Kallista P23052-CR Installation Instructions Manual page 3

Thermostatic valve trim
Table of Contents

Advertisement

Available languages

Available languages

INSTALLATION INSTRUCTIONS
NOTE: Check the finished wall surface as related to the graphics on the plaster guard.
‰ Select the correct length valve stem adapter and screw for your application. Refer to the information
stamped on the plaster guard to verify the wall thickness.
‰ Thin wall - 3/16" (5 mm) to 9/16" (14 mm): Use the 7/8" (22 mm) (short) valve stem adapter, stamped "3"
on the plaster guard, and the 1-3/8" (35 mm) screw.
‰ Standard wall - 9/16" (14 mm) to 1-1/16" (27 mm): Use the 1-3/8" (35 mm) (medium) valve stem adapter,
stamped "1" on the plaster guard, and the 1-3/4" (44 mm) screw.
‰ Thick wall - 1-1/16" (27 mm) to 1-9/16" (40 mm): Use the 1-7/8" (48 mm) (long) valve stem adapter,
stamped "2" on the plaster guard, and the 2-3/8" (60 mm) screw.
‰ Remove and discard the plaster guard from the valve.
‰ Place the spline adapter over the valve stem.
‰ Set the valve stem adapter over the spline adapter. Do not completely press or screw the valve stem
adapter into place until instructed to do so.
1491208-2-A
3 of 16
1. INSTALL THE VALVE STEM ADAPTER
Thermostatic Valve Trim
Questions? Problems? For additional assistance, please contact KALLISTA's Customer
Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.