13
90°
1.
A
12
14
Once the desired quantity has been dispensed, move the Opera-
ting Handle (Ref. 11) back to the Lock Release Knob (Ref. 12), when
you will hear it engage and it will not rotate any further.
CAUTION
!
because kickback is likely.
At this point, the outside of the easyconnect cap must be rinsed.
Before rinsing, lower and release hose so liquid can flow away from
13
coupler.
CAUTION
!
A
residue from the internal parts of Cleanload Nexus, so it must always
be carried out correctly to eliminate the risk of contamination.
To activate rinse, rotate the Rinse Water Lever (Ref. 13) 90 degrees
clockwise (1) and raise it. (2) to release rinse water.
B
NOTE: when the Rinse Water Lever is in the raised 'ON' (position
2A), the Operating Handle cannot be moved.
2.
A
ON
11
NOTE: If the Operating Handle (Ref. 11) is NOT in the correct rinse
position (A), the Rinse Water Lever (Ref. 13) will rotate partially but
not engage or operate rinse.
CAUTION
!
smoothly. If it does not, then check the Operating Handle is aligned
with the Lock Release Knob. Never attempt to force the Rinse
Water Lever.
CLEANLOAD NEXUS
Hold the Suction Hose tightly at arms length
This rinse procedure also removes chemical
B
OFF
The Rinse Water Lever should turn and engage