Instructions for use
1.
The instructions for use and warning are guides to the proper use of the
respirator and to prevent health risk. They must be carefully read, completely
understood and properly followed. If using the respirator in work environment: the
wearer of the respirator must be well trained to use it properly before starting
work.
2.
Before the occupational use of this respirator, a written respiratory protection
program must be implemented meeting all the local government requirements. In
the United States employers must comply with OSHA 29 CFR 1910.134 which
includes medical evaluation, training, and fit testing.
3.
No alteration or modification is allowed to the respirator. The respirator
should not be worn when it is contaminated (eg. dusty, wet, etc) or damaged (eg.
Broken part, hole, etc). The contaminated or damaged respirator must not be
used and must be replaced with a new one.
4.
The respirator must not be used continuously for more than a single work
shift. Always replace with a new respirator, whenever the breathing resistance
becomes excessive or after using continuously for a single work shift.
5.
The valve cap is reusable. To clean and disinfect, please wipe its surface with
a damp and soft cloth or wet tissue or alcohol wipe. Do not use strong chemical or
abrasive solvent to clean the valve cap.
6.
While in use, avoid touching the respirator. It is important to consider the
respirator as potentially contaminated upon removal and user should wash hands
thoroughly with soap and water or using an alcohol-based hand-rub.
AIR+ SMART MASK
With Micro Ventilator
1

Advertisement

loading

Summary of Contents for NIOSH AP522VL

  • Page 1 AIR+ SMART MASK With Micro Ventilator Instructions for use The instructions for use and warning are guides to the proper use of the respirator and to prevent health risk. They must be carefully read, completely understood and properly followed. If using the respirator in work environment: the wearer of the respirator must be well trained to use it properly before starting work.
  • Page 2 To remove the respirator, handle only the elastic bands starting with the bottom and then the top. Lift the respirator away from the face and discard properly in a designated waste receptacle. The “Lot” code represents the production date in yyyy/mm/dd format. The “Exp”...
  • Page 3 User Instructions for Micro Ventilator 1. For use of the respirator with the micro ventilator, please attach and switch on the micro ventilator before wearing the respirator. 2. The operating time of the Micro Ventilator is estimated at 2.5 hours. The respirator can still be used independently even when the micro ventilator stops working or if the micro ventilator is not attached.
  • Page 4 3. The Micro Ventilator needs to be fully charged prior to initial use. It can be recharged using the attached USB cable by connecting to a powered USB port or power bank. Please note, for safety reasons, it is not advised to use any other USB cable aside from the one provided with the device.
  • Page 5 User Instructions for Respirator...
  • Page 6 1. Before using, check the respirator for holes, tears or other damage to its surface, strap and/or nose cushioning to ensure that your respirator works well. Replace with a new respirator, if damaged or damp. Select the right respirator size to fit your face. Consult the given size chart on the box for size selection.
  • Page 7: Safety And Precaution

    If this respirator is intended to be used with the micro ventilator, OSHA fit testing should be performed with the ventilator turned on. Model AP522VL filtering facepiece has been manufactured by Champak Enterprise Co., Ltd. for Innosparks Pte Ltd under TC-84A-7842.
  • Page 8: Legal Disclaimer

    Legal Disclaimer 1. Reproduction, transfer, distribution or disassembly of this product in any form is prohibited. 2. This product is being sold “as-is”. Unless expressly provided, our company does not provide any warranty of the product, whether implied or statutory, including, but not limited to, any warranty of merchantability or fitness for a particular purpose.
  • Page 9 O - Refer to User's Instructions, and/or maintenance manuals for information on use and maintenance of these respirators. P - NIOSH does not evaluate respirators for use as surgical respirators. Special or critical User Instructions and/ or specific use limitations apply.
  • Page 10 Warning Do not use the respirator as protection against toxic particle, gas, vapor or solvent from spray-painting operation. Those who have difficulty breathing must take caution when using the respirator to ensure that their ability to breathe is not further hindered by wearing the respirator. Do not use the respirator in enclosed space, tank, inadequately ventilated area, oxygen-deficient environment (<19.5% in volume), hazardous environment, or in any circumstance where toxic gas is likely to be present.
  • Page 11 Innosparks Pte Ltd 75 Ayer Rajah Crescent #02-13 Singapore 139953 Model number: AP522VL Made in Taiwan...