Summary of Contents for Level Pro VIEWSONIC2 Series

  • Page 1 VIEWSONIC2 SERIES Manual VIEWSONIC2 Series Operating Instructions TANK LEVEL FEET 14.2 2 1. 100% TIME 2 1 : 4 3 +/max/min -/tank alarm...
  • Page 2: Insert Battery

    VIEWSONIC2 SERIES Manual 1.1. Insert Battery Figure 1 1) Open the battery door, remove the battery box; 2) Insert 6 x AAA 1.5V alkaline batteries into the battery box, observing the correct polarity. Then put back the battery box according to the marking direction.
  • Page 3: Initial Setup

    VIEWSONIC2 SERIES Manual 1) The sensor is not installed at a level horizontal position. 2) The sensor is too close to the Tank wall. 3) There are solid objects in the tank. 4) The transmitter bottom is dipped in the water (or other liquids in tank) Note: Even though it works fine in occasional water splash or dew, this product is not completely water proof in heavy rain.
  • Page 4 VIEWSONIC2 SERIES Manual 2. OVERVIEW The following illustration shows a normal LCD display for description purposes only. 1. Value Display Area 2. Tank Temperature and Water Level TANK LEVEL FEET Icon 3. Liquid Level Units HI AL 4. Tank Temperature Unit (ºC/ºF)
  • Page 5 VIEWSONIC2 SERIES Manual The Range is defined as the distance from the bottom of the tank transmitter to bottom of your tank. Minimum Range 18" Maximum Range 49 ft. Display of "0.00" and full tank icon flashes (Figure 9). Press...
  • Page 6: Set Temperature Unit

    VIEWSONIC2 SERIES Manual MINUTE: Minute value will flash. Press key to increase or decrease minute value. When minute +/max/min -/tank value is set press key to set temperature unit (Figure 12). TANK TANK FULL FULL TIME TIME +/max/min -/tank alarm...
  • Page 7 VIEWSONIC2 SERIES Manual 3.5 Check and Reset MIN/MAX Value In normal display mode press key once to check the max value of indoor temperature and tank level or tank +/max/min temperature (Figure 15). TANK LEVEL FEET HI AL EMPTY LO AL...
  • Page 8: Set Time Alarm

    VIEWSONIC2 SERIES Manual TANK LEVEL TANK LEVEL FEET FEET HI AL HI AL EMPTY EMPTY LO AL LO AL FULL FULL TIME TIME +/max/min -/tank alarm +/max/min -/tank alarm Figure 18 +/max/min 3.6 Tank Level and Tank Temperature Switch In normal display mode, press...
  • Page 9 VIEWSONIC2 SERIES Manual Press key 3 seconds to set alarm hour. Alarm hour will flash. Press key to increase or +/max/min -/tank decrease alarm hour (Figure 22). TANK LEVEL TANK LEVEL FEET FEET HI AL HI AL EMPTY EMPTY LO AL...
  • Page 10 VIEWSONIC2 SERIES Manual key to set tank level low alarm. The previously set tank level low alarm value After tank level high alarm is set press will flash. Press key to increase or decrease low alarm value (Figure 26). +/max/min...
  • Page 11: Default Value

    VIEWSONIC2 SERIES Manual Empty Alert When water level is less than 20% of tank depth, the icon will display (Figure 30). EMPTY TANK LEVEL FEET HI AL EMPTY LO AL FULL TIME +/max/min -/tank alarm Figure 30 4. DEFAULT VALUE 1.
  • Page 12 VIEWSONIC2 SERIES Manual 6. Faults and Handling Faults Causes Handling Level meter does not work. Power supply is not well connected. Inspect power line 1. Power supply is not well connected. Level meter does not display data. 1. Inspect power line 2.