5.4 Connecting the Rinse Water Supply Hose

∙ Cleanload Nexus must be connected to a clean water source.
∙ Where possible use at least 5 bar rinse water pressure for op-
timum container cleaning.
6

6. OPERATION

6.1 Preparation for use

∙ Set-up the tractor/sprayer in the same way as when filling via
the induction bowl (refer to instructions from your sprayer
manufacturer).
∙ The Cleanload Nexus Operating handle must always be closed
(handle fully to the left) when a product container is not
attached. This ensures that all valves inside the Cleanload
Nexus are closed and no air or liquid movement can occur.
10
1
2
5
4
3
CLEANLOAD NEXUS
∙ Always ensure that the Rinse Water Supply Hose is secured
and does not present a hazard when using or transporting the
Cleanload Nexus.
The Rinse Water Supply Hose (Ref. 7) connects to the Rinse
Water Supply Hosetail (Ref. 9) at position A.
Cleanload Nexus is supplied with the Internal Rinse Water Hose
(Ref. 10) and a check valve already connected at position B.
Place one of the Ear Clamps (Ref. 8) over the Rinse Water Supply
Hose (Ref. 7) and push the hose securely onto the Rinse Water
Supply Hosetail (Ref. 9). Use a crimping tool to securely connect
the hose.
Ensure the hose is securely fitted before turning
WARNING
!
on the water supply.
A Hosetail with 3/8" thread and a 22-15 mm ear clamp are provided
to connect the other end of the Rinse Water Supply Hose (Ref. 7)
to a suitable external supply.
The water can be drawn from either the same supply as the
induction bowl or from an alternative clean water supply.
The diagram shows an example of a temporary rinse water
supply connection using male and female dry break connectors.
(not included).
1
To clean water source
2
Hosetail connector
3
Hose clamp
∙ Ensure that all sprayer suction available is allocated to the
Cleanload Nexus suction line. For example by shutting off the
suction to the induction bowl with a suitable valve.
∙ Start the sprayer filling pump to create suction.
∙ Check that clean water is connected to Cleanload Nexus, but
DO NOT operate the Rinse Water Lever at this stage.
The suction must always be turned on and
WARNING
!
drawing from the Cleanload Nexus before a container is
attached.
PNR-CN100-OIPM (10/12/21) ©2021 Pentair. All Rights.
4
Male dry break connector
5
Female break connector
6
Rinse water hose