Whirlpool AKR 350 Instructions Manual page 3

Built-in gas hob
Table of Contents

Advertisement

Available languages

Available languages

ASSEMBLY
After having cleaned the perimeter surface, apply the supplied gasket to the hob as shown in the figure.
Position the hob in the worktop opening made respecting the dimensions indicated in the Instruction.
NOTE: the power supply cable must be long enough to permit its upward extraction.
To secure the hob, use the brackets (A) provided with it. Fit the brackets into the relevant bores shown by the arrow and fasten them by means of their screws in accordance
with the thickness of the worktop (see the following figures).
Top 30-50 mm
Top 20 mm
ADJUSTMENT TO DIFFERENT TYPES OF GAS
This operation must be performed by a qualified technician.
WARNING
If the appliance is intended to operate with a different gas from the gas type stated on the rating plate and information label on the top of the hob, change the injectors.
Remove the information label and keep it with the instructions booklet.
Use pressure regulators suitable for the gas pressure indicated in the Instruction.
• The gas nozzles must be changed by After Sales Service or a qualified technician.
• Nozzles not supplied with the appliance must be ordered from After Sales Service.
• Adjust the minimum setting of the taps.
NOTE: when liquid petroleum gas is used (G30/G31), the minimum gas setting screw must be tightened as far as it will go.
IMPORTANT: should you experience difficulty in turning the burners knobs, please contact the After Sales Service for the replacement of the burner tap
if found to be faulty.
REPLACING THE INJECTORS (see the injector table in the Instruction)
• Remove grids (A).
• Extract burners (B).
• Using a socket spanner of the appropriate size unscrew the injector (C), unscrew the injector to
be replaced.
• Replace it with the injector suitable for the new type of gas.
• Re-assemble the injector in (D).
• If you have a multiple crown burner use side spanner to replace the injector (E).
Before installing the hob, remember to affix the gas calibration plate supplied with the injectors in
such a way that it covers the existing information relating to gas calibration.
ADJUSTING MINIMUM GAS SETTING OF TAPS
To ensure that the minimum setting is correctly adjusted, remove the knob and proceed as follows:
• tighten screw to reduce the flame height (-);
• loosen screw to increase the flame height (+)
The adjustment must be performed with the tap in minimum gas setting position (small flame) .
• The primary air of the burners does not need to be adjusted.
• At this stage, light up the burners and turn the knobs from max position to minimum position to check flame stability.
Upon completion of adjustment, reseal using sealing wax or an equivalent material.
REFERENCE TO LOCAL REGULATIONS
Ensure that the installation and gas connections are performed by a qualified technician, following the manufacturer's instructions and in compliance with current local
safety regulations.
AFTER-SALES SERVICE
Before calling the After-Sales Service, make sure you can give the following information:
- type of fault or problem;
- exact model (written on the label affixed to the instruction/warranty);
- service number that follows the word SERVICE on the rating plate under the hob and on the label affixed to instruction/warranty;
- your complete address and phone number.
If any repairs are required, please contact an authorised After-Sales Service, as indicated in the warranty.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Akr 350 ix

Table of Contents