Mechanical and electrical installation
Use the toggle key
10
baud rate and hold the enter key 
onds to confirm.
y Calibration law compliant Controller charging
station: Select the value 9,600
y Calibration law non-compliant controller
charging station: Select the value 38,400
Use the toggle key
11
the parity of the energy meter and briefly press the
enter key
Use the toggle key
12
and hold the enter key 
confirm.
Use the toggle key
13
the stop bit of the energy meter and briefly press the
enter key
Use the toggle key
14
stop bit and hold the enter key 
onds to confirm.
Use the toggle key
15
press the enter key
The energy meter is now set up for operation as a load management system for a group installation. The next step is
to set up the individual charging stations and the group in the ABL Configuration Software and ABL User Inter-
face applications.
to select the appropriate
for about 3 sec-
to select the PAritY menu for
.
to select the parity EVEN
for about 3 seconds to
to select the bStoP menu for
.
to select the value 1 for the
for about 3 sec-
to select End and briefly
.
≤1S
≥3S
≤1S
≤1S
≤1S
≥3S
≤1S
≤1S
≤1S
≥3S
≤1S
≤1S