Code
Parameter
D.051
Offset for maximum speed
D.060
Number of switch-off sequences for
the safety cut-out
D.061
Number of flame sequence control
faults
D.064
Average ignition time
D.065
Maximum ignition time
D.067
Remaining burner anti-cycling time
D.068
Unsuccessful ignitions at 1st attempt
D.069
Unsuccessful ignitions at 2nd at-
tempt
D.071
Target value maximum heating flow
temperature
D.072
Overrun time for the heating pump
after cylinder post-heating
D.074
Anti-legionella function
D.075
Maximum charging time for the
domestic hot water cylinder
D.076
Product-specific number
D.077
Limit on cylinder charging output
D.078
Cylinder charging temperature limit
(target flow temperature in cylinder
charging mode) in °C
D.080
Operating hours of the burner in
heating mode
D.081
Operating hours of the burner for
domestic hot water generation
D.082
Number of burner start-ups in heat-
ing mode
D.083
Number of burner starts in domestic
hot water mode
D.084
Maintenance indicator: Number of
hours until the next maintenance
D.085
Minimum output of the product
D.090
Status of the eBUS control
D.091
Status of DCF with outdoor temper-
ature sensor connected
D.093
Unit variant setting (DSN)
D.094
Delete fault history
D.095
Software version of PeBUS compon-
ents
D.096
Default setting
0020261389_03 ecoTEC plus Installation and maintenance instructions
Values or explanations
−990 to 0 rpm
Number of shutdowns
Number of unsuccessful ignitions in the last attempt
s
s
min
Number of unsuccessful ignitions
Number of unsuccessful ignitions
30 to 80 ℃
0 to 600 s
Thermal disinfection is carried out every 24 hours
0 = Inactive
1 = Active
20 to 90 min
Unit variant display (DSN)
Adjustable cylinder charging output in kW
55 to 85 ℃
h
h
Number of burner start-ups (x 100)
Number of burner start-ups (x 100)
0 to 3,000 h
"-" to deactivate the function
kW
1 = Detected
2 = Not detected
0 = No reception
1 = Reception
2 = Synchronised
3 = Valid
Adjustment range: 170 to 199
The three-digit DSN code is located on the product's
data plate.
Delete fault list
0 = No
1 = Yes
Main PCB (BMU)
PCB for the control element (AI)
Reset all adjustable parameters to factory setting
0 = No
1 = Yes
Default
User-spe-
setting
cific setting
-45
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
75 ℃
120 s
0
45 min
Not ad-
justable
Maximum
output
80 ℃
Not ad-
justable
Not ad-
justable
Not ad-
justable
Not ad-
justable
„-"
Not ad-
justable
Not ad-
justable
Not ad-
justable
0
57