Caution For Ac Mains Lead - Panasonic SA-XR55E Service Manual

Av control receiver
Hide thumbs Also See for SA-XR55E:
Table of Contents

Advertisement

1.1.2. LEAKAGE CURRENT HOT CHECK (See Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a 1.5k
capacitors, between each exposed metallic part on the set and a
good earth ground such as a water pipe, as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more sensitivity, to
measure the potential across the resistor.
4. Check each exposed metallic part, and measure the voltage at
each point.
5. Reverse the AC plug in the AC outlet and repeat each of the above
measurements.
6. The potential at any point should not exceed 0.75 volts RMS. A
leakage current tester (Simpson Model 229 or equivalent) may be
used to make the hot checks, leakage current must not exceed 1/
2 milliamp. In case a measurement is outside of the limits
specified, there is a possibility of a shock hazard, and the
equipment should be repaired and rechecked before it is returned
to the customer.

2. Caution for AC Mains Lead

, 10 watts resistor, in parallel with a 0.15
F

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sa-xr55ebSa-xr55egSa-xr55

Table of Contents