Hide thumbs Also See for SMARTIS:

Advertisement

Quick Links

WORKSWELL
SMARTIS
USER MANUAL
FW Version: 1.0.0
Release date: 13
th
July, 2017
Revision : 1.1 EN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SMARTIS and is the answer not in the manual?

Questions and answers

Summary of Contents for WORKSWELL SMARTIS

  • Page 1 WORKSWELL SMARTIS USER MANUAL FW Version: 1.0.0 Release date: 13 July, 2017 Revision : 1.1 EN...
  • Page 2: Table Of Contents

    7.1 Controlling SMARTIS ........
  • Page 3 9.1 System ..........9.1.1 Basic Se ngs .
  • Page 4 17. Maintanance 17.1 Cleaning the SMARTIS head and cables .......
  • Page 5: Introduc On

    Workswell s.r.o. will, at its op on, repair or replace any such defec ve product free of charge if, upon inspec on, it proves to be defec ve in material or workmanship and provided that it is returned to Workswell within the said twelve-month period.
  • Page 6: Help And Faq

    While looking for a solu on of any technical problem we recommend following these steps: try to find an answer by searching this User Manual contact your dealer search Workswell s.r.o. website at h ps://workswell.cz/termokamera-smar s/ send an email to support@workswell.eu Headquarters Revision 1.1 EN, 13...
  • Page 7: User Informa On

    3.3 Updates The primary aim of Workswell s.r.o. company is to supply their products in a way to meet the current needs of its users and at the same me to remove all the weaknesses that were found in their use as soon as possible.
  • Page 8: Warning And Cau Ons

    Plug the camera to its own power source. Do not plug the camera into the same power source as drone’s motors. ◦ ◦ Do not use the Workswell SMARTIS system in temperatures higher than +50 C (+122 F). High temperatures can cause damage to the camera.
  • Page 9: Revision History

    Ini al Release Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 10: System Assembly

    Note: Exceeding the input power range may cause damage to the SMARTIS. 6.1.2 Digital Triggers You can trigger your SMARTIS with M12 8-pin cable. Trigger level of each trigger is within range 8VDC - 36VDC. You can see the trigger connector pinout in the Figure 6.2.
  • Page 11: Digital Outputs

    6.1.3 Digital Outputs You can use 7 Digital Outputs of your SMARTIS with M12 8-pin cable. Each Digital Output is set as an open collector circuit. You can see the Digital Outputs connector pinout in the Figure 6.3a and output’s schema cs and example circuit in the Figure 6.3b.
  • Page 12: Moun Ng The System

    6. SYSTEM ASSEMBLY 6.2 Moun ng the system Figure 6.5 – SMARTIS mechanical drawings and dimensions. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg.
  • Page 13: General Usage Overview

    7.1 Controlling SMARTIS The SMARTIS is intended as all-in-one solu on featuring a thermal camera, control unit, I/O card, as well as a TPC/IP interface integrated within a single casing including an in-built web server allowing for communica on with a superior system, including any PLC with this interface.
  • Page 14: Admin And Operator Modes

    7.1.4 Admin and Operator Modes As with the two kind of users, there are two basic modes with different web pages on SMARTIS web server. If administrator logs in to web server, the ”Admin Mode” starts. If operator logs in, the ”Operator Mode” starts.
  • Page 15: Measurement Overview

    For further informa on, please refer to chapter 9.5. 7.3 Measurement overview When operator logs in, he should select the product. The SMARTIS will not evaluate any digital signal nor do any measurement un l the operator starts the measurement session.
  • Page 16: Login

    8. LOGIN Login If you power up the SMARTIS, log-in screen appears. There are two types of log-in screen, one if there is not any measurement in progress and one if there is. 8.1 No measurement in progress For logging in, follow these steps: 1.
  • Page 17: Measurement In Progress

    Figure 8.2 – Main log-in screen - measurement in progress. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 18: Administrator Mode

    9. ADMINISTRATOR MODE Administrator Mode In Administrator mode, you can configure the SMARTIS for correct measurement. For correct se ngs, you have to go through all of the se ngs tabs. 9.1 System In this part, you can set: Basic Se ngs,...
  • Page 19: Network Se Ngs

    For se ng the new IP address or subnet mask, fill the numbers and press the Set Network bu on. A er that, SMARTIS will reboot and start with the new IP address. You have to change the address in your web browser to the new one for connec ng to the SMARTIS.
  • Page 20: Time And Date Se Ngs

    1. Type in the new User name. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 21: Log Files Se Ngs

    Figure 9.5 – System - Log Files se ngs. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 22: Products

    Figure 9.6 – Products se ngs. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 23: Radiometry

    2. Start and Stop - Two trigger signals - one for star ng and one for stopping the measurement. (a) Latch trigger. (b) Start-Stop trigger. Figure 9.8 – SMARTIS trigger op ons - Latch or Start-Stop triggers. For each trigger signal, you can select the steady-state and ON-state logical level to either: Headquarters Revision 1.1 EN, 13...
  • Page 24: Frame Measurement And Evalua On

    (b) Logical Low. Figure 9.9 – SMARTIS trigger level op ons - logical High or logical Low with the Latch trigger example. If you do not have any triggers available, you can control the SMARTIS via Ethernet commands. For this, check the Ethernet triggers checkbox.
  • Page 25: Start-Stop Measurement And Evalua On

    1. Two triggers - start with one Start trigger and with one Stop trigger. 2. One trigger - start with Latch trigger in logical high state and stop with Latch trigger in logical low state. When the measurement is ac ve, SMARTIS takes and evaluates one frame repeatedly with Sample interval pe- riod.
  • Page 26: Non-Trigger Evalua On

    Figure 9.13 – Non-Trigger Evalua on example. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 27: Roi

    Figure 9.14 – ROI shapes icons. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 28: Zoom

    Figure 9.16 – Pale e selec on. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 29: Se Ngs Panel

    Delete bu on. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 30 Figure 9.17 – ROI se ngs panels. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 31: Table

    Specify the extreme value, that should be compared to the measurement value. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 32: Digital

    Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 33: Outputs

    Any temperature between the minimum and maximum will be represented as linear mapping of these values. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 34: Digital Outputs

    Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 35: Visualiza On

    Fail/Pass - The measurement result. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 36: Finish

    9. ADMINISTRATOR MODE 9.9 Finish This is the last part of the SMARTIS se ngs. Administrator can choose one of the four possibili es: Save & New - Save changes and con nue with new product se ngs. Save & Log Off - Save changes and log out.
  • Page 37: Operator Mode

    The selec on of a product can take few seconds to load and apply. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 38 SMARTIS informa on and numeric indicators Some basic informa on about the SMARTIS and measurement can be found int the tab ”SMARTIS STATUS”. The selected numeric indicators (selected ROI and measurement informa on) can be found in the tab ”ROI STA- TUS”.
  • Page 39 Figure 10.6 – Measurement graph. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 40: Measurement Types Differences

    Thus only the digital input Latch, Start and IC are enabled. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 41 Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 42: Work-Flow

    5. Confirm your ac on by clicking the Ok bu on. 10.3 Measurement session When the measurement starts, the SMARTIS saves the state and con nue the measurement un l stopped by the operator or administrator. 10.3.1 Web server during measurement session...
  • Page 43: Ethernet

    11. ETHERNET Ethernet As an alterna ve to web server control we propose the TCP/IP communica on. With simple TCP/IP text com- mands, user can control the SMARTIS device. Parameter Value Protocol TCP/IP IP address SMARTIS IP address Port number 2240 Table 11.1 –...
  • Page 44 Request Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 45 • OK Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 46 Administrator and users can copy files from FTP server, but only administrator can delete file on the FTP server. 12.1.1 Restric ons and warnings The FTP server is available even during measurements, when SMARTIS can be doing cri cal opera ons. Thus, following restric ons should be observe with cau on: Do not delete current log folders during measurement session.
  • Page 47 The server was tested with the Filezilla so ware h ps://filezilla-project.org/. Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on. support@workswell.eu +420 725 877 063 Reg. No.: 29048575 Prague, Czech Republic Real values may vary. www.workswell.eu VAT No.: CZ29048575...
  • Page 48 We will inform our customers about new so ware releases whenever available. 13.1 Firmware update Once you have obtained the update file, connect to the SMARTIS web server. The update file should have ex- tension ”.wsm”. Log in as administrator and on tab ”System” on panel ”Basic Se ngs” select the update file.
  • Page 49 14.1 General Descrip on The Workswell SMARTIS system can capture radiometric images compa ble with Workswell CorePlayer (sup- plied with Workswell SMARTIS system). Workswell CorePlayer offers the user many func ons for edi ng and processing radiometric images. Workswell CorePlayer is available at h p://www.workswell.eu/CorePlayer Figure 14.1 –...
  • Page 50 15. ENVIRONMENT CONDITIONS Environment Condi ons 15.1 Environment Condi ons You should follow these storage and opera ng condi ons for proper func on of the Workswell SMARTIS system: ◦ ◦ Opera on temperature range from -15 C to +50 ◦...
  • Page 51 The sensor starts warming-up automa cally when the user turns Workswell SMARTIS system on. The infrared camera is usually ready in less than 5 minutes. During the warm-up process the accuracy of the measured temperature data is lower and various defects can appear in the thermal image.
  • Page 52 17. MAINTANANCE Maintanance 17.1 Cleaning the SMARTIS head and cables Liquids: Use one of these liquids: Warm water A weak detergent solu on Equipment: A so cloth Procedure: 1. Soak the cloth in the liquid. 2. Twist the cloth to remove excess liquid.
  • Page 53 When you can not connect to the SMARTIS via web-browser, check that you have typed in correct IP address. In case that you do not know the IP address of the SMARTIS, you can press and hold the RESET bu on for more than 5 seconds to reset the SMARTIS IP address to default 10.0.0.225.
  • Page 54 18. TROUBLESHOOT 18.5 System Update Make sure that your SMARTIS version is up to date. You can find informa on about the current version on h ps://workswell.cz/termokamera-smar s/ Headquarters Revision 1.1 EN, 13 Jul, 2017 E-mail and Web Mobile: Libocka 653/51b All pictures are only for illustra on.
  • Page 55 Mobile: +420 725 955 464 160 00, Prague6 756 61, Roznov p. R. E-mail: adam.svestka@workswell.cz Czech Republic Czech Republic Company contact details Univerzitni 1 Mobile: +420 725 877 063 010 08, Zilina E-mail: info@workswell.eu Slovak Republic Web: h ps://workswell.cz/termokamera-smar s/...

Table of Contents