Olympus SZ2-ILLC Instructions Manual

Coaxial illuminator
Hide thumbs Also See for SZ2-ILLC:

Advertisement

Quick Links

INSTRUCTIONS
SZ2-ILLC
Coaxial illuminator
This instruction manual is for the Olympus SZ2-ILLC Coaxial
Illuminator. To ensure the safety, obtain optimum performance
Optical Microscope Accessory
and to familiarize yourself fully with the use of this equipment, we
recommend that you study this manual thoroughly before operating
the system.
Retain this instruction manual in an easily accessible place near the
work desk for future reference.
A X 6 6 1 7

Advertisement

loading

Summary of Contents for Olympus SZ2-ILLC

  • Page 1 INSTRUCTIONS SZ2-ILLC Coaxial illuminator This instruction manual is for the Olympus SZ2-ILLC Coaxial Illuminator. To ensure the safety, obtain optimum performance Optical Microscope Accessory and to familiarize yourself fully with the use of this equipment, we recommend that you study this manual thoroughly before operating the system.
  • Page 3: Table Of Contents

    Contents Important ................................1 1 Nomenclature ............................6 2 Controls ................................7 3 Assembly ................................ 9 4 Coaxial reflected light observation ..................11 5 Troubleshooting guide ........................12...
  • Page 4: Important

    Important The coaxial illuminator enables coaxial reflected light observation when it is mounted at the bottom of an SZ2 series microscope. SAFETY PRECAUTIONS This unit can be used in combination with only the SZ2-CLS or LG-PS2 light guide illuminator. When using the LG-PS2, for safety, use only the lamp bulb designated in the following table. For details, refer to the “...
  • Page 5 Indicates that the main switch is OFF. Protective grounding, which can be used only by the Olympus service personnel for incorporating grounding in machines. Do not use this grounding for other purpose than the above.
  • Page 6 Getting Ready 1. The coaxial illuminator is a precision instrument. Handle it with care and avoid subjecting it to sudden or severe impact. 2. Do not use the coaxial illuminator where it is subjected to direct sunlight, high temperature and humidity, dust or vibrations.
  • Page 7 To clean the half mirror inside the coaxial illuminator, simply remove dust and dirt with a NOTE blower, etc. If the half mirror is still dirty after blowing, please contact Olympus. 2. Do not attempt to use organic solvents to clean the parts other than the glass components. To clean them, use a lint-free, soft cloth slightly moistened with a diluted neutral detergent.
  • Page 8 Caution If the coaxial illuminator is used in a manner not specified by this manual, the safety of the user may be imperiled. In addition, the equipment may also be damaged. Always use the equipment as outlined in this instruction manual. The following symbols are used to set off text in this instruction manual.
  • Page 9: Nomenclature

    SZ2-ILLC Nomenclature Dual Flexible Light Guide SZ2-CLGDF* or LG-DF Lightguide Illuminator SZ2-CLS* or LG-PS2 SZ2 series microscope body Coaxial Illuminator SZ2-ILLC Standard stand or Arms Used with Microscopes for Equipment Mounting · SZ2-ST · SZ2-STS · SZ2-STB1 * Name and detail specifications of this product...
  • Page 10: Controls

    Controls Coaxial Illuminator Dual Flexible Light Guide SZ2-ILLC SZ2-CLGDF* or LG-DF Mounting adapter Light guide input end Light guide mount port Clamping screw Mount Clamping screw Light guide output end Allen wrench * Name and detail specifications of this product...
  • Page 11 SZ2-ILLC Lightguide Illuminator Light Source SZ2-CLS* LG-PS2 Refer to the separate instruction manual. Refer to the separate instruction manual. Lightguide illuminator Light source AC adapter * Name and detail specifications of this product might differ in Europe, Middle East and Africa.
  • Page 12: Assembly

    SZ2-CLGDF* or LG-DF Mounting adapter Light Source LG-PS2 Lightguide Illuminator SZ2-CLS* Coaxial Illuminator SZ2-ILLC Standard Stand * Name and detail specifications of or Arms Used this product might differ in Europe, with Microscopes for Middle East and Africa. Equipment Mounting...
  • Page 13 Screw the mount adapter b fully into the bottom of the SZ2 series microscope body a by turning the mount adapter in the direction of the arrow. Loosen the clamping screw c of the SZ2-ILLC coaxial illuminator, fit the illuminator into the mount adapter b and tighten the clamping screw again.
  • Page 14: Coaxial Reflected Light Observation

    Coaxial reflected light observation The applicable observation magnifications are zoom magnifications of 2X or more when the 10X eyepieces are used. Place a specimen on the stage plate. Set the main switch of the illuminator to ON and adjust the brightness. Look through the eyepieces and rotate the focus adjustment knob to bring the specimen into focus.
  • Page 15: Troubleshooting Guide

    Under certain conditions, performance of the unit may be adversely affected by factors other than defects. If problems occur, please review the following list and take remedial action as needed. If you cannot solve the problem after checking the entire list, please contact Olympus. Problem...
  • Page 16 Please contact our "Service Center" through the following website for any inquiries or issues related to this product. EVIDENT CORPORATION 6666 Inatomi, Tatsuno-machi, Kamiina-gun, Nagano 399-0495, Japan (Life science solutions) (Life science solutions) Service Center Our Website https://www.olympus-lifescience.com/support/ https://www.olympus-lifescience.com service/ (Industrial solutions) (Industrial solutions) Service Center Our Website https://www.olympus-ims.com/service-and- https://www.olympus-ims.com...