  • Page 1 NICE1 Cold + Compression Therapy System...
  • Page 3 System. The NICE1 uses advanced technology to greatly improve the convenience and efficacy of cold + compression therapy. This manual has all the information you need to properly and effectively operate the NICE1. Consult a healthcare professional before using NICE1.
  • Page 4 QUICK START GUIDE Consult a healthcare professional before using NICE1. • Connect the power cord to the external power supply. • Plug the circular connector into the back of the Cooling Unit. You will hear a click when properly connected.
  • Page 5 Select desired COLD LEVEL and press NEXT. device. The touch screen will illuminate and Cold Settings are as follows: display the “Nice” logo. Push “NEXT” . Review Level 1 = 58F (14.4C) Level 2 = 54F (12.4C) the checklist on the touch screen. Confirm and Level 3 = 50F (10C) press “NEXT”.
  • Page 6 COOLING State-of-the-art technology delivers therapeutic cooling without ice. The most convenient way to apply cold therapy. COMPRESSION Programmable intermittent and constant compression greatly improves the effectiveness of cold therapy and promotes healing. RECOVERY By combining the therapeutic benefits of cooling and compression in a single easy- to-use device, recovery times are greatly improved.
  • Page 7: Table Of Contents

    Introduction NICE1 description Indications for use Contraindications, cautions, and warnings Unpacking NICE1 Environmental conditions How to set up your NICE1 for therapy Operating instructions Maintenance and cleaning Draining the water from the unit Storage and re-packing the unit Troubleshooting guide...
  • Page 8: Introduction

    CAUTION: Federal law restricts this device to sale by or on the order of a physician. NICE1 DESCRIPTION NICE1 is a cold and compression therapy device used to aid recovery and reduce pain associated with soft tissue injuries. The device works by circulating cooled water and air through a therapy wrap that is placed on the body part.
  • Page 9 2.3 MEDICAL SYSTEM SPECIFICATIONS • Specified Medical Grade Power Supply. The following Power Supply is specified for use with the NICE1 unit: o Class II Power Supply: DC output rated 15Vdc 12A NOTE: A detachable type power supply cord (rated 125V 10A) is provided with each power supply, suitable for use in the USA and Canada.
  • Page 10: Indications For Use

    Raynaud’s disease or cold hypersensitivity (cold urticarial). 4.3 PRECAUTIONS Basic safety precautions should always be followed when using NICE1 to reduce the risk of fire, electric shock, and personal injury. Please read the entire User Manual carefully before operating the unit.
  • Page 11 • Use of this device may also cause frostbite or tissue damage if used incorrectly. • The unattended use of NICE1 by children or incapacitated persons may be dangerous. • If unusual swelling, skin discoloration or discomfort occurs, immediately discontinue use of NICE1 and consult a healthcare professional.
  • Page 12: Unpacking Nice1

    All of these items are needed for safe system operation. If any of these items are missing, please contact the clinic or hospital that prescribed the unit, or your Durable Medical Equipment (DME) supplier or provider or Nice Recovery Systems.
  • Page 13: Environmental Conditions

    ENVIRONMENTAL CONDITIONS NICE1 is intended for indoor use only. Do not operate NICE1 in or near a wet environment. NICE1 is not to be used in a confined space. Adequate airflow is necessary for the proper functioning of the device. It is recommended that the device have at least 12 inches of clearance in the front and back for adequate airflow.
  • Page 14 Connect the hose to the Cooling Unit. You will hear a click when properly connected. • Place the wrap on the appropriate body part. Secure with hook and loop. • Connect the hose to the wrap. You will hear a click when properly connected. NICE RECOVERY SYSTEMS...
  • Page 15: Operating Instructions

    The patient MUST be familiar with all warnings and cautions listed in Section 2 before attempting to operate the unit. NICE1 is capable of performing therapies for the following: • Cold Therapy •...
  • Page 16 Select desired COMPRESSION LEVEL and COMPRESSION TYPE and press NEXT. STEP 5 Choose a MANUAL time setting of 5 – 40 minutes for a single therapy session OR choose a PRESET PROGRAM for multiple sessions and press NEXT. NICE RECOVERY SYSTEMS...
  • Page 17 STEP 6 Review and confirm your settings by pressing START or press BACK to change the settings. STEP 7 During your therapy session you can change the cold or compression settings simply by pressing 1 – 5 or HIGH, MED or LOW. STEP 8 When the therapy session is complete is complete turn the unit OFF.
  • Page 18: Maintenance And Cleaning

    Turn the Cooling Unit OFF. Disconnect the therapy wrap from the hose. Connect the Drain Fitting to the end of the hose. Note: Drain completely before traveling on an airplane or shipping. NICE RECOVERY SYSTEMS...
  • Page 19 Place the tapered end of the drain fitting in bottle or other receptacle, capable of holding a minimum of 350mL. Turn the Cooling Unit ON. Press the DRAIN COOLANT button. Review the checklist and press NEXT. NICERECOVERY.COM...
  • Page 20: Storage And Re-Packing The Unit

    The Cooling Unit will display confirmation that the unit has been fully drained. STORAGE AND RE-PACKING THE UNIT When therapy is complete and it is time to return or store NICE1. • Turn the unit OFF and unplug from the electrical source.
  • Page 21: Troubleshooting Guide

    NICE1. Neither the unit nor the wraps are intended for field repair. Do not attempt to service the unit in any way. Troubleshooting steps are included.
  • Page 22 Restart therapy. If problem persists, contact customer service. Fan Error Turn off device, remove wrap and contact customer service. Error Message: 109 Cooling System Error Turn off device, remove wrap and contact customer service. Error Message: 110 NICE RECOVERY SYSTEMS...
  • Page 23: Service And Customer Support

    Over-Temp Error Error Message: 212 SERVICE AND CUSTOMER SUPPORT Nice Recovery Systems, LLC is committed to servicing our NICE1 both during and after sale to the customer. If you have any questions concerning the operation of your Nice Recovery Systems, please...
  • Page 24: Warranty And Disclaimer Information

    Nice Recovery products, that any Nice Recovery Systems will be free from defects in workmanship and material under normal use for one year (1) after the date of purchase. Nice Recovery warrants to the immediate purchaser from Nice Recovery, or an immediate...
  • Page 25: Electromagnetic Compatibility

    GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC EMISSIONS The NICE1 is intended for use in the electromagnetic environment specified below. The customer or the user of the NICE1 should assure that it is used in such an environment. EMISSIONS TEST COMPLIANCE ELECTROMAGNETIC ENVIRONMENT –...
  • Page 26 GUIDANCE AND MANUFACTURER’S DECLARATION – ELECTROMAGNETIC IMMUNITY The NICE1 is intended for use in the electromagnetic environment specified below. The customer or the user of the NICE1 should assure that it is used in such an environment. IMMUNITY TEST IEC 60601 TEST LEVEL...
  • Page 27 PORTABLE AND MOBILE RF COMMUNICATIONS EQUIPMENT AND THE NICE1 The NICE1 is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the NICE1 can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the NICE1 as recommended below, according to the maximum output power of the communications equipment.