Loudspeaker configurations

Syva colinear source with LF extension

In hybrid configuration with Syva Low, the Syva system bandwidth is extended down to 40 Hz and the system contour is
reinforced by 9 dB.
Syva and Syva Low are driven by the LA4X / LA8 / LA12X amplified controllers.
Coupled
The [SYVA LOW SYVA] hybrid preset enables acoustic coupling when Syva is on top of Syva Low (AutoConnect) or
within a 60 cm (24 in) distance.
To use [SYVA LOW SYVA], connect Syva and Syva Low to the same amplified controller output.
Use Autoconnect or an SP-Y1 cable. Refer to
Connecting hybrid configurations
with AutoConnect
Enclosures
Preset
Frequency range (-10 dB)
No pre-alignement delay values are required for the Syva system.
Syva user manual (EN) version 1.0
Connecting hybrid configurations
(p.19) for LA8 or LA12X.
Syva
40 Hz - 20 kHz
(p.17) for LA4X and
< 60 cm / 24 in
without AutoConnect
Syva Low
[SYVA LOW SYVA]