Arctiko Integraline ULUF P10 Operating Instructions Manual

Arctiko Integraline ULUF P10 Operating Instructions Manual

Hide thumbs Also See for Integraline ULUF P10:

Advertisement

Quick Links

OPERATING
INSTRUCTIONS
Integraline
ULUF P10 / P50 / P90

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Integraline ULUF P10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Arctiko Integraline ULUF P10

  • Page 1 OPERATING INSTRUCTIONS Integraline ULUF P10 / P50 / P90...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS Display ⊲ Keyboard INTRODUCTION ⊲ Action icons ⊲ Info events Symbols ⊲ Door warning Abbreviations ⊲ Temperature alarms ⊲ Failure events ⊲ Outcome frames ⊲ Warnings SAFETY ⊲ How to turn on device ⊲ How to turn off device Intended use ⊲...
  • Page 3: Introduction

    INTRODUCTION SAFETY INTRODUCTION SAFETY Arctiko is obligated as a supplier to ensure the Prohibition WARNING Flammable material Please take a few minutes to read and become users safety when operating one of our units. To familiar with the advantages of your unit. To meet...
  • Page 4: Handling & Transportation

    This unit is marked in compliance with the 2002/96/ damage is observed, report to the shipping avoid corrosion. CE European Directive, WASTE ELECTRICAL AND company and your local Arctiko distributor. Please see the serial plate affixed to the unit, to ELECTRONIC EQUIPMENT (WEEE). obtain information about the refrigerant.
  • Page 5: Electrical Connection

    INSTALLATION INSTALLATION Prohibition Always follow local regulations when preparing an installation. Contact your local authorities if in any Do not use the unit outdoors. Current Disconnect the power cord if there doubt. leakage or electric shock may result if the is something wrong with the unit.
  • Page 6: Product Description

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION PRODUCT DESCRIPTION The Integraline range offers the best ultra-low technology, low energy consumption, low heat temperature freezing with high performance and dissipation and excellent temperature stability. All stability. Standard features are VIP panels, filter-less units are equipped with a vacuum valve and a key construction for less maintenance, noise reduction lock on the door.
  • Page 7: Single Compressor Technology

    SINGLE COMPRESSOR TECHNOLOGY DISPLAY As standard, the unit is equipped with a The Arctiko Integraline range also comes with our Easy and user-friendly control panel, with a 6-key In the single temperature configuration two types temperature probe inside the chamber. The probe single compressor technology.
  • Page 8: Action Icons

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION HIGH TEMPERATURE ALARM 3. In case of a unresolved failure, the icon FAIL ⊲ ACTION ICONS ⊲ DOOR WARNING UNRESOLVED will be shown on the screen. ICON ACTION PAUSE icon -18° WAITING COOLING COOLING DOOR OPENED LOW TEMPERATURE ALARM 4.
  • Page 9: Warnings

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION CONFIRMED ⊲ HOW TO TURN ON THE DEVICE 1. Press on the screen and hold, to turn on the device. 3. If password protection is enabled type pasword ESC/CONFIRM and press ENTER. 2. If password protection is enabled, type password and press ENTER.
  • Page 10: Menu User

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION How to change the setpoint How to change the alarm limits ⊲ MENU USER 1. Press SETPOINT to enter the setpoint 1. Press MENU to access the user menu. adjustement. 2. Press LIMITS in the user menu. 2.
  • Page 11: Access Log

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION Access log With USER password different from zero, it is ACTUAL KEY requested to access the setting of the new Press ACTUAL/MODIFIED to retrieve the value in BLACK-OUT 1. Press ACCESS LOG from user menu to access the configuration.
  • Page 12: Menu Settings

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION ⊲ MENU SETTINGS REPRESENTATION CRITERIA The grey boxes indicate the lack of data, the green boxes the presence of data, the red boxes the presence of a discrepancy. Press the key of the requested day to access the display frame of the daily graph.
  • Page 13: How To Set Date/Hour

    The service settings are reserved for and press ENTER to confirm. 2. Activate the alarm relay for 3 seconds according qualified Arctiko service personnel. to these sequences OFF / ON / OFF 2. By entering the admin password both the admin and user passwords can be changed.
  • Page 14: Data Download

    The BACKUP menu transfers the thermoregulation data on usb pen. Pressing the BACKUP icon shows Installation and operating manual – Rel. 2.0 contacting your Arctiko distributor. the usb-pen insertion request frame with20-second time-out. If the usb-pen has been recognised, the setting page of the months to download is displayed, otherwise the display goes back to the SETTINGS 1.
  • Page 15: Rating Plate

    Company logo Contact details functionality of the unit. Arctiko recommends a cleaner. Parts of the refrigeration system of this thorough examination twice a year and cleaning at unit are completely sealed. These do not require least once a month.
  • Page 16: Service

    Arctiko strive for day-to-day delivery of spare parts. Check if there has been frequent door Frequent door openings may cause the openings. Leave the door closed until However, some special parts may take longer due temperature to rise.
  • Page 17 NOTES NOTES NOTES NOTES OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS...
  • Page 19 ARCTIKO A/S | Oddesundvej 39 | 6715 Esbjerg N | Denmark +45 70 20 03 28 | www.arctiko.com | info@arctiko.com Follow us on: We reserve the right to change specifications without notice. Subject to confirmation, availability and errors. 5080065 - 07 - GB...