Troubleshooting

Power will not turned on.
No sound.
No sound is output to MASTER OUTPUT
or SPEAKER terminals from microphone.
No sound from wireless microphone.
Sound is heard in monaural.
Sound is distorted.
No sound from MIC4.
Wireless remote control does not function.
Signal of the ST2 can not be recorded.
12
• Is the power cord unplugged?
• Is the curcuit breaker working? (See page 7.)
• Does the EMG indicator turn off? (See pages 4 and 7.)
• Does the PROTECTION indicator turn off? (See page 4.)
• Has the ASSIGN switch been set to OFF? (See page 8.)
• Has the MIC GROUP knob been set to – ? (See page 5.)
• Is the channels of microphone and tuner unit matching?
And does the RF/SIGNAL indicator light on when the microphone
is turned on? (See page 9.)
• Is the antenna connected correctly?
Has the MODE switch been set to STEREO? (See page 8.)
Is the CLIP indicator lighting on? (See page 4.)
Has another microphone been connected to MIC4 terminal
on the front panel?(See page 4.)
• Has a plug been connected to CONTROL-S input terminal
on the rear panel?(See page 6.)
• Are the remote control batteries dead?(See page 8.)
Signal from ST2 does not output to REC OUTPUT. (See page 5.)