Download Print this page

OCEANAIRE 2OACH1211 Engineering, Installation And Service Manual page 5

1-ton portable air-cooled heat pump1-ton portable air-cooled heat pump

Advertisement

STANDARD FEATURES
CABINET
The 2OACH1211 Series heat pump has a cabinet that is constructed of 18 gauge steel
with a polyester powder coated finish that will compliment any decor. The cool blue
front compliments any surrounding space, and is insulated with sound-absorbing
insulation for cool, quiet comfort. All units come equipped with handles and
premium swivel casters for portability and convenient set-up.
DELUXE ELECTRONIC CONTROLLER
Each 2OACH1211 unit is equipped with a deluxe electronic controller. When power is
connected to the unit, the thermostat will control the unit to cool/heat a space to the
desired temperature. The thermostat is also capable of controlling the fan to operate
automatically when needed, or continuously.
One additional feature of the Deluxe Electronic Controller is that it will display a
condition alarm "CON". "CON" displays when a condensate alarm, or a high pressure
reset condition has been met. To protect the compressor from short-cycling, there is
a built-in time delay. In the event of a power outage, all thermostat settings are
saved, and the unit will re-start automatically.
FAN SPEED CONTROL
One of the features of the electronic controller is that the unit supply fan can be
controlled either automatically or manually. In AUTO mode, the indoor blower will
adjust air flow automatically for added comfort and performance. Or, if desired, the
controller can be set to MANUAL fan mode, and the indoor blower will run continu-
ously at one of six levels of fan speed.
CONDENSATE TANK/PUMP
The 2OACH1211 unit comes equipped with a means for handling the condensate
generated during the cooling/heating process. The tank can be easily removed from
the unit and emptied as needed.
An optional automatic condensate pump (UPK-115) is available and can be factory
installed . The pump comes with a 20 foot long vinyl hose that allows for the removal
of the condensate water to a drain. The automatic pump is capable of a 20ft vertical
lift, to handle almost any installation requirement.
FILTERS
All 2OACH1211 units are equipped with washable filters at the air intakes.
Electrostatic mesh air filters located behind the evaporator return air grille serve to
filter the air before it is cooled/heated, and behind the condenser return air grille to
prevent dust build-up. Both filters can be easily removed and cleaned.
HIGH PRESSURE SAFETY SWITCH
Located on the back of the 2OACH1211 unit is a manual re-set high pressure switch,
used for the protection of the compressor. If the condensing pressure exceeds the
limit setting, the switch will cycle the compressor off, while the evaporator fan
remains running. The display will indicate the fault setting "CON". The compressor
can then be re-started, once the condensing pressure has equalized, by depressing
the "RESET" button.
POWER CORDS
All 2OACH1211 units come standard with a power cord for a convenient connection. It
is equipped with LCDI for added safety features.