Storage And Re-Packing The Unit; Troubleshooting Guide - Nice NICE1 User Manual

Hide thumbs Also See for NICE1:
Table of Contents

Advertisement

8.
Press the DRAIN button to continue with draining
the unit or press CANCEL to go back to the beginning.
9.
The Cooling Unit will display confirmation that
the unit has been fully drained.
11

STORAGE AND RE-PACKING THE UNIT

When therapy is complete, and it is time to return or store NICE1.
Turn the unit OFF and unplug from the electrical source.
Remove all therapy wraps.
Disconnect all fittings from the rear and front panel of the unit.
Follow the "Draining Fluid from the Cooling Unit" instructions in
Section 10.
Leave reservoir cap off to allow the unit to dry completely.
replace cap upon completion.
Collect the following items together:
o Cooling Unit
o Power Supply
o Power Cord
o Hose
o Wrap
o Padded Carrying Case
o Optional Shipping Box
NICE RECOVERY SYSTEMS
20
12
3-100176, REV E
Store the above items in the original box or in the
travel case you received.
Store indoors in an ambient environment of the following ranges:
-25°C to +5°C, and +5°C to 35°C at RH up to 90% non-condensing,
and >+35°C to 70°C at water vapor pressure 50hPa.
Failure to properly store the unit and wraps may result in damage to the unit,
hoses and/or wraps.

TROUBLESHOOTING GUIDE

NICE1 has many internal software safeguards to help protect the users and the
unit from unsafe operation. In this section you will find a list of system warnings
and errors that may occur if a potentially unsafe situation arises while using
NICE1. Neither the unit nor the wraps are intended for field repair. Do not
attempt to service the unit in any way. Troubleshooting steps are included.
Errors indicate the system has detected an issue and has stopped to protect
the user. The error state must be corrected before any therapy can be restarted.
An audible notification is also initiated as a beeping noise.
System errors indicate that an error has been detected and all current therapies
are halted to protect the user. System errors typically require service to the
Cooling Unit to correct the problem. If you encounter a system error, notate
code indicated on the display and contact the supplier or Durable Medical
Equipment (DME) provider. If assistance is not available, please contact NICE
Recovery technical assistance.
Below is a list of common user-related warnings and errors that may occur
during therapy operation of the unit.
3-100176, REV E
NICERECOVERY.COM
21