Page 1
S AND OPERATOR S MANUAL Diesel Engine Generator IDG3 CAUTION Do not operate the Generator, or any other appliance, before you have read and understood the instructions for use and keep near for ready use. IDG3100M X750-028 35 0 X750801-730 0...
Page 3
Introduction Thank you for purchasing this Shindaiwa Soundproof Diesel Engine Generator. This manual has been created to ensure safe usage of this generator. Be sure to read this manual before operation. Improper operation/handling of this generator will result in an accident or malfunction.
1. Safety Precautions WARNING: EXHAUST GAS POISONING Do not operate the generator in poorly ventilated areas such as indoors or tunnels because the exhaust gas of the engine contains substances that are harmful to human health. 1. WARNING: ELECTRIC SHOCK ...
Page 6
CAUTION: BURNS Do not touch the engine or surrounding parts while the generator is operating or immediately after the engine has stopped because they are still extremely hot. Do not open the radiator cap while operating the generator or immediately after stopping the engine.
BURNS ( Part no. X505-007620 ) BURNS ( Part no. X505-007640 ) INJURY ( Part no. X505-007630 ) 2. Specifications Model IDG3100M Generator Type Multipolar revolving magnetic field type 2. Excitation Magnetic Voltage Adjustment Type Inverter Rated Frequency...
3. Applications Power source for electric tools Power source for lighting equipment Power source for household appliances CAUTION: PROPERTY DAMAGE Some computers, devices having a microcomputer, and precision equipment are voltage sensitive. Please consult with the authorized distributor where this generator was purchased or one of our sales offices if using this generator to power such devices or equipment.
5. Equipment 5-1. Idle Control Switch Output Switch Idle Control This generator is equipped with an energy-saving Switch ("ECO") function that controls the engine speed in accordance with the capacity of the device using the generator in order to reduce noise and fuel consumption.
5-5. Monitor Lamps WARNING: ELECTRIC SHOCK/INJURY Be sure to always stop the engine before performing any check or maintenance. Do not open any doors during operation. An open door could result in being pinched or caught in moving parts such as the cooling fan and belt.
(3) OIL PRESS (Oil Pressure) Monitor Lamp The OIL PRESS monitor lamp lights up and the engine automatically stops if the engine oil level becomes low during operation causing the oil pressure sensor to operate. The indicator turns off after the generator is stopped. If you can confirm the cause of the stop, restart the engine.
(1) Locking the Wheel Lock Lift up the wheel lock lever in the direction of arrow . Move the generator forward and back, and move the wheel lock lever in the direction of arrow until you hear a click indicating that the wheel is locked. Check that the generator cannot move.
<Note> The oil level cannot be accurately checked if the generator is inclined. Operating the generator when the oil level exceeds the maximum level (H) can damage the engine. Maximum Level (H) Effective Oil Selecting the Engine Oil Capacity Use oil for diesel engines with a proper viscosity that Minimum Level (L)
<Note> Use good quality soft water such as suitable tap water for the coolant. Use a long-life coolant (LLC) in order to prevent freezing and rust. (This generator is filled with coolant having a 30%-LLC (Besco LLC Super Type E) mixing ratio when shipped from the factory.) ...
6-5. Battery Inspection WARNING: EYE/SKIN INJURY Wear rubber gloves and other protective wear to protect eyes, skin and clothing from the battery fluid which contains diluted sulfuric acid. If battery fluid contacts eyes or skin, wash out immediately with an ample amount of clean water, and be sure to receive medical treatment.
7. Operating Procedures 7-1. Starting the Engine WARNING: EXHAUST GAS POISONING 4. Do not operate the generator in poorly ventilated areas such as indoors or tunnels because the exhaust gas of the engine contains substances that are harmful to human health. WARNING: FIRE ...
<Note> Once the engine has started, do not turn the Starter switch to the "START" position. Check that the 50 Hz or 60 Hz frequency is flashing. monitor lamp Operate the generator for approximately five minutes to warm it up. Idle Control Switch Close Fuel Lever...
8. Generator Operation WARNING: ELECTRIC SHOCK Make sure that all doors and covers are closed during operation. 5. Do not touch this generator during operation if it or your body is wet. Do not insert any pins, wire or other metal object into the output outlet. ...
<Note> A maximum current of 15 A is output from a single 15-A outlet. A maximum current of 30 A is output from the single 30-A outlet. The total maximum current output from all AC outlets is 31 A. 8-2.
9. Inspection/Maintenance WARNING: ELECTRIC SHOCK/INJURY 6. Be sure to always stop the engine before performing any check or maintenance. Do not open any doors during operation. An open door could result in being pinched or caught in moving parts such as the cooling fan and belt.
Inspection Period Pre-Operation Inspection Item Every Every Every Inspection Every Every 50th hour 1,000 2,000 hours hours hours hours hours Fuel (Check/Add) Engine Oil (Check/Add) 2nd time 1st time Engine Oil (Replace) and after 2nd time 1st time Oil Filter (Replace) and after...
<Note> For the types of engine oil, refer to "6-1. Engine Oil Inspection ". Replace the packing with new packing every time you replace the oil. Packing part no.: 6C090-58961 (Kubota part no.) After tightening the oil drain plug, be sure to always operate the engine for a few minutes and check that there is no oil leakage.
<Note> When installing the air cleaner cap, install with the arrow of the "TOP" label facing upwards. Clean within a shorter period if using in an area with a large amount of dust. Air cleaner element part no.: 1G659-11221 Air Cleaner Cap (Kubota part no.) ...
9-6 Cooling Water (Replace) Every 2,000 hours or every two Radiator Cap Check Plate Replace years <Cooling water capacity is approx. 2.2 L (including the sub tank capacity of approx. 0.6 L).> Remove the check plate. Remove the radiator cap. Water Inlet Remove the water drain plug.
Remove the battery. (Refer to "6-5. Battery Inspection ".) Replace the engine oil. (Refer to "9. Inspection/Maintenance".) Drain the fuel from the fuel tank and fuel filter. (Refer to "9. Inspection/Maintenance".) Remove the engine key and store carefully in a secure location. Clean the entire generator, and store in a dry and dust-free location, with it covered or otherwise protected.
Page 27
Symptom Possible Causes Remedy 1. Battery is depleted 1. Recharge battery Starter motor does not 2. Battery is deteriorated 2. Replace battery start 3. Fuse has blown 3. Repair 1. Close the fuel lever 1. Open the fuel lever 2. Low fuel 2.
Need help?
Do you have a question about the IDG3100M and is the answer not in the manual?
Questions and answers