Technical specifications
May 2022
Explosion proof enclosure:
ATEX, IECEx, and UK CA
Ex II 2 G D
Ex db ib IIB + H
Ex ib tb IIIC T135 °C Db
-4 °F (-20 °C) to 122 °F (50 °C)
Water and dust tight: IP65
6.5

RoHS directive

This device is compliant with RoHS directive 2011/65/EU, 2015/863.
6.6
Electromagnetic interference (EMI)
compatibility
Table 6-2: Immunity tests
Title
Electrostatic discharge (ESD)
Radiated electromagnetic field
Conducted disturbances
Immunity to main supply voltage
variations
Table 6-3: Emission test
Title
Radiated emission
22
T4 Gb
2
Basic standard
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-6
MIL-STD-1275B
Basic standard
IEC 61000-6-3
Level to be tested
6 kV/8 kV contact/air
20 V/m (80 MHz to 1 GHz)
10 V/m (1.4 GHz to 2 GHz)
3 V/m (2.0 GHz to 2.7 GHz)
10 Vrms (150 kHz to 80 MHz)
N/A
Level to be tested
40 dbuv/m (30 MHz -
230 MHz),
47 dbuv/m (230 MHz - 1 GHz)
Reference Manual
00809-0800-4975
Class
Like Class B of EN
55022
Emerson.com/Rosemount