  • Page 1 OPERATING INSTRUCTIONS Integraline Compact ULUF P10 / P50 / P90...
  • Page 2: Table Of Contents

    TABLE OF CONTENTS INTRODUCTION Symbols Abbreviations SAFETY Intended use Personal safety HANDLING & TRANSPORTATION Moving the unit Packaging Unpacking Inactivity for extended period Disposal INSTALLATION Preparing the unit Refrigerant Location Electrical connection Getting started PRODUCT DESCRIPTION Cabinet overview Cabinet details Cabinet description Probes and portholes Single compressor technology...
  • Page 3 Display ⊲ Keyboard ⊲ Action icons ⊲ Info events ⊲ Door warning ⊲ Temperature alarms ⊲ Failure events ⊲ Outcome frames ⊲ Warnings ⊲ How to turn on device ⊲ How to turn off device ⊲ Menu user How to change the setpoint How to change alarm limits Access log Ecomode settings...
  • Page 4: Introduction

    This unit contains flammable refrigerants. the high quality demands required by the medical and pharmaceutical industry, at least 10% of all units that leaves Arctiko are carefully checked and Grounding tested to ensure high performance and quality. If the operating and installation instructions describe Be aware that the unit is grounded.
  • Page 5: Safety

    SAFETY SAFETY Prohibition Arctiko is obligated as a supplier to ensure the users safety when operating one of our units. To Do not insert metal objects such as pins or prevent personal and material injury or damage, wires into any vent, gap ors outlet on the please follow the instructions in this manual.
  • Page 6: Handling & Transportation

    This unit is marked in compliance with the 2002/96/ damage is observed, report to the shipping CE European Directive, WASTE ELECTRICAL AND company and your local Arctiko distributor. ELECTRONIC EQUIPMENT (WEEE). 2. Remove all packaging material, plastic and straps. All packing materials are entirely recyclable.
  • Page 7: Installation

    HANDLING & TRANSPORTATION INSTALLATION PREPARING THE UNIT WARNING Flammable material • Unpack the unit: Remove all packaging materials, Do not use electrical appliances inside the plastic bags and straps. food storage compartments of the unit, unless they are of the type recommended by the •...
  • Page 8: Electrical Connection

    INSTALLATION Prohibition Always follow local regulations when preparing an installation. Contact your local authorities if in any Do not use the unit outdoors. Current doubt. leakage or electric shock may result if the unit is exposed to rain. Follow procedures Prohibition Only qualified/authorized engineers or service personnel should install the unit.
  • Page 9: Getting Started

    INSTALLATION Disconnect the power cord if there is something wrong with the unit. Continued abnormal operation may cause electric shock or fire. GETTING STARTED During the initial startup and continuous usage of the unit, the following procedures shall be followed: Plug the power socket in a dedicated outlet.
  • Page 10: Product Description

    PRODUCT DESCRIPTION PRODUCT DESCRIPTION The Integraline range offers the best ultra-low technology, low energy consumption, low heat temperature freezing with high performance and dissipation and excellent temperature stability. All stability. Standard features are VIP panels, filter-less units are equipped with a vacuum valve and a key construction for less maintenance, noise reduction lock on the door.
  • Page 11: Cabinet Description

    PRODUCT DESCRIPTION CABINET DESCRIPTION AREA DESCRIPTION Compressor compartment The compressor compartment is located in the bottom of the unit. Vacuum valve Equalizes the pressure in the unit. Door handle with lock For easy opening, closing and locking the door. Front panel Access for compressor compartment, fitted with control panel.
  • Page 12: Probes And Portholes

    PROBE AND ACCESS PORTS SINGLE COMPRESSOR TECHNOLOGY As standard, the unit is equipped with a The Arctiko Integraline range also comes with our temperature probe inside the chamber. The probe single compressor technology. In contrast to the monitors the temperature in the chamber and normal casade system, these appliances only need controls the operation of the compressors.
  • Page 13: Display

    PRODUCT DESCRIPTION DISPLAY Easy and user-friendly control panel, with a 6-key In the single temperature configuration two types resistive keyboard. You can access a variation of of Home Page are provided: EASY or SCIENTIFIC. settings, in order to adjust your unit for your exact The external ESCAPE key selects one mode or the needs.
  • Page 14: Action Icons

    PRODUCT DESCRIPTION ⊲ ACTION ICONS ⊲ DOOR WARNING ICON ACTION PAUSE icon -18° WAITING COOLING COOLING DOOR OPENED DEFROST DRIPPING -16° HEATING WARM DOOR ALARM CO2 BACKUP ⊲ TEMPERATURE ALARMS STOP ACTIONS LOW/HIGH TEMPERATURE PREALARM ⊲ INFO EVENTS ICON EVENTS ALARM ON ALARM OCCURRED FAILURE STATUS...
  • Page 15: Failure Events

    PRODUCT DESCRIPTION HIGH TEMPERATURE ALARM 3. In case of a unresolved failure, the icon FAIL UNRESOLVED will be shown on the screen. LOW TEMPERATURE ALARM 4. If any alarm has occurred, the icon NOTIFICATION OF PREVIOUS ALARM will appear on the screen. ⊲...
  • Page 16: Warnings

    PRODUCT DESCRIPTION CONFIRMED ESC/CONFIRM ⊲ WARNINGS To accept a warning press ENTER. OPERATING INSTRUCTIONS...
  • Page 17: How To Turn On Device

    PRODUCT DESCRIPTION ⊲ HOW TO TURN ON THE DEVICE 1. Press on the screen and hold, to turn on the device. 3. If password protection is enabled type password and press ENTER. 2. If password protection is enabled, type password and press ENTER.
  • Page 18: Menu User

    PRODUCT DESCRIPTION ⊲ MENU USER ICONS DESCRIPTION STAND-BY Press and hold to turn off the controller. SETPOINT Change the temperature setpoint. LIMITS Set the high/low temperature limits and alarm delay. ACCESS LIST Access log. ECOMODE Set the ECOMODE parameters. EVENTS Displays the alarms and failures recorded.
  • Page 19: How To Change The Setpoint

    PRODUCT DESCRIPTION How to change the setpoint How to change the alarm limits 1. Press SETPOINT to enter the setpoint 1. Press MENU to access the user menu. adjustement. 2. Press LIMITS in the user menu. 2. Press the UP to increase the temperature or the DOWN to decrease the temperature.
  • Page 20: Access Log

    PRODUCT DESCRIPTION Access log With USER password different from zero, it is requested to access the setting of the new 1. Press ACCESS LOG from user menu to access the configuration. The password is edited via the display of the list of the last 32 events accesses. numerical keypad and confirmed by pressing ENTER.
  • Page 21: Event List

    PRODUCT DESCRIPTION ACTUAL KEY Press ACTUAL/MODIFIED to retrieve the value in BLACK-OUT progress/preset. MAINS FAULT SX PROBE ESCAPE UNIT FAULT Press external ESCAPE key to return to the USER LOAD FAULT MENU without saving with exit/confirm request. RELAY FAULT LOW EVAPORATION HIGH CONDENSATION Event list HIGH PRESSURE...
  • Page 22 PRODUCT DESCRIPTION REPRESENTATION CRITERIA The grey boxes indicate the lack of data, the green boxes the presence of data, the red boxes the presence of a discrepancy. Press the key of the requested day to access the display frame of the daily graph.
  • Page 23: Menu Settings

    PRODUCT DESCRIPTION ⊲ MENU SETTINGS ICONS DESCRIPTION DATE/HOUR Set the clock device. DISPLAY Set the configuration of panel display. Set the 3 levels of passwords: PASSWORD ADMINISTRATOR / USER / SERVICE BACKUP Start download data through USB port. CARD FORMAT Erase the data recorded.
  • Page 24: How To Set Date/Hour

    Service: For accessing the service menu. selecting the text languages. The service settings are reserved for qualified Arctiko service personnel. 2. By entering the admin password both the admin and user passwords can be changed. The passwords can be deactivated by setting them to “000”.
  • Page 25: Alarm Test

    PRODUCT DESCRIPTION By entering the multiuser menu, multiple user accounts can be setup. This is useful for tracking which user changes parameters or turns the unit on or off. These individual user accounts can be named to easily differentiate between them. 3.
  • Page 26: Default Settings

    The program can be obtained by The BACKUP menu transfers the thermoregulation data on usb pen. Pressing the BACKUP icon shows contacting your Arctiko distributor. Installation and operating manual – Rel. 2.0 the usb-pen insertion request frame with20-second time-out. If the usb-pen has been recognised, the setting page of the months to download is displayed, otherwise the display goes back to the SETTINGS 1.
  • Page 27 PRODUCT DESCRIPTION 3. Open the file by following the path: VLX > BACKUP > R00000 (serial number of the unit) > 201807 (year and month). Choose the desired file and press Open. 4. When the convertion is complete, a window with the message “Succesful operation”...
  • Page 28: Rating Plate

    PRODUCT DESCRIPTION RATING PLATE The rating plate is placed on the front right corner of the compressor department. Company logo Contact details Model & temp. range Power Serial number Refrigerant type and charge Compressor type Climate class CE mark Global warning potential WEEE ”Waste from Electrical and Electronic Equipment”...
  • Page 29: Maintenance

    • Dust off the inside of the compressor is essential to ensure high performance and compartment using only a dry brush or a vacuum functionality of the unit. Arctiko recommends a cleaner. Parts of the refrigeration system of this thorough examination twice a year and cleaning at unit are completely sealed.
  • Page 30: Service

    Arctiko distributor. Please inform the serial number of the unit and model when contacting the distributor. Arctiko strive for day-to-day delivery of spare parts. However, some special parts may take longer due to production time. Arctiko guarantees availability of spare parts for all units for at least 10 years after the delivery.
  • Page 31: Troubleshooting

    TROUBLESHOOTING TROUBLESHOOTING Most malfunctions arise in wrong use of the unit and can often be solved on the spot. In order to resolve some of the most common malfunctions please see the following troubleshooting scheme: PROBLEM CAUSE ACTION Overload or load of warm products may Discharge warm or excess products.
  • Page 32 NOTES NOTES NOTES OPERATING INSTRUCTIONS...
  • Page 33 NOTES OPERATING INSTRUCTIONS...
  • Page 36 ARCTIKO A/S | Oddesundvej 39 | 6715 Esbjerg N | Denmark +45 70 20 03 28 | www.arctiko.com | info@arctiko.com Follow us on: We reserve the right to change specifications without notice. Subject to confirmation, availability and errors. 5080065 - 09 - GB...