Mitsubishi Electric PUD-SWM60VAA Service Manual page 56

Air to water heat pump units
Hide thumbs Also See for PUD-SWM60VAA:
Table of Contents

Advertisement

SW2 setting
The number of defrost cycles
0 to FFFE
ON
1
2 3 4 5 6
The input current of outdoor unit
ON
0 to 500
1
2 3 4 5 6
The LEV-B opening pulse
ON
0 to 500
1
2 3 4 5 6
The U9 error detail history (latest)
ON
1
2 3 4 5 6
The DC bus voltage
ON
100 to 1023
1
2 3 4 5 6
The communication demand capacity
ON
0 to 255
1
2 3 4 5 6
The error postponement code history (2)
ON
of outdoor unit
1
2 3 4 5 6
The error postponement code history (3)
ON
of outdoor unit
1
2 3 4 5 6
The error history (3) (Oldest)
ON
Alternate display of abnormal unit
number and code
1
2 3 4 5 6
The error thermistor display
When there is no error thermistor,
ON
"–" is displayed.
1
2 3 4 5 6
The operation frequency when the last
error occurred
ON
0 to 255
1
2 3 4 5 6
OCH756
Display detail
The black square (
Explanation for display
0 to FFFE (in hexadecimal notation)
(When more than FF in hex (255 in decimal), the
number is displayed in order of 163's and 162's, and
161's and 160's places.)
Example: When 5000 cycles
0.5 s
0 to 500
(When it is 100 or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
0 to 500
(When it is 100 pulse or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
Description
Normal
Overvoltage error
Undervoltage error
Input current sensor error
L
-phase open error
1
Abnormal power synchronous signal
PFC error
(Overvoltage/Undervoltage/Overcurrent)
PFC/IGBT error (V-type)
Undervoltage
• Display examples for multiple errors:
Overvoltage (01) + Undervoltage (02) = 03
Undervoltage (02) + Power-sync signal error (08) = 0A
L
phase open error (04) + PFC/IGBT error (20) = 24
1
100 to 1023
(When it is 100 V or more, hundreds digit, tens
digit and ones digit are displayed by turns.)
0 to 255
When the communication demand is not set, "100" is
displayed.
Postponement code display
Blinking: During postponement
Lighting: Cancellation of postponement
"00" is displayed in the case of no postponement.
Postponement code display
Blinking: During postponement
Lighting: Cancellation of postponement
"00" is displayed in the case of no postponement.
When no error history, "0" and "– –" are displayed by
turns.
3: Liquid pipe temperature (TH3),
Suction pipe temperature (TH32)
4: Discharge pipe temperature (TH4)
6: 2-phase pipe temperature (TH6)
7: Ambient temperature (TH7)
8: Heat sink temperature (TH8)
33: Comp. surface temperature (TH33)
0 to 255
(When it is 100 Hz or more, hundreds digit, tens digit
and ones digit are displayed by turns.)
Example: When 125 Hz
0.5 s
56
) indicates a switch position.
2 cycles
0.5 s
2 s
9
C4
Display
00
01
02
04
08
display
10
20
display
display
display
display
0.5 s
2 s
1
25
Unit
0.1 A
Pulse
Code
V
%
Code
Code
Code
Code
Hz