Heating zones of the same
side (Such as the first and
the second zone) would
display "u" .
Fan motor sounds
abnormal.
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and damages to the induction hob.

9. Installation

9.1 Selection of installation equipment

Cut out the work surface according to the sizes shown in the drawing.
For the purpose of installation and use, a minimum of 5 cm space shall be preserved around the hole.
Be sure the thickness of the work surface is at least 30mm. Please select heat-resistant work
surfacematerial to avoid larger deformation caused by the heat radiation from the hotplate.As shown
below:
L(mm)
W(mm)
590
520
Under any circumstances, make sure the Induction cooker hob is well ventilated and the air inlet and
outlet are not blocked. Ensure the induction cooker hob is in good work state. As shown below
Note: The safety distance between thehotplate and the cupboard above thehotplate should be at
least 760 mm.
The power board and
the display board
connected failure;
The display board of
communicate part is
damaged.
The Main board is
damaged.
The fan motor is
damaged.
H(mm)
D(mm)
60
56
22
restart unit.
Check the connection.
Replace the display
board.
Replace the power board.
Replace the fan.
A(mm)
B(mm)
560+4
490+4
+1
X(mm)
50 mini
+1