SMARTIS
USER MANUAL
FW Version: 1.0.0
Release date: 27
th
January, 2021
Version : 210127 EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMARTIS and is the answer not in the manual?

Questions and answers

Summary of Contents for WORKSWELL SMARTIS

  • Page 1 WORKSWELL SMARTIS USER MANUAL FW Version: 1.0.0 Release date: 27 January, 2021 Version : 210127 EN...
  • Page 2: Table Of Contents

    7.1 Controlling SMARTIS ........
  • Page 3 9.1 System ..........9.1.1 Basic Settings .
  • Page 4 17. Maintanance 17.1 Cleaning the SMARTIS head and cables .......
  • Page 5: Introduction

    Workswell s.r.o. will, at its option, repair or replace any such defective product free of charge if, upon inspection, it proves to be defective in material or workmanship and provided that it is returned to Workswell within the said twelve‐month period.
  • Page 6: Help And Faq

    While looking for a solution of any technical problem we recommend following these steps: try to find an answer by searching this User Manual contact your dealer search Workswell s.r.o. website at https://workswell.cz/termokamera‐smartis/ log in and send an email to support.workswell.eu Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web...
  • Page 7: User Information

    3.3 Updates The primary aim of Workswell s.r.o. company is to supply their products in a way to meet the current needs of its users and at the same time to remove all the weaknesses that were found in their use as soon as possible.
  • Page 8: Warning And Cautions

    Plug the camera to its own power source. Do not plug the camera into the same power source as drone’s motors. ◦ ◦ Do not use the Workswell SMARTIS system in temperatures higher than +50 C (+122 F). High temperatures can cause damage to the camera.
  • Page 9: Revision History

    Added new support contact and version numbering. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 10: System Assembly

    Note: Exceeding the input power range may cause damage to the SMARTIS. 6.1.2 Digital Triggers You can trigger your SMARTIS with M12 8‐pin cable. Trigger level of each trigger is within range 8VDC ‐ 36VDC. You can see the trigger connector pinout in the Figure 6.2a.
  • Page 11: Digital Outputs

    6.1.3 Digital Outputs You can use 7 Digital Outputs of your SMARTIS with M12 8‐pin cable. Each Digital Output is set as an open collector circuit. You can see the Digital Outputs connector pinout in the Figure 6.3a and output’s schematics and example circuit in the Figure 6.4.
  • Page 12: Analog Outputs

    6. SYSTEM ASSEMBLY Figure 6.4: Output pin scheme. 6.1.4 Analog Outputs You can use 7 Analog Outputs of your SMARTIS with M12 8‐pin cable. Each Analog Output can be set as voltage or current loop: Voltage • ±12V • 0V ‐ 12V •...
  • Page 13: Mounting The System

    6. SYSTEM ASSEMBLY 6.2 Mounting the system Figure 6.6: SMARTIS mechanical drawings and dimensions. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary.
  • Page 14: General Usage Overview

    IP address 10.0.0.225. This IP address could be changed later. All the user needs for configuring and controlling the SMARTIS is computer or tablet with at least 10” screen with web browser. The built in web server should be running few seconds after the SMARTIS boots up.
  • Page 15: Admin And Operator Modes

    7.1.4 Admin and Operator Modes As with the two kind of users, there are two basic modes with different web pages on SMARTIS web server. If administrator logs in to web server, the ”Admin Mode” starts. If operator logs in, the ”Operator Mode” starts.
  • Page 16: Measurement Overview

    For further information, please refer to chapter 9.5. 7.3 Measurement overview When operator logs in, he should select the product. The SMARTIS will not evaluate any digital signal nor do any measurement until the operator starts the measurement session. 7.3.1 Measurement session When measurement session starts, the SMARTIS will perform an image calibration and will react to digital inputs and produce digital and analog outputs according to product settings.
  • Page 17: Login

    8. LOGIN Login If you power up the SMARTIS, log‐in screen appears. There are two types of log‐in screen, one if there is not any measurement in progress and one if there is. 8.1 No measurement in progress For logging in, follow these steps: 1.
  • Page 18: Measurement In Progress

    Figure 8.2: Main log‐in screen ‐ measurement in progress. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 19: Administrator Mode

    9. ADMINISTRATOR MODE Administrator Mode In Administrator mode, you can configure the SMARTIS for correct measurement. For correct settings, you have to go through all of the settings tabs. 9.1 System In this part, you can set: Basic Settings, Network Settings,...
  • Page 20: Network Settings

    For setting the new IP address or subnet mask, fill the numbers and press the Set Network button. After that, SMARTIS will reboot and start with the new IP address. You have to change the address in your web browser to the new one for connecting to the SMARTIS.
  • Page 21: Time And Date Settings

    1. Type in the new User name. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 22: Log Files Settings

    Figure 9.5: System ‐ Log Files settings. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 23: Products

    Figure 9.6: Products settings. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 24: Radiometry

    2. Start and Stop ‐ Two trigger signals ‐ one for starting and one for stopping the measurement. (a) Latch trigger. (b) Start‐Stop trigger. Figure 9.8: SMARTIS trigger options ‐ Latch or Start‐Stop triggers. For each trigger signal, you can select the steady‐state and ON‐state logical level to either: Headquarters...
  • Page 25: Frame Measurement And Evaluation

    Figure 9.9: SMARTIS trigger level options ‐ logical High or logical Low with the Latch trigger example. If you do not have any triggers available, you can control the SMARTIS via Ethernet commands. For this, check the Ethernet triggers checkbox. You can find more information about the Ethernet commands in the chapter 11.
  • Page 26: Start-Stop Measurement And Evaluation

    1. Two triggers ‐ start with one Start trigger and with one Stop trigger. 2. One trigger ‐ start with Latch trigger in logical high state and stop with Latch trigger in logical low state. When the measurement is active, SMARTIS takes and evaluates one frame repeatedly with Sample interval period.
  • Page 27: Non-Trigger Evaluation

    Figure 9.13: Non‐Trigger Evaluation example. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 28: Roi

    Figure 9.14: ROI shapes icons. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 29: Zoom

    Figure 9.16: Palette selection. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 30: Settings Panel

    Delete button. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 31 Figure 9.17: ROI settings panels. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 32: Table

    Specify the extreme value, that should be compared to the measurement value. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 33: Digital

    Administrator can copy the ROI settings to different ROI with the bottom table selection and ”Copy settings” button. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 34: Outputs

    Any temperature between the minimum and maximum will be represented as linear mapping of these values. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 35: Digital Outputs

    Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 36: Visualization

    Fail/Pass ‐ The measurement result. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 37: Finish

    9. ADMINISTRATOR MODE 9.9 Finish This is the last part of the SMARTIS settings. Administrator can choose one of the four possibilities: Save & New ‐ Save changes and continue with new product settings. Save & Log Off ‐ Save changes and log out.
  • Page 38: Operator Mode

    The selection of a product can take few seconds to load and apply. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 39 Figure 10.3: ROI Table. SMARTIS information and numeric indicators Some basic information about the SMARTIS and measurement can be found int the tab ”SMARTIS STATUS”. The selected numeric indicators (selected ROI and measurement information) can be found in the tab ”ROI STATUS”.
  • Page 40 Figure 10.6: Measurement graph. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 41: Measurement Types Differences

    Thus only the digital input Latch, Start and IC are enabled. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Reg. No.: 29048575 Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Prague, Czech Republic Real values may vary. VAT No.: CZ29048575 www.workswell.eu...
  • Page 42 Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 43: Work-Flow

    4. When the session is finished, stop the measurement by clicking on the Stop button. 5. Confirm your action by clicking the Ok button. 10.3 Measurement session When the measurement starts, the SMARTIS saves the state and continue the measurement until stopped by the operator or administrator. 10.3.1 Web server during measurement session...
  • Page 44: Ethernet

    11. ETHERNET Ethernet As an alternative to web server control we propose the TCP/IP communication. With simple TCP/IP text commands, user can control the SMARTIS device. Parameter Value Protocol TCP/IP IP address SMARTIS IP address Port number 2240 Table 11.1: TCP/IP control parameters 11.1 Communication Protocol...
  • Page 45 Request Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 46 • OK Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 47 User may want to download the data. The internal memory is also limited and once in a while may require to delete outdated data. The data are available through FTP server. 12.1 FTP Server The FTP server can be accessed on the SMARTIS IP address on the standard port 21. Parameter Value Protocol...
  • Page 48 The server was tested with the Filezilla software https://filezilla‐project.org/. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration. info@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 49 We will inform our customers about new software releases whenever available. 13.1 Firmware update Once you have obtained the update file, connect to the SMARTIS web server. The update file should have extension ”.wsm”. Log in as administrator and on tab ”System” on panel ”Basic Settings” select the update file.
  • Page 50 Workswell CorePlayer 14.1 General Description The Workswell SMARTIS system can capture radiometric images compatible with Workswell CorePlayer (supplied with Workswell SMARTIS system). Workswell CorePlayer offers the user many functions for editing and processing radiometric images. Workswell CorePlayer is available at http://www.workswell.eu/CorePlayer Figure 14.1: Workswell CorePlayer.
  • Page 51 ‐30 C to +60 Humidity 5‐95%, noncondensing Maximum irradiance 100W/cm If you use the product in conflict with these conditions, damage to the Workswell SMARTIS system can occur. Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration.
  • Page 52 The sensor starts warming‐up automatically when the user turns Workswell SMARTIS system on. The infrared camera is usually ready in less than 5 minutes. During the warm‐up process the accuracy of the measured temperature data is lower and various defects can appear in the thermal image.
  • Page 53 17. MAINTANANCE Maintanance 17.1 Cleaning the SMARTIS head and cables Liquids: Use one of these liquids: Warm water A weak detergent solution Equipment: A soft cloth Procedure: 1. Soak the cloth in the liquid. 2. Twist the cloth to remove excess liquid.
  • Page 54 When you can not connect to the SMARTIS via web‐browser, check that you have typed in correct IP address. In case that you do not know the IP address of the SMARTIS, you can press and hold the RESET button for more than 5 seconds to reset the SMARTIS IP address to default 10.0.0.225.
  • Page 55 18. TROUBLESHOOT 18.5 System Update Make sure that your SMARTIS version is up to date. You can find information about the current version on https://workswell.cz/termokamera‐smartis/ Headquarters Version 210127 EN, 27 Jan, 2021 E‐mail and Web Mobile: Libocka 653/51b All pictures are only for illustration.
  • Page 56 Meziricska 100 Mobile: +420 725 955 464 160 00, Prague6 756 61, Roznov p. R. E‐mail: adam.svestka@workswell.cz Czech Republic Czech Republic Company contact details Univerzitni 1 Mobile: +420 725 877 063 010 08, Zilina E‐mail: info@workswell.eu Slovak Republic Web: https://workswell.cz/termokamera‐smartis/...

Table of Contents