  • Page 1 VENTURI Compact ® User Manual D H G - H E A LT H C A R E . C O M...
  • Page 2 V E N T U R I C O M P A C T ® D H G - H E A LT H C A R E . C O M...
  • Page 3: Table Of Contents

    U S E R M A N U A L Contents Page 1. Explanation of Labels Symbols and Statements ..............2 2. Introduction ........................3 3. Important Information ......................3 Intended Use ........................3 Intended Environments ....................3 Contraindications for Use ....................3 List of Components ......................
  • Page 4: Explanation Of Labels Symbols And Statements

    V E N T U R I C O M P A C T ® 1. Explanation of Label Symbols and Statements YYYYMMDD Warning 12345 1234567890 Example of a UDI label 0 5060178 XXXXX X Refer to instruction manual YYMMDD / booklet 1234567890 Medical Devices Directive 93/42/EEC...
  • Page 5: Introduction

    Sets are available in a range of sizes according to the wound type being treated. The VENTURI COMPACT NPWT system is intended to be reusable and will benefit from careful installation and use, providing a long and effective service life. Please read and understand this document completely before applying NPWT.
  • Page 6: General Warnings, Cautions And Information

    (The supplied power adapters plug directly into the power source partly mitigating this issue). • The VENTURI COMPACT TG600/8 vacuum power unit must only be used with the approved power adapter supplied by Direct Healthcare Group (see Specification on page 12) •...
  • Page 7: How To Apply Npwt

    4.1 Getting Started NB. A Wound Care Set must be used with the VENTURI COMPACT system to carry out NPWT (see page 4 for available options). Please refer to the ‘Wound Care Set Instructions for Use’ leaflet (supplied with Wound Care Set) for dressing application and setup.
  • Page 8: Operation Guidelines

    The power unit will lock again 1 minute after last button operation. Please note that when running, the VENTURI COMPACT power unit must be unlocked before it can be returned to stand-by mode, i.e. the power unit cannot be put into stand-by mode when the is displayed on the screen.
  • Page 9: Operation Controls

    U S E R M A N U A L power unit can also be placed in the carry cases provided. In all instances the power unit/canister assembly should be kept upright during use to ensure correct operation - the power unit will display a warning if the unit is over tilted. Please take care when transporting the device not to drop the system onto a hard surface, bend the canister connector or pull on the dressing tube excessively.
  • Page 10: User Selectable Functions

    V E N T U R I C O M P A C T ® *UNLOCK / LIGHT The power unit will automatically lock 1 minute after last button operation when running to prevent inadvertent operation of button functions (except MUTE), as indicated by on the display screen.
  • Page 11: Care And Maintenance

    6. Care and Maintenance 6.1 Power Unit Always disconnect the VENTURI COMPACT power unit from the power adapter and the power adapter from the power source before carrying out maintenance, repairs, servicing or cleaning. Check all electrical connections and power cord for signs of excessive wear. The power unit / power adapter can be wiped down with detergent or disinfectant solution or wipe*.
  • Page 12: Transport And Storage

    V E N T U R I C O M P A C T ® 6.4 Transport and Storage Handle with care. Please report instances of damage or impact to Direct Healthcare Group Service Department. –25 °C without relative humidity control; and +70 °C at a relative humidity up to 93 %, non-condensing.
  • Page 13: Technical Specifications

    10245 The above mains adapters are considered part of the ME equipment. The VENTURI COMPACT power unit must only be used with the specific external power adapter as supplied by Direct Healthcare Group. EXPECTED SERVICE LIFE: The expected service life of the medical device and its ACCESSORIES is five years.
  • Page 14 IEC 60601.1 3rd edition Medical electrical equipment safety and essential performance IEC 60601.1.11 Home healthcare environment 8.4 Manufacturer’s Guarantee The VENTURI COMPACT power unit is covered by a 24 month manufacturer’s guarantee. D H G - H E A LT H C A R E . C O M...
  • Page 15 U S E R M A N U A L 8.5 EMI/EMC Statement and Manufacturer’s Declaration This equipment has been tested and found to comply with the limits of EN 60601-1-2. These limits are designed to provide reasonable protection against harmful interference in both a medical and residential environment.
  • Page 16 V E N T U R I C O M P A C T ® Declaration – Electromagnetic Emissions Guidance and Manufacturer’s Declaration: Electromagnetic Emissions (IEC 60601-1-2) Emissions Test Compliance Electromagnetic Environment - Guidance RF emissions Class B CISPR 11 The VENTURI systems are suitable for use in all establishments, including domestic establishments Harmonics emissions...
  • Page 17 U S E R M A N U A L Declaration – Electromagnetic Immunity Guidance and Manufacturer’s Declaration: Electromagnetic Immunity (IEC 60601-1-2) IEC 60601 Test Electromagnetic Immunity Test Compliance Level Level Environment - Guidance 3 V rms 3 V rms Field strengths from fixed RF 150 kHz ~ 80 MHz transmitters as determined by...
  • Page 18 V E N T U R I C O M P A C T ® Every care has been taken to ensure that the information contained in this manual was correct at the time of going to press. However, Direct Healthcare Group reserves the right to modify the specification of any product without prior notice in line with a policy of continual product development.
  • Page 19 U S E R M A N U A L Notes D H G - H E A LT H C A R E . C O M...
  • Page 20 PRESSURE ULCER PREVENTION SAFE MOVING & HANDLING SPECIALIST THERAPIES BATHROOM SAFETY RENTAL & SERVICE SOLUTIONS Direct Healthcare Group Ltd Withey Court, Western Industrial Estate Caerphilly, United Kingdom CF83 1BF T: +44 (0) 800 043 0881 F: +44 (0) 845 459 9832 E: info@directhealthcaregroup.com Talley Group Ltd Premier Way...