Majestic WarmMajic-II Installation Manual

Majestic WarmMajic-II Installation Manual

Epa certified woodburning fireplace
Hide thumbs Also See for WarmMajic-II:

Advertisement

Quick Links

INSTALLER: Leave this manual with party responsible for use and operation.
OWNER: Retain this manual for future reference.
Contact your dealer with questions on installation, operation, or service.
Model(s):
EPA CERTIFIED WOODBURNING
FIREPLACE
Installation and service of this appliance should be performed by
qualified personnel, Hearth & Home Technologies recommends
HHT Factory Trained or NFI certified professionals.
Installation Manual
Installation and Fireplace Setup
Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22
WARNING! Risk of Fire and/or Asphyxiation!
• Read all the instructions before starting
the installation. Follow these instructions
carefully during the installation to ensure
maximum safety and benefit.
• Comply with all minimum clearances to com-
bustibles as specified. Failure to comply may
cause house fire.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fireplace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other flammable
materials.
• Keep clothing, furniture, draperies and other flammable
materials away.
Pour demander un exemplaire en
français de ce Manuel
du propriétaire, visitez www.majes-
ticproducts.com/translations.
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WarmMajic-II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Majestic WarmMajic-II

  • Page 1 • Keep clothing, furniture, draperies and other flammable materials away. EPA CERTIFIED WOODBURNING FIREPLACE Installation and service of this appliance should be performed by qualified personnel, Hearth & Home Technologies recommends HHT Factory Trained or NFI certified professionals. Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 2: Table Of Contents

    I. Outside Air Kit ► C. Mantel and Wall Projections J. Heat-Zone-WD-C Kit (Optional) ► D. Finishing the Hearth Extension 4 Electrical Wiring E. Non-Combustible Sealant Material 9 Fireplace Setup A. Firebrick Placement B. Baffle and Blanket Placement C. Install Fascia (Fronts) 10 Reference Materials A. Chimney Components B. Accessories C. Offset Diagrams Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 3 Comments: Further description of the issues, who is responsible (Installer/Builder/Other Trades, etc.) and corrective action needed: _________________________________________________________________________________________________ ________________________________________________________________________________________________________ ________________________________________________________________________________________________________ Comments communicated to party responsible __________________________ by ______________________on _________ (Builder/Gen. Contractor) (Installer) (Date) Part # 4188-982 • Rev A • 09/19 4188-982 Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 4: Product Specific & Important Safety Information

    Hearth & Home Technologies WILL NOT warranty appli- The WarmMajic-II is Certified ances that exhibit evidence of over-firing. Evidence of to comply with 2020 particulate over-firing includes, but is not limited to: emission standards. • Warped air tube • Deteriorated refractory brick retainers • Deteriorated baffle and other interior components Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 5: Non-Combustible Materials

    V H U Y L F H R U P D L Q W H Q D Q F H F D Q F D X V H L Q M X U \ R U S U R S H U W \ G D P D J H Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 6: Getting Started

    Chimney Air Kit (CAK-4A) (not shown) must be used with SL300 chimney Combustible framing/header Non-combustible material Outside combustion air Hearth extension Protective metal hearth strip(s) Figure 2.1 Typical Fireplace System Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 7: Design And Installation Considerations

    4 2 -1/2 [ 1 08 0 ] 24 * [ 4 0 6 ] [ 6 1 0] Faceplate to sidewall 16 inches Figure 2.2 Fireplace Locations Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 8: Locating Fireplace & Chimney

    Location NOT recommended: • Not the highest point of the roof • Wind loading possible Location NOT recommended: • Too close to tree • Below adjacent structure Recommended: • Lower roof line • Insulated exterior chase • Avoid outside wall in cooler climates Windward Leeward Not recommended in basement due to high negative pressure concerns that effect draft Figure 2.3 Recommended Chimney Locations Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 9: Tools And Supplies Needed

    Chimney System - CAK4A Chimney air kit (included with fireplace, required with SL300 series chimney) - Attic Insulation Shield (included with fireplace) Chimney termination cap • Non-combustible finish material • Fans (included with fireplace) Optional components include: • LINTEL BAR-HHT - Lintel Bar Kit • Heat-Zone-WD-C Kit • OA-RD-6 - Outside Air Offset Adapter • Mesh-HHT-C - Firescreen Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 10: Framing And Clearances

    [ 2 48] [ 1 87] 37 [ 9 40] 40 [ 1 016] [ 2 5] [ 2 5] 42 [ 1 067] ► Figure 3.1 Appliance Dimensions Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 11: Clearances

    Electrical wires must be a minimum of 16 in. (406 mm) from top 0 in. to floor 1 in. (25 mm) to side of appliance Figure 3.2 Clearances to Combustible Materials Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 12: Construct The Chase

    DO NOT S D FN UHTX L U HGDL U V S D FHV ZL W KL Q V X O DWL R QRURWKHUP D WHUL D OV Figure 3.4. This will help reduce heat loss from the home around the fireplace. Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 13: Secure And Level The Fireplace

    The fireplace should be positioned so the face of the non- and wall. combustible material on the fireplace will be flush with the Figure 3.5 shows a typical framing (using 2 x 4 lumber) of face of the drywall on the walls. See Figure 3.6. the fireplace, assuming combustible materials are used. All required clearances to combustibles around the fireplace Level the fireplace and shim as necessary. Secure the fire- must be adhered to. See Figure 3.2. (No recess above fire- place (using the pallet mounting brackets located on either place.) side of the fireplace) to the sub floor. Figure 3.5 Framing the Fireplace Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 14: Installation Of Top Standoffs

    1 in. (25 mm) min. (51 mm) overlap Standoff Floor screwed to 2 in. (51 mm) Figure 3.10 Protect the Front of an Elevated Platform Figure 3.8 Screw Standoffs to Fireplace Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 15: Non-Combustible Facing Board (Provided)

    GHEUL V % O RFNDJ H V FRX O G FDX V H FRP E X V W L R QDL U V W DUY D WL R Q Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 16 Figure 3.14 Remove Cover Plate (Left Side) NOTE: An Outside Air Offset Adapter (OA-RD-6) is avail- able if needed. See Figure 3.15. Figure 3.18 Outside Air Installation with Cold Air Trap Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 17 • Install with short run and add a P-trap which will help prevent flow of cold air. • Secure flex duct with screws or wire ties. Figure 3.20 Outside Air Installation Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 18: Heat-Zone-Wd-C Kit (Optional)

    & 6 & & D Q D G L D Q ( O H F W U L F & R G H Possible Air Duct Runs / Locations Figure 3.24 Minimum Clearances to Combustibles Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 19 R I W K H ¿ U H S O D F H D V V H P E O \ package. Figure 3.26. Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 20 Adapter with sheet metal screws Install Grill with Louvers pointed down Adapter Mounting Plate 45° Elbow Mounting Bracket Starter Pipe can rotate 180° Cover Plate Figure 3.28 Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 21 $ ' - 8 6 7 $ % / ( 5 ( * , 6 7 ( 5 6 14-2 w/ground White White White Black Incoming Power Junction Box Removed (110V) Black Black Figure 3.33 Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 22: Electrical Wiring

    ‡ ' R Q R W F R Y H U R U E O R F N D Q \ F R R O L Q J D L U V O R W V Figure 4.3 Fan Wiring Diagram Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 23: Chimney And Termination Requirements

    ) D L O X U H WR GRV R P D \ FDX V H RY H UKHDWL Q J DQG¿ U H Figure 5.1 Chimney Requirements Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 24: Offsets/Returns

    84 1/8 2137 39 1/8 76 7/8 1953 22 3/4 91 7/8 2334 43 1/4 1099 84 1/8 2137 96 1/2 2451 45 1/8 1146 87 1/4 2216 25 7/8 103 1/2 2629 49 1/4 1251 94 1/2 2400 Proper assembly of air-cooled chimney parts result in an overlap at chimney joints of 1-1/4 in. (32 mm). Effective length is built into this chart. Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 25: Termination Requirements

    C. Termination Requirements • Install a cap approved and listed for this fireplace system. • Locate cap where it will not become plugged by snow or other materials. • Locate cap away from trees or other structures. • The bottom of the termination cap must be at least 3 ft (.91 m) above the roof AND at least 2 ft (.61 m) above any portion of roof within 10 ft (3.05 m) as shown in Figure 5.3. • The distance required between caps is shown in Figure 5.3. Figure 5.3 Multiple Chimney Locations Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 26: Chimney Installation

    DGMX V W P H QWL I V P R NL Q J RURY H UGUDIWRFFX U V Figure 6.1 Typical Chimney System - Guidelines for Chimney System Installation The SL300 series chimney (UL127 approved for use with this fireplace) is shipped with wrap around warning labels installed. These labels may be removed from the sections of chimney exposed above the roofline. Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 27: Assemble Chimney Sections

    QRW UHTX L U HG ZL W KD ' X U D3 O X V 6 \ V W HP • Install the chimney pipe first. • Hand bend the tabs in position before placing on the fireplace. Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 28: Secure Offset/Return

    When offsets and returns are joined to straight pipe sec- tions, they must be locked into position with screws (outer only). To prevent gravity from pulling the chimney sections apart, the returns and the chimney stabilizers have hanger straps for securing these parts to joists or rafters. See Fig- ure 6.5. * Use # 6 or # 8 sheet metal screw, or larger, no longer than 1/2 in. (13 mm). Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 29: Install Firestops

    H Q Y H O R S H R I W K H K R P H X V H ƒ ) V H D O D Q W Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 30: Install Attic Insulation Shield

    Check each section by pulling up slightly from the top to ensure proper engagement before installing the suc- ceeding sections. If they have been connected correct- ly, they will not disengage when tested. The chimney must be enclosed from the fireplace to the Figure 6.9 Install Attic Insulation Shield (firestop below ceiling) attic maintaining the 2 inch clearances to combustibles. Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 31: Roof Penetration

    • Locate the point where the chimney will exit the roof by plumbing down to the center of the chimney. Lay out, cut and frame a 14-1/2 in. (368 mm) square opening (measured on the horizontal) through the ceiling and roof structure. Consult local codes for framing details. Figure 6.12 Installing Part: 12966A, Configuration 1 Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 32: Install Chase/Chase Top

    T u rn-down Drip Edge Chase .018 ( 2 6 ga) min. Figure 6.14 Installing Part 12966A Configuration 3 Galvanized Chase Top Figure 6.15 Chase Top Construction Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 33: Install Termination Cap

    S D UWV H[ S R V H GWRWKHZHDWKHU Chase Chimney Pipe Figure 6.17 Installing a TR342-B Round Telescoping Termination Figure 6.16 Installing a TR344 Round Termination Cap Majestic • WarmMajic-II Installation Manual • 4188-901 • Rev F • 02/22...
  • Page 34 Place waterproof Flange caulk or sealer under Termination Cap each flange of the termination cap and on top of each screw to help prevent leaks. The last section of pipe must stop between 2 in. (51 mm) above the top of the chase and 4 3/4 in.