5
Read Out the Adjustment Data
(1) Click on MCUT22SPio_E.exe to start the program.
The following screen will open:
(2) Click on [Rewrite Mode].
The following screen will open:
Note: If the following error message is displayed, click on
[OK]. Then click on Setup for COM port settings.
See the reference "SETUP screen (default settings)"
described at the end of the procedures.
(3) Set the Main Power switch of the PDP to ON.
(4) After the message "It succeeded in starting in "rewrite
mode". is displayed, click on [Exit].
(5) The MAIN MENU returns.
5
6
(6) Click on [EEPROM]. The following screen will open:
(7) Click on the following address indication to select it:
(8) Click on [Read]. The Save As window will open.
Designate a filename (extension: .eep) then click on
Save.
When reading is completed, the figure becomes 100%. The
Reading Completed window is displayed. To display the
content of the data that have been read out, click on Yes. If
displaying is not required, click on No.
PDP-507CMX
6
7
7