Sanyo VCC-MD300 Technical Manual

Ntsc/pal color camera module

Advertisement

Quick Links

Technical Manual
Color Camera Module
Model No.
VCC-MD500/MD500P
VCC-MD600/MD600P
VCC-MD700/MD700P
VCC-MD800/MD800P
Please note that specifications and unit exterior design are subject to change without notifications.
(Ver 1.03)
(Ver 1.04)
• NTSC Model
VCC-MD800
VCC-MD700
VCC-MD600
VCC-MD500
VCC-MD400
VCC-MD300
• PAL Model
VCC-MD800P
VCC-MD700P
VCC-MD600P
VCC-MD500P
VCC-MD400P
VCC-MD300P
(×36, Day/Night type)
(×36, Color type)
(×30, Day/Night type)
(×30, Color type)
(×22, Day/Night type)
(×22, Color type)
(×36, Day/Night type)
(×36, Color type)
(×30, Day/Night type)
(×30, Color type)
(×22, Day/Night type)
(×22, Color type)
VCC-MD400/MD400P
VCC-MD300/MD300P

Advertisement

Table of Contents
loading

Summary of Contents for Sanyo VCC-MD300

  • Page 1 Technical Manual Color Camera Module Model No. • NTSC Model VCC-MD800 VCC-MD700 VCC-MD600 VCC-MD500 VCC-MD400 VCC-MD300 • PAL Model VCC-MD800P VCC-MD700P VCC-MD600P VCC-MD500P VCC-MD400P VCC-MD300P VCC-MD500/MD500P VCC-MD600/MD600P VCC-MD700/MD700P VCC-MD800/MD800P Please note that specifications and unit exterior design are subject to change without notifications.
  • Page 2: Table Of Contents

    Contents Parts Names and Dimensions ... 2 Connection ... 4 [1] Connection of the Interface Board and Camera Unit ... 4 [2] Interface Board Specifications ... 4 Input-Output Terminal Descriptions ... 5 [1] Input-Output Terminal Layout and Specifications ... 5 [2] FFC Compliance ...
  • Page 3: Parts Names And Dimensions

    Parts Names and Dimensions ■ VCC-MD800/700/600/500 Series Lens ■ Dimensions Note: The numbers within the brackets refer to the dimensions of the VCC-MD700 and MD800 models. CN204 terminal 3-M2 SCREW 25.1 (2.2) 3.53 3-M2 SCREW 25.1 − 2 − 4-M2 SCREW TAP 4-M2 SCREW TAP...
  • Page 4 Parts Names and Dimensions ■ VCC-MD400/MD300 Series Lens ■ Dimensions Note: The numbers within the brackets refer to the dimensions of the VCC-MD400 model. CN204 terminal: MD300 CN301 terminal: MD400 4-M2 12.5 4-M2 − 3 −...
  • Page 5: Connection

    Connection [1] Connection of the Interface Board and Camera Unit Connect the camera unit and the interface board using the FFC (flexible flat cable). Connect the various terminals of the interface board using the necessary cables. V PULSE [2] Interface Board Specifications Connector Terminal Name CN001...
  • Page 6: Input-Output Terminal Descriptions

    Input-Output Terminal Descriptions [1] Input-Output Terminal Layout and Specifications Power Supply: DC 6-12V CAMERA DC N (+6 – 12V) GND (DC) VIDEO GND (VIDEO) LINE IN GND (LINE IN) [2] FFC Compliance FCI SFW9R-1STE1LF (Lead Free Product) ⁃ Core Number Pitch Between Conductors Length of Recommended Insulation Thickness of Terminal...
  • Page 7: Communications Protocol

    Communications Protocol [1] Communications Format The communication unit is a 4 (min)-24 (max) byte packet. ・Communications Speed: 2400, 4800, 9600, 19200, 38400 9600 bps (DEFAULT MD800 – 500) * MD400 and MD300 cannot connect at 38400bps. DEFAULT is 19200bps. ・Data Length: 8 bit ・Start Bit: 1 bit ・Stop Bit:...
  • Page 8: Communications Flow

    Communications Protocol [2] Communications Flow Note: ◦ S tart the transmission of the next data after confirming the response command. ◦ T he maximum transmission interval of the various byte data is 500 [msec]. If this is exceeded, a communication error is detected in the camera unit, the receiving data is deleted, and data from the header is waiting to be received again.
  • Page 9: Command List For Md800-500

    Communications Protocol [3] Command List for MD800-500 Message System All Initial A0 01 0A CS FF All Menu Initial A0 01 0B CS FF Lens Initial A0 01 0C CS FF Reset A0 01 0D CS FF Menu Initial A0 01 0E CS FF Pixel defect compensation A0 01 12 00 06 04 04 0C CS FF...
  • Page 10 Communications Protocol Message Backlight BLC OFF A0 06 00 CS FF Multi BLC ON A0 06 01 CS FF Multi BLC Weight - A0 06 04 00 CS FF Multi BLC Weight + A0 06 04 01 CS FF Multi BLC Weight Preset A0 06 05 CS FF Multi BLC Weight Direct A0 06 06 0p CS FF...
  • Page 11 Communications Protocol Message Sync Sync INT A0 09 00 CS FF Sync L-L A0 09 01 CS FF L-L Phase + A0 09 0B CS FF L-L Phase - A0 09 0C CS FF L-L Phase Preset A0 09 0F CS FF L-L Phase Direct A0 09 13 0p 0q 0r COLOR MAX Gain...
  • Page 12 Communications Protocol Message Zoom Ratio A0 14 00 0p CS FF Zoom Ratio Position A0 14 01 p Direction A0 14 02 0p CS FF Direction Position A0 14 03 0p 0q CS FF Set North A0 14 04 0p CS FF Rom Version Display A0 14 10 0p CS FF Camera...
  • Page 13: Command List (Query) For Md800-500

    Communications Protocol Model: VCC-MD800/700/600/500 − 12 −...
  • Page 14 Communications Protocol Model: VCC-MD800/700/600/500 − 13 −...
  • Page 15 Communications Protocol Model: VCC-MD800/700/600/500 − 14 −...
  • Page 16: Command List For Md400 And 300

    Speed 1-4 during Far and Near commands (1: Slow-4: Fast (Initial value: 2)) CS FF pqr: Direct Position (VCC-MD400 0:Far 3524:Near VCC-MD300 0:Far 4008:Near) p: Subject distance limit during auto focus and manual focus (0: 10 cm, 1: 30cm, 2: 50 cm, 3: 1 m [Initial value], 4: 3 m, 5: 5 m)
  • Page 17 Communications Protocol Message Backlight BLC OFF A0 06 00 CS FF Multi BLC ON A0 06 01 CS FF Multi BLC Weight - A0 06 04 00 CS FF Multi BLC Weight + A0 06 04 01 CS FF Multi BLC Weight Preset A0 06 05 CS FF Multi BLC Weight Direct A0 06 06 0p CS FF...
  • Page 18 Communications Protocol Message Camera A0 15 00 CS FF A0 15 01 CS FF ID SET (ASCII code) A0 15 09 p   ID X-Position + A0 15 0B CS FF ID X-Position - A0 15 0C CS FF ID Y-Position + A0 15 10 CS FF ID Y-Position -...
  • Page 19 Communications Protocol Message DAY/ D/N COLOR *1 A0 28 00 CS FF NIGHT D/N BLACK/WHITE *1 A0 28 01 CS FF D/N AUTO *1 A0 28 02 CS FF D/N BURST OFF *1 A0 28 03 CS FF D/N BURST ON *1 A0 28 04 CS FF D/N LEVEL *1 A0 28 05 0p CS FF...
  • Page 20: Command List (Query) For Md400 And 300

    Communications Protocol Model: VCC-MD400/300 − 19 −...
  • Page 21: Notes

    Communications Protocol [7] Notes Note 1 Area Settings Divide the screen into 48 areas (6 vertical and 8 horizontal) and set an area to “1” to configure the mask and “0” to not configure the mask. On a row, bits 1 to 4 from the left are on the upper level and bits 5 to 8 are on the lower level.
  • Page 22 Communications Protocol Model: VCC-MD800/700/600/500/400/300 − 21 −...
  • Page 23 Communications Protocol Model: VCC-MD800/700/600/500/400/300 − 22 −...
  • Page 24 Communications Protocol Note 3 Exclusive processing Setting to auto iris mode, when SENSE UP is set ⁃ When unable to set ・ C annot be set when the motion sensor is set to ・Cannot be set when auto pursuit is set to ON. Auto switch setting ・Sets AGC to ON.
  • Page 25 Communications Protocol Model: VCC-MD800/700/600/500/400/300 − 24 −...
  • Page 26 Communications Protocol Note 4 Orientation / angle display The display angle is changed using Pan/Tilt Degree commands. The Set North command sets the current position to N and the pan degree to 0. Pan angle versus orientation is as follows. 337.6-22.5 22.6-67.5 67.6-112.5...
  • Page 27 Communications Protocol *MD400(P), MD300(P) responds error(FC) with commands above. *Commands below can be used to detect MD400(P) and MD300(P) Status Command: 80 46 01 CS FF Status Response Command: C0 46 01 p q r s t u CS FF   ↑...
  • Page 28: Function Descriptions

    Function Descriptions [1] Zoom Control Zoom Position Control The zoom can be operated using Tele/Wide or moving the zoom to a specific position. Direct ⁃ The Direct command can move the zoom lens to the specified zoom lens position. The relation between the zoom lens position and magnification is as follows. Digital Zoom Tele Limiter command needs to be sent before the Direct command when moving to digital zoom field.
  • Page 29: Focus Control

    Function Descriptions Optical Zoom Limit Settings The optical zoom magnification can be limited using the Optical Zoom Tele Limiter command. The digital zoom cannot be used if the limit is set to the Tele side. Digital Zoom A maximum of 16x digital zoom can be set with the Digital Zoom Tele Limiter command.
  • Page 30: Iris Control

    Function Descriptions [4] IRIS Control Auto Iris ⁃ The lens aperture is automatically controlled to correct the brightness of the average luminance value of the image. Manual Iris ⁃ This fixes the lens aperture. The aperture position can be set to a range of 17 levels (1: close - 7: open) using the Manual IRIS Stop command.
  • Page 31: Backlight Compensation

    Function Descriptions Auto Iris (SENSE UP OFF) Diagram 1 AGC Gain Lens open Aperture close Slow Electronic Shutter (Optional) Fast Manual Iris (EI OFF) Diagram 3 AGC Gain open Lens Aperture (Optional) close Slow Electronic Shutter (Optional) Fast [7] Backlight Compensation Multi-Area Light Measuring ⁃...
  • Page 32: Aperture

    Function Descriptions [8] Aperture Emphasizes contours and increases the vividness of the entire image. [9] Motion Detection The screen is divided into 48 areas (8 x 6) and movement is detected from changes in brightness of representative points within each area. The detection status can be confirmed by enquiring using the Status command.
  • Page 33: Privacy Mask Settings

    Function Descriptions [11] Privacy Mask Settings Display Area: NTSC (PAL) 0x26 (0x2A) 0x6C (0x6E) 0x9E (0x9F) 0xE4 (0xE3) 0x07 (0x0A) 0x35 (0x41) 0x54 (0x64) 0x82 (0x9B) * Area initially displayed using the Area Mask ON command. Notes: ・ M inimum unit for the mask width is 4 pixels horizontally and minimum unit for the mask height is 2 lines vertically.
  • Page 34 Function Descriptions Setting the Mask Position (Area Mask Position Set) x-Coordinate x-Coordinate Start Position End Position y-Coordinate Start Position y-Coordinate End Position If the coordinates increase by 1, the position moves by 4 horizontal pixels and 2 vertical lines. The upper left and lower right horizontal and vertical coordinates (1 byte each) are each divided into upper and lower 4 bits.
  • Page 35: Stabilizer

    Function Descriptions [12] Stabilizer (Only VCC-MD700/800 series) When this function is set to ON, the digital zoom magnifies the screen. When vibrations are detected, the vibrations are stabilized by changing the position of the screen captured by the zoom. Stabilizer level and digital zoom magnification When changing the stabilizer level, the magnification of the applied digital zoom is changed.
  • Page 36: Auto Pursuit Function

    Function Descriptions [13] Auto Pursuit Function Detects movement on the screen and calculates the level of movement. Subject pursued: Walking person Area:1x Zoom, object = a person at 8m distance Speed: 4km/hour - 6km/hour Motion detection: Uses the motion detection function Detection area: 16 x 12, total of 192 blocks Detection conditions: Continuous movement detection area...
  • Page 37: Application Software

    Application Software [1] Camera Control Command Transmission 1-1 Control using the Command Button The camera unit can be controlled by clicking the various command buttons. The command data transmitted and received by the PC can be confirmed using the “SENDING DATA” and “RECEIVING DATA”...
  • Page 38: Spectral Sensitivity Characteristics

    Spectral Sensitivity Characteristics Wave Length [nm] Wave Length [nm] Wave Length [nm] − 37 − MD800(P) (Color Mode) MD700(P) MD600(P) (Color Mode) MD500(P) MD400(P) (Color Mode) MD800(P) (Night Mode) MD600(P) (Night Mode) MD400(P) (Night Mode) 1000 MD300(P)
  • Page 39: Specifications

    – – ATW/Manual/Push-Look On (adjust gain)/Off On/Off 9–12V DC 450mA/12V DC 50(W) x 60(H) x 89.5(D) mm Approx. 230g VCC-MD300 Color 22x optical zoom f=4–88 mm, F1.6–3.8 47.3° to 2.2° 36.3° to 1.4° 57.4° to 2.5° 2.0lx (F1.6, gain: max.) –...
  • Page 40 Specifications • PAL system Model VCC-MD800P Day/night Image size Effective picture elements 36x optical zoom Lens f=3.4–122.4 mm, F1.6–4.5 Horizontal View angle Vertical Diagonal Digital zoom Resolution 1.0lx (F1.6, color, gain: max.) 0.05lx Minimum illumination (F1.6, B/W, gain: max.) 0.0015lx (F1.6, B/W, 32x) S/N ratio Synchronizing system...
  • Page 41: Change History

    Change history 2006.12.20: the issue of ver 1.00 2007.02.15: the issue of ver 1.01 • Changes the DEFAULT communication speed (BAUDRATE) of the MD800 – 500 to 9600 bps. • Newly added commands. Cover Offset OFF/ON Cover Offset Level Auto Focus Mode during pan/tilt ATW Mask Display Center BLC Area Display BLC Mask Display...
  • Page 42 Change history Shifting to digital zoom area Pan/Tilt Degree commands Center BLC Area Direct commands Privacy Mask related commands − 41 −...

Table of Contents