Section 3
Installation Details

3.1 Gas Requirements

The fire feature should be placed on a flat and level surface. It will arrive with the burner and burner
plate set inside the unit. Burner hardware has been installed at the factory but will need to be checked
for proper tightness after transportation. Refer to the corresponding section below for set-up on your
unit. All units must have clearance to combustible surface of 4ft on all sides & 6ft from the top.
3.1.1 Propane Gas
Gas Pressure: 11 inches water column
Gas Input Flow: 65,000 BTUs/HR
Make sure the foundation is flat and level prior to placement. Units that use liquid propane will come
with a burner, orifice, flex hose and regulator that will attach to the propane tank. This gas hose will
need to go from the tank to the burner. The hose should connect from the key valve within the unit,
through a vent underneath and to the propane tank. Make sure all fittings are tightened properly with a
wrench, do not hand tighten! An additional flex hose will be attached to the other end of the key valve
to the flare fitting at the bottom of the burner. The arrow on the key valve should be pointing the
direction of the gas flow (towards the burner plate on your fire feature).
Fire features do not include propane cylinder; you will need to provide one. The liquid propane supply
cylinder must be constructed and marked in accordance with the specifications for propane gas
cylinders as required by the U.S. Department of Transportation (DOT).

3.2 Internal View of Components