3. While pressing to shut each hook of the 2 resinous stands,
remove the P-Module.
6.10. Removal of Lamp Unit
1. Lift the rear side of the top panel and disconnect the top
panel Open/Close hook, then open the top panel.
2. Loosen the 3 screws until they idle.
3. Slide the lamp lock button to release, and remove the lamp
unit block (with lamp unit cover).
All manuals and user guides at all-guides.com
Note:
6.11. Removal of Analysis Block
1. Remove the upper case according to the section 6.2.
"Removal of Upper Case".
2. Unscrew the 2 screws and remove the A-P.C.Board block.
20
· When installing the lamp unit in the main unit, place
it in a specified position and press the connector
side and the opposite side of the lamp unit (arrow
positions shown in the figure below), and confirm the
lamp unit is inserted securely. Then, tighten the 3