QB-RL78L1C In-Circuit Emulator
(c) Ensuring isolation
Adjust the height of the QB-RL78L1C with the front space adapter and the rear space adapter and ensure
isolation from the target system.
(d) Precautions related to emulation probe
<1> Be careful that stress of the emulation probe is not placed on the target connector. Moreover, when
removing the emulation probe, remove it slowly while pressing down on the exchange adapter with a
finger so that there is no stress on the target connector.
<2> Be sure to connect the GND wire of the emulation probe to the QB-RL78L1C and the target system. If
it cannot be connected, the impedance of the cable is unstable and could bring about lowering of signal
transmission characteristics or distortion of the output waveform for an input waveform.
R20UT2703EJ0200 Rev.2.00
Jan 31, 2014
Figure 2-7 Where GND Wire Can Be Connected
L = 60 mm
(J)
24.7 mm
CHAPTER 2 SETUP PROCEDURE
34.3 mm
(K)
L = 60 mm
User system