Number for
Control
the basic
system
diagram
0020253235
VRC 700
system
control
0020253236
Connected
vSMART
control
Note
The example of a basic installation diagram that
is shown in the appendix does not replace any
correct and expert system planning. (→ Page 66)
The settings for the internal pump are made at the factory.
Ensure that there is sufficient dimensioning for the
connections and the domestic hot water cylinder.
(→ Page 23)
Connect the external prioritising diverter valve to the plug
X13 on the main PCB.
In order to control the cylinder's post-heating, connect
a VR 10 temperature sensor or a thermostat to the plug
that is connected to the main PCB.
Wiring diagram (→ Page 64)
To start up the prioritising diverter valve, it is not necessary
to set a diagnostics code. It is directly actuated by the pro-
duct's main PCB.
7.2.2
Basic system diagram type 2: Decoupled
heating circuit plus one directly connected
domestic hot water cylinder
1
Wall-hung boiler with
internal pump
2
Prioritising diverter
valve
3
Low loss header or
plate heat exchanger
In order to use this basic diagram type, ensure that the
minimum flow volumes are guaranteed for the operation.
(→ Page 8)
The product can control a decoupled heating circuit and a
directly connected domestic hot water cylinder.
0020261389_03 ecoTEC plus Installation and maintenance instructions
Number
Carrying out the
of cir-
wiring
cuits
1
Contact customer
service.
1
Contact customer
service.
1
2
6
3
4
5
4
External pump for the
decoupled heating
circuit
5
Heating circuit
6
Domestic hot water
cylinder
Number for
Control
the basic
system
diagram
0020253238
VRC 700
system
control
0020253239
VRC 700
system
control
VR 70 multi-
functional
module
0020259027
VRC 700
system
control
VR 71 multi-
functional
module
The settings for the internal pump are made at the factory.
Ensure that there is sufficient dimensioning for the
connections and the domestic hot water cylinder.
(→ Page 23)
Downstream of the low loss header, select a heating
pump that is appropriate for the installation.
Connect the external pump for the decoupled heating
circuit to the plug X16 for the main PCB.
Connect the external prioritising diverter valve to the plug
X13 on the main PCB.
Connect the temperature sensor for the low loss header
to plug X41 on the main PCB. Observe the instructions
for the low loss header.
In order to control the cylinder's post-heating, connect
a VR 10 temperature sensor or a thermostat to the plug
that is connected to the main PCB.
Wiring diagram (→ Page 64)
Set diagnostics code D.026 to 2.
Overview of diagnostics codes (Validity: VU 446/5-5 (H-
GB) OR VU 606/5-5 (H-GB)) (→ Page 55)
7.2.3
Basic system diagram type 3: Decoupled
heating circuit plus one decoupled domestic
hot water cylinder
1
2
3
1
Wall-hung boiler with
internal pump
2
Low loss header or
plate heat exchanger
Number
Carrying out the
of cir-
wiring
cuits
1
Inform Customer
Service.
2
Inform Customer
Service.
>3
Inform Customer
Service.
6
4
5
3
External pump for the
decoupled heating
circuit
21