8. Maintenance

Scanning glass and rollers

Clean the scanning glass and rollers frequently to ensure that your
transmitted images and copies are of the highest quality.
Open the operation panel (grasp the panel release and pull up), and wipe the
scanning glass, rollers and white backplate with a soft cloth.
Make sure that all dirt and stains (such as correcting fluid) are removed, as
dirts and stains will cause vertical lines on transmitted images and copies.
1
Squeeze the panel release and open
the operation panel.
2
Wipe the scanning glass (under the white roller) and rollers with a
cotton swab.
Make sure that all dirt and stains (such
as correcting fluid) are removed. Dirt
and stains will cause vertical lines on
transmitted images and copies.
If the scanning glass is difficult to clean
If you find it difficult to remove dirt from the scanning glass, you can try moistening
the swab with isopropyl alcohol or denatured alcohol. Take care that no alcohol
gets on the rollers.
3
Close the operation panel.
90
White
backplate
Document rollers
Scanning glass