Balluff BIS C-60 2 Series Manual

Balluff BIS C-60 2 Series Manual

Electronic identification systems profibus dp with memory optimization

Advertisement

Quick Links

All manuals and user guides at all-guides.com
C60_2-028_823024_0401-e.p65
1
2
No. 823 024 D/E • Edition 0401
Subject to modification.
Replaces edition 0301.
http://www.balluff.de
http://www.balluff.de
http://www.balluff.de
http://www.balluff.de
http://www.balluff.de
Balluff GmbH
Schurwaldstrasse 9
73765 Neuhausen a.d.F.
Germany
Phone +49 (0) 71 58/1 73-0
Fax +49 (0) 71 58/50 10
E-Mail: balluff@balluff.de
2
E
Electronic Identification Systems BIS
Processor BIS C-60_2
Profibus DP with Memory Optimization
Deutsch – bitte wenden!
Manual

Advertisement

Table of Contents
loading

Summary of Contents for Balluff BIS C-60 2 Series

  • Page 1 No. 823 024 D/E • Edition 0401 Subject to modification. Replaces edition 0301. http://www.balluff.de http://www.balluff.de http://www.balluff.de http://www.balluff.de http://www.balluff.de Balluff GmbH Schurwaldstrasse 9 73765 Neuhausen a.d.F. Germany Phone +49 (0) 71 58/1 73-0 Fax +49 (0) 71 58/50 10 E-Mail: balluff@balluff.de...
  • Page 2: Table Of Contents

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Contents Safety Considerations ......................... 4 Introduction BIS C Identification Systems ................5-7 BIS C-60_2 Processor, Basic knowledge for application ............8 Optimized data carrier memory management ........9-11 BUS interface PROFIBUS-DP ....................12-14 Compatibility with BIS C-6_2 processor ..................
  • Page 3: Introduction Bis C Identification Systems

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Introduction BIS C Identification Systems This manual is designed to assist the user in setting up the control program and installing and starting up the components of the BIS C Identification System, and to assure rapid, trouble- free operation.
  • Page 4: Bis C-60_2 Processor Basic Knowledge For Application

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Introduction BIS C Identification Systems Configuration with PROFIBUS-DP BIS C-6022 processor Processor BIS C-6022 Processor BIS C-6022 Read/write heads Schematic Data carriers BIS C-1_ _-... representation of an identification system (example) ) BIS C-3_ _ series, except BIS C-350 and -352 BIS C-60_2 Processor Basic knowledge for application Selecting System...
  • Page 5: Optimized Data Carrier Memory Management

    Optimized data carrier memory management Protocol The BIS C-60_2-028 version works with a further developed Balluff protocol, which optimizes memory handling in the data carrier. This version would be required whenever the required number of write cycles exceeds the number permitted for the EEPROM in the data carrier.
  • Page 6: Bus Interface Profibus-Dp

    In this method the PLC cycle is unaffected nor is the bus access time changed. All that is required is that a byte in the data buffer be used for the 2nd bit header instead of for user data. This 2nd alternative is the Balluff recommended setting (factory default).
  • Page 7 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BUS interface PROFIBUS-DP Unit's Master Data For the correct parametering of the bus master as per type, a diskette, containing the unit’s master data in the form of a GSD file is included with the BIS C-60_2 processor. Station Address The Processor BIS C-60_2 is delivered with the station address 126.
  • Page 8: Compatibility With Bis C-6_2 Processor

    LED display in the user’s manual for the BIS C-6_2 proces- sor! This user’s manual can be mailed on request, or you may download it from the Internet at www.balluff.de. In “Compatible with BIS C-6_2” mode, the error code also has the error number 19 added.
  • Page 9: Input And Output Buffers

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Input and Output Buffers Input and Output In order to transmit commands and data between the BIS C-60_2 and the host system, the Buffers latter must prepare two fields. These two fields are: –...
  • Page 10: Output Buffer, Configuration And Explanation

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Output buffer, configuration and explanation Configuration of the The last byte can be arranged as a 2nd bit header through parametering (default). output buffer for one (1) read/write head Description of Sub- Meaning Function Description...
  • Page 11 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Output buffer, configuration and explanation Description of Sub- Meaning Function Description Output Buffer address (continued) Start address Address at which reading from or writing to the data carrier begins (Low Byte) (the Low Byte includes the address range from 0 to 255).
  • Page 12: Input Buffer, Configuration And Explanation

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Input buffer, configuration and explanation Configuration of the The last byte can be arranged as a 2nd bit header through parametering (default). input buffer for one (1) Read/Write head Description of Sub- Meaning Function Description...
  • Page 13 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Input buffer, configuration and explanation Description of Sub- Meaning Function Description Input Buffer address (continued) Error code (continued) Data carrier was removed from the active zone of the read/write head while it was being written. 07Hex AV bit is set but the command designator is missing or invalid.
  • Page 14: Parametering The Bis C-60_2 Processor

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Parametering the BIS C-60_2 processor Parameters, There are 6 user parameter bytes stored on the Profibus master that can be used to activate Overview and deactivate various functions. Setting is done directly by linking a device to the Profibus master.
  • Page 15: Processing Data Carriers

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Parametering the BIS C-60_2 processor Parametering Bytes 4th byte, bit 8, Arrange a 2nd bit header at the end of the input and output buffers. (continued) If this function is selected, then the minimum size of both buffers is 4 words (8 bytes) each. 4th byte, bit 7, Display state of the digital input in the bit header of the input buffers: 0 = no...
  • Page 16: Reading And Writing In Dynamic Mode

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Processing data carriers Special To adjust the read/write functions to the numerous possible applications, a few unique fea- characteristics tures have been implemented that the user can select and set when parametering or program- ming the processor.
  • Page 17: Monitoring Data Carrier Initialization

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Processing data carriers Mixed Data Access The following shows the structure of a program: (cont.) Program structure Subaddress Value Range Command designator 1. Program record Program number to 0A 1st data record: Start address Low Byte Start address High Byte Number of bytes Low Byte...
  • Page 18: Examples For Protocol Sequence

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Examples for protocol sequence Example No. 1 Initializing the data carrier for memory optimization (data carrier type with 32 byte block size) For configuring with Host: BIS C-60_2 Identification System: double bit header and 8-byte buffer 1.) Process subaddresses of the output buffer in the...
  • Page 19 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Examples for protocol sequence Example No. 4 Read 17 bytes starting at data carrier address 10 (data carrier type with 32 byte block size): Host: BIS C-60_2 Identification System: For configuring with 1.) Process subaddresses of the output buffer in the 2.) Process subaddresses of the input buffer in the double bit header...
  • Page 20 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Examples for protocol sequence Example No. 6 Write 16 bytes starting at data carrier address 20 (data carrier type with 32 byte block size): Host: BIS C-60_2 Identification System: For configuring with 1.) Process subaddresses of the output buffer in the 2.) Process subaddresses of the input buffer in the double bit header...
  • Page 21 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Examples for protocol sequence Example No. 7 Host: Host: Store Mixed Data 5.) Process subaddresses of the output buffer: 6.) Process subaddresses of the input buffer: Access program (continued) For configuring with double bit header and 8-byte buffer size!
  • Page 22 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Examples for protocol sequence Example No. 8 Read data carrier using Program No. 1 (data carrier type with 32 byte block size): Use Mixed Data Host: BIS C-60_2 Identification System: Access program 1.) Process subaddresses of the output buffer in the 2.) Process subaddresses of the input buffer in the...
  • Page 23: Read/Write Times

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Function Description Examples for protocol sequence Example No. 10 Put the relevant read/write head into ground state: Both read/write heads can be independently set to the ground state. Host: BIS C-60_2 Identification System: 1.) Process subaddresses of the output buffer: 2.) Go to ground state;...
  • Page 24: Led Display

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Read/Write Times Read times from Read times within the 1st block for dual read and compare: data carrier to processor in The indicated times apply after the data carrier has been recognized. If the data carrier is not dynamic mode yet recognized, an additional 45 ms for building the required energy field until the data carrier is recognized must be added.
  • Page 25: Mounting Head / Processor

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6002 Mounting Head / Processor Orientation of the Depending on model, the processor is equipped with a read/write head or the adapter for read/write head or offset read/write heads. Both the read/write head and the adapter can be rotated by the user by + or –90 deg.
  • Page 26 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6002-...-KL2 Installing the connection cables Make connections The BIS C-6002 processor must be opened in order to make the connections for the supply on the BIS C-6002 voltage, the digital input and the PROFIBUS connections (see 50).
  • Page 27: Interface Information / Wiring Diagrams

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6002-...-KL2 Interface Information / Wiring Diagrams Remote bus cable To insert BIS C-6002 processor into the serial PROFIBUS, terminals 1and 2 and 5 and 6 for and interfaces for the PROFIBUS-DP interface are located on the terminal block ("incoming" and "outgoing"). PROFIBUS-DP Bus station BIS C-6002 Bus station...
  • Page 28 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6002-...-KL2 Interface Information / Wiring Diagrams Wiring diagram Connection for Read/Write Head 1 for BIS C-6002 Connection for processors with Read/Write Head 2 BIS C-650 adapter Head 1 Head 2 01 = CT Present 1 02 = CT Present 2 Head 1 Head 2...
  • Page 29 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6002-...-ST11 Interface Information / Wiring Diagrams Remote bus cable To insert BIS C-6002-...-ST11 processor into the serial PROFIBUS-DP, there are the terminal for PROFIBUS-DP X2 for the PROFIBUS input and the terminal X3 for the PROFIBUS output. Bus station Bus station BIS C-6002-...-ST11 Bus station...
  • Page 30: Changing The Eeprom

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6002 Changing the EEPROM Changing the To replace the EEPROM, open up the processor as described on EEPROM in the BIS C-6002 processor Be sure before opening that the unit is discon- nected from power..
  • Page 31 89/336/EEC (EMC-Guideline) and the EMC Law. Testing in our EMC Laboratory, which is accredited by the DATech for Testing of Electromagnetic Compatibility, has confirmed that Balluff products meet the EMC requirements of the Generic Standard EN 61000-6-4 (Emission) and EN 61000-6-2 (Noise Immunity).
  • Page 32: Ordering Information

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6002 Ordering Information BIS C-6002-028-_ _ _-03-_ _ _ Ordering Code Balluff Identification System Type C Read/Write System Hardware Type 6002 = plastic housing, PROFIBUS-DP Software-Type 028 = PROFIBUS-DP with memory optimization...
  • Page 33 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6022 Mounting Processor Mounting the The processor is mounted using 4 M4 screws. BIS C-6022 processor Head 2 Head 1 ca. 20 BIS C-6022 Opening the processor / Interface information Opening the To set the PROFIBUS-DP address, activate or deactivate the internal termination resistor, set BIS C-6022 the compatibility mode or to change the EEPROM, you must open up the BIS C-6022 proces-...
  • Page 34 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6022 Interface Information / Wiring Diagrams To insert BIS C-6022 processor into the serial PROFIBUS and to connect the supply voltage and the digital input, the cables have to be connected to the terminals of the processor. For more details regarding the wiring see the following .
  • Page 35 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6022-...-ST10 Interface Information / Wiring Diagrams Wiring diagram for Head 2 Head 1 X1, supply voltage, digital input, and BIS C-6022-...-ST10 CT Present outputs processor .unction X2, PROFIBUS output .unction Head 1 X3, PROFIBUS input Head 2 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1...
  • Page 36 All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 BIS C-6022 Changing the EEPROM Changing the To change the EEPROM, open the processor as described on EEPROM in the BIS C-6022 processor Be sure before opening that the unit is disconnected from power. Head 2 Head 1 To avoid damaging the EEPROM, please observe the requirements for handling...
  • Page 37 89/336/EEC (EMC-Guideline) and the EMC Law. Testing in our EMC Laboratory, which is accredited by the DATech for Testing of Electromagnetic Compatibility, has confirmed that Balluff products meet the EMC requirements of the Generic Standard EN 61000-6-4 (Emission) and EN 61000-6-2 (Noise Immunity).
  • Page 38: Appendix, Ascii Table

    All manuals and user guides at all-guides.com C60_2-028_823024_0401-e.p65 Appendix, ASCII Table Deci- Control Deci- Control Deci- Deci- Deci- Deci- ASCII ASCII Hex ASCII Hex ASCII Hex ASCII Hex ASCII Code Code...

Table of Contents