and RDM. 4.2.2.1. Cable Connection If using a cabled DMX system, connect the DMX IN cable to the input connector (male 5-pin XLR connector) and DMX OUT cable to the output (female 5-pin XLR connectors).
Once the fixture is connected to AC power, the boot process starts and the following information will appear on the display: “Ready to ROXX”, the product name and the current software version. After this process, the fixture is ready for operation, and starts in the previous- ly enabled mode.
Page 17
User User Manual Manual Display Off Pressing ESC + arrow down simultaneously the display backlight function will set to off and the display will turn off immediately. Once a control is pressed the display backlight will turn on. Manual display flip function* The fixture includes an auto display flip function by default.
User User Manual Manual 5.4 Configuration Home Screen After boot process the fixture is ready for operation and starts in the previously enabled mode. At home screen the following information will appear, depending on the current operating mode: DMX Adress Operating Mode (DMX Mode, Quick Light or Standalone Mode) Next available DMX address depending on the fixtures DMX footprint External Data protocol (DMX).
User User Manual Manual Level 1 Level 2 Menu DMX Mode DMX Mode 1CH DWE 2CH DWE Stand Alone 4CH DWE Slave 9CH DWE+ Settings 6CH STROBE System Info 6CH RGB 10CH BASIC RGB 14CH BASIC RGB 13CH STANDARD RGB (default) 22CH STANDARD RGB 24CH EXTENDED RGB 33CH EXTENDED RGB...
Page 20
User User Manual Manual Auto* Select “Auto” by using the up/down arrows and press ENTER. Here at sub-menu (level 3), you can choose between 10 different Auto Effects (Effect 1 - 10) and Stop Program. Using the Up/Down arrows you can select one of the 10 Effects and confirm by pressing ENTER or step back by ESC. After confirming your preferred Effect, you can now adjust speed and brightness at level 4.
Page 21
User User Manual Manual Color Macro* 46 different color macros (34x matched LEE color filters, 6 LED colors and 6 different Whites) are available as presets. For each the brightness can be adjusted separately. Level 1 Level 2 Level 3 Menu Stand Alone Mode Color Macro...
Page 22
User User Manual Manual Quick Color* The standalone mode “Quick Color” allows a direct adjustment of the single LED colors R, G, B, A, W, Dimmer and Shutter. Level 1 Level 2 Level 3 Menu Stand Alone Mode Quick Color DMX Mode Stop Stand Alone Dimmer...
Page 23
User User Manual Manual * Note: Tint values = no function/neutral 001 - 127 = + green -001 to - 127 = - green * Note: Using UP/DOWN arrows at homescreen the selected CCT value can be changed in +/- 100K steps. Shutter: Please see detailed explanation for strobe effects inside DMX chart at the end of this manual.
User User Manual Manual Color Settings* Here at “Color Settings” you can chose your preferred working color mode for all Stand Alone modes. Either Color Calibration or RAW. Chose Color Calibration if the fixture should work accroding to the settings at Color Calibration, either Full Calibration or CCT Calibration, RAW works according to the settings at RAW Balance, either RAW or User Calibrated.
Page 25
User User Manual Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Description On= Flip control panel display by Display Flip <on/off> 180° (e.g. for overhead installation) Off= normal control panel display On= controls permanent on, display itself will deactivate after 60 minues of incativity Backlight <on/off>...
Page 26
User User Manual Manual Red 2 <0-255> Green 2 <0-255> RAW Balance (affects RAW Mode individual color calibration User Calibration Blue 2 <0-255> in DMX and Stand for R,G,B,A,W Alone Modes Amber 2 <0-255> White 2 <0-255> 800 Hz 1200 Hz 2000 Hz LED Frequency Select preferred LED PWM frequency...
Page 27
User User Manual Manual Main Menu Menu level 2 Menu level 3 Menu level 4 Menu Level 5 Description 1CH DWE, 2CH DWE, 4CH DWE, 9CH DWE+, 6CH STROBE, 6CH RGB, 10CH BASIC RGB, 14CH BASIC RGB, 13CH STANDARD RGB, 22CH STANDARD RGB, 24CH EXTENDED RGB, 33CH EX- TENDED RGB, 10CH DIRECT,...
User User Manual Manual Dimmer Curves LINEAR EXPONENTIAL LOGARITHMIC S-CURVE 5.4.6 System Info Level 1 Menu DMX Mode Stand Alone Slave Settings System Info Main Menu Menu level 2 Menu level 3 Menu level 4 Firmware Version vx.xx Display installed firmware version Serial Number 202xxxxxxxx RDM UID...
User User Manual Manual 6. ACCESSORIES Yoke 2.2 Yoke 4.3 Floor Extension Rigging Bracket Art.: 13907001 Art.: 13907101 Art.: 13907411 Art.: 13907201 Omega Bracket ST Case 4 pcs. / 8 pcs. Art.: 13907411 Art.: 90900002 Case 2 pcs / 4 pcs Art.: 13907511...
Page 30
User User Manual Manual 7. TECHNICAL DATA / DIAGRAMS 7.1 Technical drawings and measurements...
Page 31
7.2 IP Rating ROXX products conform to officially classified IP standard levels. CLUSTER B2 FC is rated to IP65 when using the co- vers for the housing parts. IP stands for Ingress Protection and IP65, according to classified standard, means shielded against dust and high-pressure jets of water from any side.
Page 32
User User Manual Manual 7.3 Technical Data Photometrics LED expected lifetime 50.000 hours Lightsource 2x 300W Red, Green, Royal Blue, Amber, Warm-White Type of optical system Reflector with Compound Eye Lens LED PWM Frequency selectable 800Hz, 1.200Hz, 2.000Hz, 3.600Hz, 12kHz, 25kHz Beam angles (50%) 50°...
Page 33
User User Manual Manual 7.3 Technical Data Operator & Controller Master Dimmer, Master Dimmer Fine, Shutter, Duration, Dimmer 1-2, Dimmer 1-2 Fine, Red 1-2, Red 1-2 Fine, Green 1-2, Blue 1-2, Blue Fine 1-2, Amber 1-2, Warm- DMX Functions White 1-2, CTC 1-2, Tint 1-2, Color Macro 1-2, Color Macro Crossfade 1-2, Dimmer Curve, Dimmer Response, Redshift, Effect, Device Settings 1CH DWE, 2CH DWE, 4CH DWE, 9CH DWE+, 6CH STROBE, 6CH RGB, 10CH BASIC RGB, 14CH BASIC RGB, 13CH STANDARD RGB (default), 22CH STANDARD...
Page 34
User Manual 7.4 DMX-Charts / Color Macro Charts / CCT Chart 1CH DWE 24CH EXTENDED RGB 2CH DWE 33CH EXTENDED RGB 4CH DWE 10CH DIRECT 9CH DWE+ 12CH DIRECT 6CH STROBE 17CH DIRECT 6CH RGB 24CH DIRECT 10CH BASIC RGB 41CH DIRECT 14CH BASIC RGB 13CH STANDARD RGB (default)
Page 35
User Manual 6CH RGB 10CH BASIC RGB 14CH BASIC RGB 13CH STANDARD RGB (Calibrated) (Calibrated / default) (Calibrated) (Calibrated) Red 1 Master Dimmer Master Dimmer Master Dimmer Green 1 Shutter Master Dimmer Fine Shutter Blue 1 Shutter Dimmer 1 Red 2 Green Red 1 Green 2...
Page 36
User Manual 22CH STANDARD RGB 24CH EXTENDED RGB 33CH EXTENDED RGB (Calibrated) (Calibrated) (Calibrated) Master Dimmer Master Dimmer Master Dimmer Master Dimmer Fine Shutter Master Dimmer Fine Shutter Duration Shutter Dimmer 1 Dimmer 1 Duration Dimmer 1 Fine Red 1 Dimmer 1 Red 1 Green 1...
Page 37
User Manual 10CH DIRECT 12CH DIRECT 17CH DIRECT 28CH DIRECT 41CH DIRECT (RAW) (RAW) (RAW) (RAW) (RAW) Red 1 Master Dimmer Master Dimmer Master Dimmer Master Dimmer Green 1 Shutter Shutter Shutter Master Dimmer Fine Blue 1 Dimmer 1 Duration Shutter Amber 1 Green...
Page 38
User Manual 1CH DWE according to selected Tunable White settings at Stand Alone Mode, default 2900K) (Calibrated / Function Value Setting Remark Default Dimmer 000-255 0 - 100% 2CH DWE according to selected Tunable White settings at Stand Alone Mode, default 2900K) (Calibrated / Function Value...
Page 39
User DMX CHART Manual 150 - 164 Strobe 6: random closing pulse (fast slow) 165 - 169 Shutter open 170 - 184 Strobe 7: burst pulse (fast slow) 185 - 189 Shutter open 190 - 204 Strobe 8: random burst pulse (fast slow) Shutter 205 - 209...
Page 40
User DMX CHART Manual 6CH STROBE MODE (Calibrated) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast slow)
Page 41
User DMX CHART Manual 6CH RGB (Calibrated) Function Value Setting Remark Default Red 1 000-255 0 - 100% Green 1 000-255 0 - 100% Blue 1 000-255 0 - 100% Red 2 000-255 0 - 100% Green 2 000-255 0 - 100% Blue 2 000-255 0 - 100%...
Page 42
Magenta -> Neutral (affects CTC and 128-128 Neutral RGB) 129-255 Neutral -> Green Color Macro Please see ROXX color macro chart (override RGB/CTC) 000 - 005 No function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade (Transition 106-214...
Page 43
User Manual 135-139 No function 140-144 LED Frequency 800Hz (hold 3s) 145-149 LED Frequency 1200Hz (hold 3s) 150-154 LED Frequency 2000Hz (hold 3s) 155-159 LED Frequency 3600Hz (hold 3s) 160-164 LED Frequency 12kHz (hold 3s) 165-169 LED Frequency 25kHz (hold 3s) 170-174 No function 175-179...
Page 44
User Manual 14CH BASIC RGB (Calibrated) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% Master Dimmer Fine 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open...
Page 45
User Manual Color Macro Please see ROXX color macro chart (override RGB/CTC) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade (Transition 106-214 11s - 119s (1s steps) Time between Color Macros) 215-244 2m - 4m50s (10s steps)
Page 46
User Manual 195-199 No function 200-204 Invert Mapping Off (hold 3s) 205-209 Invert Mapping On (hold 3s) 210-214 No function 215-219 LED Mode - Illumination (hold 1,5s) Device Settings (please see 220-224 LED Mode - Boost (hold 1,5s) remark *1) 225-229 No function 230-234...
Page 47
User Manual Red 2 000-255 0 - 100% Green 2 000-255 0 - 100% Blue 2 000-255 0 - 100% 000 - 004 5600K 2000K-6500K linear in 20-21K steps 005-182 (please see detailed CTC chart) 182-225 5600K according to CTC chart (affects RGB 1+2) 226-226 6500K...
Page 48
User Manual 145-149 LED Frequency 1200Hz (hold 3s) 150-154 LED Frequency 2000Hz (hold 3s) 155-159 LED Frequency 3600Hz (hold 3s) 160-164 LED Frequency 12kHz (hold 3s) 165-169 LED Frequency 25kHz (hold 3s) 170-174 No function 175-179 Fan Auto (hold 3s) 180-184 Fan Silent (hold 3s) 185-189...
Page 49
User Manual 170 - 184 Strobe 7: burst pulse (fast slow) 185 - 189 Shutter open 190 - 204 Strobe 8: random burst pulse (fast slow) 205 - 209 Shutter open Shutter 210 - 224 Strobe 9: sine wave (fast slow) 225 - 229 Shutter open...
Page 50
User Manual 060-064 No function 065-069 Linear Dimmer Curve (hold 1,5s) Exponential Dimmer Curve 070-074 (hold 1,5s) 075-079 Logarithmic Dimmer Curve (hold 1,5s) 080-084 S-Curve Dimmer Curve (hold 1,5s) 085-089 No function 090-094 LED (Fast) Dimmer Response (hold 1,5s) 095-099 Medium Dimmer Response (hold 1,5s) Halogen (Slow) Dimmer 100-104...
Page 51
User Manual 24CH EXTENDED RGB (Calibrated) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open Shutter 070 - 084 Strobe 2: opening pulse (fast slow)
Page 52
User Manual Color Macro 1 (override RGB 1/ Please see ROXX color macro chart CTC 1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 1 (Transition 106-214 11s - 119s (1s steps) Time between Color...
Page 53
User Manual No Function - Current Preset from Menu 000-51 Settings 052-101 Linear Dimmer Curve Dimmer Curve 102-152 Exponential Dimmer Curve 153-203 Logarithmic Dimmer Curve 204-255 S-Curve Dimmer Curve No Function - Current Preset from Menu 000-063 Settings 064-127 LED / fast Dimmer Response 128-191 Medium...
Page 54
User Manual 205-209 Invert Mapping On (hold 3s) 210-214 No function 215-219 LED Mode - Illumination (hold 1,5s) Device Settings 220-224 LED Mode - Boost (hold 1,5s) (please see 225-229 No function remark *1) 230-234 Factory Reset (hold 3s) 235-239 User Reset (hold 3s) no self-test by DMX 240-255...
Page 55
(affects CTC 1 and 128-128 Neutral RGB 1) 129-255 Neutral -> Green Color Macro 1 (override RGB 1/ Please see ROXX color macro chart CTC 1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 1 (Transition...
Page 56
User Manual 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 2 (Transition 106-214 11s - 119s (1s steps) Time between Color Macros 2) 215-244 2m - 4m50s (10s steps) 245-255 5m - 15m (1m steps) 000-15 No Function 016-039...
Page 57
User Manual 000-029 No function 030-034 Display Backlight On (hold 3s) 035-039 Display Backlight Off (hold 3s) 040-044 No function 045-049 DMX Fail Blackout (hold 3s) 050-054 DMX Fail Hold (hold 3s) 055-059 DMX Fail - Emergency Light (hold 3s) 060-124 No function 125-129...
Page 58
User Manual Blue 2 000-255 0 - 100% Amber 2 000-255 0 - 100% White 2 000-255 0 - 100% 12CH DIRECT (RAW) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast...
Page 59
Magenta -> Neutral (affects CTC and 128-128 Neutral RGBAW) 129-255 Neutral -> Green Color Macro (override RGBAW/ Please see ROXX color macro chart CTC) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade (Transition 106-214...
Page 60
User Manual 165-169 LED Frequency 25kHz (hold 3s) 170-174 No function 175-179 Fan Auto (hold 3s) 180-184 Fan Silent (hold 3s) 185-189 Fan Off (hold 3s) 190-194 Fan High Power (hold 3s) 195-199 No function Device Settings 200-204 Invert Mapping Off (hold 3s) (please see 205-209 Invert Mapping On (hold 3s)
Page 61
User Manual 190 - 204 Strobe 8: random burst pulse (fast slow) 205 - 209 Shutter open 210 - 224 Strobe 9:sine wave (fast slow) Shutter 225 - 229 Shutter open 230 - 244 Strobe 10: burst (fast slow) 245 - 255 Shutter open Dimmer 1 000-255...
Page 62
User Manual 080-084 S-Curve Dimmer Curve (hold 1,5s) 085-089 No function 090-094 LED (Fast) Dimmer Response (hold 1,5s) Medium Dimmer Response 095-099 (hold 1,5s) Halogen (Slow) Dimmer Response 100-104 (hold 1,5s) 105-109 No function Redshift On (hold 1,5s / affects only bet- 110-114 ween 2700-3500K) 115-119...
Page 63
User Manual 28CH DIRECT (RAW) Function Value Setting Remark Default Master Dimmer 000-255 0 - 100% 000 - 019 Shutter close 020 - 024 Shutter open 025 - 064 Strobe 1 (fast slow) 065 - 069 Shutter open 070 - 084 Strobe 2: opening pulse (fast slow) 085 - 089...
Page 64
(affects CTC 1 and 128-128 Neutral RGBAW 1) 129-255 Neutral -> Green Color Macro 1 (override RGBAW 1/ Please see ROXX color macro chart CTC 1) 000 - 005 no function 006-105 0,1s - 10s (0,1s steps) Color Macro Cross- fade 1 (Transition...
Page 65
User Manual 000-15 No Function 016-039 Effect 1 (slow to fast) 040-063 Effect 2 (slow to fast) 064-87 Effect 3 (slow to fast) 88-111 Effect 4 (slow to fast) Effect override RGBAW 1+2 / CTC 112-135 Effect 5 (slow to fast) 1+2, Color Macro 136-159 Effect 6 (slow to fast)
Page 66
User Manual 133-139 No function 140-144 LED Frequency 800Hz (hold 3s) 145-149 LED Frequency 1200Hz (hold 3s) 150-154 LED Frequency 2000Hz (hold 3s) 155-159 LED Frequency 3600Hz (hold 3s) 160-164 LED Frequency 12kHz (hold 3s) 165-169 LED Frequency 25kHz (hold 3s) 170-174 No function 175-179...
Page 67
(affects CTC 1 and 128-128 Neutral RGBAW 1) 129-255 Neutral -> Green Color Macro 1 (override RGBAW 1/ Please see ROXX color macro chart CTC 1) 000 - 005 no function Color Macro Cross- 006-105 0,1s - 10s (0,1s steps) fade 1 (Transition...
Page 68
128-128 Neutral RGBAW 2) 129-255 Neutral -> Green Color Macro 2 (override RGBAW 2 Please see ROXX color macro chart / CTC 2) 000 - 005 no function Color Macro Cross- fade 2 (Transition 006-105 0,1s - 10s (0,1s steps)
Page 69
User Manual 136-159 Effect 6 (slow to fast) 160-183 Effect 7 (slow to fast) Effect override RGBAW 1-4 / CTC 184-207 Effect 8 (slow to fast) 1-4, Color Macro 1-4 208-231 Effect 9 (slow to fast) 232-255 Effect 10 (slow to fast) No Function - Current Preset from Menu 000-51 Settings...
Page 70
User Manual 165-169 LED Frequency 25kHz (hold 3s) 170-174 No function 175-179 Fan Auto (hold 3s) 180-184 Fan Silent (hold 3s) 185-189 Fan Off (hold 3s) 190-194 Fan High Power (hold 3s) 195-199 No function Device Settings 200-204 Invert Mapping Off (hold 3s) (please see 205-209 Invert Mapping On (hold 3s)
Page 71
User User DMX CHART DMX CHART Manual Manual Color Macro Chart for DMX Gels - Color Macros for DMX Gels - Color Macros for DMX DMX value Gel Name Color Number 093-095 Magenta LEE 113 000-005 no function 096-098 Mauve LEE 126 006-008 100% Red LED...
Page 72
User User Manual Manual Color Macro Chart for Stand Alone Gels - Color Macros for Standalone Mode Gels - Color Macros for Standalone Mode Position Gel Name Color Number Position Gel Name Color Number 100% Red LED Lavender LEE 058 Fire LEE 019 Magenta...
Page 73
User User Manual Manual CTC channel DMX / Color temperature 10.000 9.500 9.000 8.500 8.000 7.500 7.000 6.500 6.000 5.500 5.000 4.500 4.000 3.500 3.000 2.500 DMX (step) 2.000...
Page 74
User User Manual Manual CTC-Chart Color Color Color Color Color Color Temp Temp Temp Temp Temp Temp (Step) (Step) (Step) (Step) (Step) (Step) (°K) (°K) (°K) (°K) (°K) (°K) 5600 4525 2774 3649 5400 6276 5600 4545 2794 3670 5421 6296 5600 2814...
Page 75
* Note: During RDM identifying process CLUSTER B2 FC flashes white to blue color alternately. RDM functions For easy identifying ROXX CLUSTER B2 FC during RDM process the unit will jump from white color to blue color every second. Function...
Page 76
User User Manual Manual 0x8026 User Calibration- Green 2 0x8027 User Calibration- Blue 2 0x8028 User Calibration- Amber 2 0x8029 User Calibration- White 2 1= 800Hz / 2= 1200Hz / 3= 2000Hz / 4= 3600Hz / 5= 12kHz / 6= 0x8059 LED Frequency (PWM) 25kHz...
Page 77
User Manual Sensors RDM enables various readouts for remote device monitoring. See the table below for sensors and sensor types. Please note: The RDM controller communicates with the fixtures to show only the available sensors for this fixture. The table is subject to change without notice. Name Temperature xx°C / xxx°F...
Page 78
Hansestr. 91 51149 Köln Email: info@roxxlight.com or the ROXX authorized reseller in your country, from where you purchased your product. Correct Disposal of this product This is for the European Union and European countries with electrical waste collection systems. When this label is shown on the product or brochure it means that the item cannot be disposed with household waste.
Page 79
User User Manual Manual CE Compliance The equipment marketed by ROXX GmbH complies (where applicable) with the essential requirements and other specifications of the following Directives: • 2014/30/EU (EMC) • 2014/35/EU (LVD) • 2011/65/EU (RoHS) The complete EU- and UK-Declaration of Conformity can be found at www.roxxlight.com/support, or you can also request it at info@roxxlight.com...
Need help?
Do you have a question about the CLUSTER B2 FC and is the answer not in the manual?
Questions and answers