Page 5
O (Open) O (Open) Tsmo SLDO FSTS FSTS Tsmc SLDc C (Close) C (Close) Finecorsa di chiusura SWC (C) Closing limit stop SWC (C) Anticipa. Endschalter Schließen SWC (C) Fin de course de fermeture SWC (C) Anticipate. Fin de carrera de cierre SWC (C) Vorverlegung.
Page 6
Giunzione. Coupling. N° 3 fili sez. 1. Verbindung. No. 3 cables sect. 1. Joint. 3 Drähte Durchschnitt 1. Unión. N. 3 fils - sect. 1. Sztukowanie 3 cables sección 1 mm. 3 kable o przekr. 1 mm 1 Steurgehäuse CP.LADY 2 Fotozelle vom Sender 3 Fotozelle vom Empfänger 4 Blinker VE.L650...
Page 7
Display OFF Power ON v1. 0 5 Firmware Ver. (3s) 8888 Inst Boom Diagnostic ---0 0--- IBCA Mode Norm Parc fsts sldo ltca sldc tst1 tsmo tstm tsmc cvar lbar aopf seav RADI sear OPen saso Clse sasc AUX1 n TX AUX2 nman...
Page 8
Schema menu di programmazione - Menu programming layout Diagramm Programmiermenü - Menu de programmation Menú de la carta de programación - Układ menu programowania Nman 0012 3456 MACI 2 Cycle AUTO PUSH OPEN/CLOSE RE-ENTER CODE 0000 9000 9C5a conf CODE Display OFF Inst Legenda...
Page 9
- 24V + AUX2 BLINK 2xDA.BT2 (Optional) (Optional) CP.LADY LED 2 24Vdc 500 mA LED 1 - 24V + SA.24V LIGHT LAMP. 24Vdc 24Vdc AUX2 BLINK 100÷250 Vac...
- Enter the INST menu - Verify that the parameter BOOM is correct: 7-8 for all VE.650 models (factory settings). - Set the barrier position by means of the menu POS, by default the barrier is set as RIGHT BARRIER - Enter the menu AUTO, confirm with <PG>...
Page 12
Every utilization different from the one described in this instruction manual is not allowed and voids the manufacturer warranty. We would like to remind you that if you register on the site www.beninca.com you will have access to the technical documentation updated for all the Benincà...
Page 13
7) SELECTION OF SPRING AND THE ACCESSORIES FOR USE Based on the length of the shaft and the type of accessories installed, before proceeding to tensioning the spring, the correct type of springs must be chosen. VE.650 Length of the rod (m) 1 yellow...
TERMINAL BLOCK M2 P.P. Step by step Input for step by step command (N.O. contact) . CLOSE Close Input for close command (N.O. contact) . OPEN Open Input for open command (N.O. contact), It is possible to connect a timer for programmed openings. PHOT Photocell Input for photocells enabled during opening and closing phase (N.C.
Page 15
14.2) PARAMETERS (PAR) MENU FUNCTION MIN-MAX-(Default) MEMO Automatic closing time. Enabled only with logic “TCA”=ON. 1-240-(20s) At the end of the set time, the control unit commands a closing maneuver . FSTS Adjusts the opening and closing speed of the barrier (standard speed, before the slowdown phase). 50-99-(99) sldo Adjusts the slowdown speed of the barrier during the opening phase* (Fig.8 -slow Open).
Page 16
Enables or disables rapid closing On: rapid closure is enabled. With open bar, or in the opening phase, the activation of the photocell (OFF) causes the automatic closure 3sec after the total opening of the gate. It is activated only with TCA:ON Off: rapid closing disabled.
Page 17
14.5) CYCLES NUMBER (NMAN) Displays the number of complete cycles (open+close) carried out by the automation. When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>> <PG> 3456: made 123.456 cycles.
The logic LOC can be set in two ways: ON: the SLAVE barrier can accept a local command and execute an opening/closing maneuver with no effect on the MASTER barrier. OFF: the SLAVE barrier do not accept any local command and so it will replicate exclusively the behavior of the MASTER barrier. A SLAVE barrier with LOC set to ON can be useful in case it is occasionally necessary the partial opening of a passage which is usually managed by two synchronized barriers, since that a step by step command (or OPEN/CLOSE) given to the SLAVE will have effect only on this last one, while all the other commands given to the MASTER will be replicated by the SLAVE.
Page 19
VE.650 Libro istruzioni per l’utilizzatore User’s handbook Handbuch für den Verbraucher Norme di sicurezza Safety rules • Non sostare nella zona di movimento delle ante. • Do not stand in the movement area of the gate. • Non lasciare che i bambini giochino con i comandi o in prossimità delle •...
Need help?
Do you have a question about the VE.650 and is the answer not in the manual?