VWR avantor 76359-754 Instruction Manual

VWR avantor 76359-754 Instruction Manual

Real-time electrophoresis tank system

Advertisement

Quick Links

VWR® Real-Time Electrophoresis Tank System
North American Catalog Number: 76359-754
European Catalog Number: 700-1472
Instruction manual
This product is for research use only
Version 1
Issued: 08, 2021

Advertisement

Table of Contents
loading

Summary of Contents for VWR avantor 76359-754

  • Page 1 Instruction manual VWR® Real-Time Electrophoresis Tank System North American Catalog Number: 76359-754 European Catalog Number: 700-1472 This product is for research use only Version 1 Issued: 08, 2021...
  • Page 2 Legal Address of Manufacturer: Europe VWR International bv, Researchpark Haasrode 2020 Geldenaaksebaan 464 B-3001 Leuven +3216385011 be.vwr.com UK Importer: VWR International Ltd Hunter Boulevard, Magna Park Lutterworth, Leicestershire, LE17 4XN uk.vwr.com United States VWR International LLC 100 Matsonford Rd Radnor, PA 19087 +1 800-932-5000 www.vwr.com...
  • Page 3: Table Of Contents

    Keep this manual for future reference. Please check the list of included components in section 1.1, and if there are any parts missing, damaged, or incorrect, please contact your distributor or VWR’s Customer Service Department. vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 4: Included Component List

    The blue LED transilluminator and viewing filter are compatible with green fluorescent stains such as VWR’s EZ Vision Products, SYBR® Green, and other similar stains that fluoresce under 465nm blue light. Before use, please read this operating manual in its entirety.
  • Page 5: Diagrams Of Included Components

    1.2 Diagrams of Included Components Smart phone imaging enclosure with photo filter Safety Lid with Integral Viewing Filter and Power Leads Gel Running Tank Blue LED Transilluminator 12V Power Supply vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 6 Diagram of Included Components (Gel Casting Set Double Sided Comb (12/22 teeth) Short Gel Trays (10.5 x 6cm) Long Gel Tray (10.5 x 10cm) Gel Casting Divider Gel Casting Stand vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 7: Specifications

    DNA electrophoresis and that the output jacks on the power supply can accept the banana plugs on the power cords. The VWR 500V/400mA and VWR Mini Power Supply are recommended as compatible power supplies.
  • Page 8: Warnings

    Always use the system in an environment with low humidity and low dust , also keep away from water, direct sunlight / strong light, corrosive gas, high magnetic fields, heaters, fires and other heat sources. vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 9: Gel Preparation

    Note: when using the fine-toothed comb, the flat side of the well comb should be facing the direction of DNA travel. See figure below. vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 10 Carefully remove the gel tray with the gel from the stand and place it into the migration tank in the correct orientation. (DNA samples will migrate from the – to + electrode). vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 11: Gel Tank Set Up

    2 mm above the surface of the gel. Typically, 200ml of buffer is required. It is recommended to use TAE or TBE at a concentration of 0.5X. vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 12 If the buffer level is too low to contact the orange filter, remove the cover, and add more buffer to the tank. Slide the blue LED illuminator under the gel tank. vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 13: Electrophoresis

    It may be necessary to dim or turn off ambient lights for best viewing results. The LED illuminator has a built-in timer, so the light will automatically switch off after 5 minutes. vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 14: Imaging Using A Smart Phone

    Do not submerge the LED transilluminator in water. Clean gel casting stands, gel tray and combs with water or a neutral cleaner vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 15: Troubleshooting

    By doing so, you will help to conserve natural and environmental resources and you will ensure that your equipment is recycled in a manner that protects human health. Thank you vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...
  • Page 16: Technical Service And Warranty

    VWR warrants that this product will be free from defects in material and workmanship for a period of two (2) years from date of delivery. If a defect is present, VWR will, at its option and cost, repair, replace, or refund the purchase price of this product to the customer, provided it is returned during the warranty period.
  • Page 17: Local Vwr Offices In Europe And Asia Pacific

    Email: info.nl@vwr.com Freecall: 0800 702 00 07 Norway Tel.: +49 (0) 6151 3972 0 (international) VWR International AS Email: info.de@vwr.com Brynsalleen 4 0667 Oslo Tel.: +47 22 90 00 00 Email: info.no@vwr.com vwr.com | Instruction manual VWR® Real Time Electrophoresis Tank...