BSH5000 Operation manual Chapter 1 Introduction Chapter 1 Introduction The dry bath incubator is controlled by sophisticated software, which can be widely used for the preservation and reaction of samples, the amplification of DNA, the pre-denaturation of the electrophoresis, blood serum coagulation and a variety of laboratory procedures.
BSH5000 Operation manual Chapter 3 Overview Chapter 3 Overview This chapter focuses on the introductions of the structure, keypads and key-functions of the instrument, as well as preparatory work prior to initial operation. 1. Structure overview Transparent cover Dual Block chamber Housing Control panel On/Off button...
BSH5000 Operation manual Chapter 3 Overview 2. Keypads ℃ ℃ Temp. Temp. Time Time External External Start Start Stop Stop 3. Display Down key: Used in both time and temperature mode to decrease the setting. Up key: Used in both the time and temperature mode to increase the setting.
BSH5000 Operation manual Chapter 4 Operation Guide Chapter 4 Operation 1. Temperature and time setting Press the On/Off switch to power on the instrument. The instrument performs a self test followed by an alarm to signal that the product is ready for use. b) After about 3 sec.
BSH5000 Operation manual Chapter 4 Operation Guide Timer Operation (Advanced) The default setting of the instrument is designed so that the heater will continue to hold the set temperature even once time has expired and “oVEr” is showing on the time display.
Page 9
BSH5000 Operation manual Chapter 4 Operation Guide Thermometer Olefin oil Cone-shaped well Fig. a c) Press “Stop” key and the key simultaneously for 3 seconds, the bath enters into the temperature calibration interface. At this point, “ ” is displayed, indicating entry into temperature calibration mode.
Page 10
BSH5000 Operation manual Chapter 4 Operation Guide d) Once the “Start” button is pressed, Then the instruments will the automatically begin to heat to 100°C. Once 100°C is shown on the display (this may take up to 30 minutes) and held as constact, the decimal begins to flash. Please wait 20 minutes and then check the actual value from thermometer.
Page 11
BSH5000 Operation manual Chapter 4 Operation Guide Once held constant at 40.0 °C, the decimal digit begins to flash. Note: It is important to allow 20 minutes for the temperature to equilibrate before making any adjustment to the temperature. After 20 minutes, Press the “Stop” key to display the temperature value of External Probe.
BSH5000 Operation manual Chapter 4 Operation Guide 4.Temperature control by external sensor a) Insert the external temperature probe into a well of the dry bath or directly into a sample tube. b) Press and hold “Stop”, then simultaneously press and hold “” for 3 seconds, the external indicator light goes on to indicate that it has entered into the temperature control mode of external sensor.
BSH5000 Operation manual Chapter 5 Failure Analysis and Troubleshooting Chapter 5 Failure Analysis and Troubleshooting Problems and actions Common problem Possible cause Action(s) No power on the main Check power supply power plug plugged properly Faulty fuse Change fuse display screen On/Off button broken Change button...
BSH5000 Operation manual Annex Annex:Wiring Diagram ( ) for reference only POWER MAIN Sw itch BOARD BOARD J4 H eat J2 PT1 00 U SB 1 U S B J4 PT1 00 0 H EA T U SB PT1 00 0 Block CONN BOARD —...