Download Print this page

OCEANAIRE 2OACH1211 Engineering, Installation And Service Manual page 11

1-ton portable air-cooled heat pump1-ton portable air-cooled heat pump

Advertisement

2OACH1211 OPTIONAL ACCESSORIES
NOZZLE KIT, 2NK-1 (2 X 4")
are used to direct the conditioned air to a specific target area. By
concentrating the airflow, the nozzles increase the air velocity to-
wards production lines to cool personnel and/or equipment. In server
rooms, the nozzles can be used to direct the airflow through the rack
to remove the hot air from the area of the equipment.
EVAPORATOR RETURN AIR PLENUM, DEP-10
The evaporator return air plenum is available for installations
where it is required to duct air to the inlet of the evaporator. The
evaporator return air plenums allow the user to connect round
ducts (flexible or rigid) to the return air intake to reduce air noise
and increase the number of options for solving difficult cooling
problems. The plenum attaches to the front of the unit, replacing
the return air grille.
DISCHARGE DUCT ADAPTER, 2DDA-6
Discharge duct adapter is available for applications where
ducted evaporator discharge is required. The adapters can be
easily installed on the unit without fasteners, and be installed
for either vertical or horizontal ducting. The standard
discharge grille is removed and the 2DDA-6 is attached in the
grille opening.
CONDENSATE PUMP KIT, UPK-115
A plug-in condensate pump kit is available for
applications where emptying the 5 gallon condensate
tank is not practical. The pump kit consists of a
condensate pump with mounting hardware and
electrical connections, along with the tubing required
for the drain and discharge of the condensate water.
CEILING PANEL DUCT KIT, CK-12
A ceiling panel kit is available for discharging the
condenser air above a drop ceiling. The ceiling panel duct
kits are furnished with a white vinyl coated flexible duct
that allows for convenient installation. A 2' x 2' ceiling
duct- panel is included to replace a 2' x 2' drop-ceiling
panel where the connection is desired. The ceiling panel
kit consists of 8 feet of flexible duct, and a 2' x 2' lay in
ceiling panel.
CONDENSER RETURN AIR PLENUM, 2DCP-1
Condenser return air plenums are available for installations
where it is required to duct air to the inlet of the condenser.
The plenum easily fits into place on the back of the unit, and is
provided with a flange for connecting 12-inch flexible ducting.
A condenser return air plenum can substantially reduce air
noise and allow the unit to operate without drawing condenser
air from the conditioned space.
The optional discharge nozzle kits
9

Advertisement

loading