Summary of Contents for Baker Hughes Masoneilan 10900 Series

  • Page 1 Masoneilan ™ 10900 Series Spring Diaphragm and Differential Pressure Actuators for use with 500 Series Regulators Instruction Manual (Rev.D) Baker Hughes Data Classification: Public...
  • Page 2 OPERATOR ARE STRICTLY LIMITED TO THOSE EXPRESSLY PROVIDED IN THE CONTRACT RELATING TO THE SUPPLY OF THE EQUIPMENT. NO ADDITIONAL REPRESENTATIONS OR WARRANTIES BY BAKER HUGHES REGARDING THE EQUIPMENT OR ITS USE ARE GIVEN OR IMPLIED BY THE ISSUE OF THESE INSTRUCTIONS.
  • Page 3: Safety Information

    Warranty Items sold by Baker Hughes are warranted to be free from defects Indicates a potentially hazardous situation which, if not avoided, in materials and workmanship for a period of one year from the could result in death or serious injury.
  • Page 4: Description-Operation

    250 psi static pressure and a case rated for 750 psi static pressure. Baker Hughes has a highly skilled After Sales Department available for start-up, maintenance and repair of our regulators and In Differential Pressure Actuators, two actuator cases are available: a low-pressure case rated for 250 psi static pressure, components parts.
  • Page 5: Parts Reference

    Only on 0.5-3 ; 2-10 ; 6-20 and 15-40 psi ranges actuators mounted on types 526 and 536H Only on 0.5-3 ; 2-10 ; 6-20 and 15-40 psi ranges regulators Only on 150-750 psi range Masoneilan 10900 Series Actuator Instruction Manual | 5 Copyright 2020 Baker Hughes Company. All rights reserved.
  • Page 6: Installation

    In the Spring Diaphragm Actuators, the 1/2” NPT pressure connection is located on the upper diaphragm case (13). 6 | Baker Hughes Copyright 2020 Baker Hughes Company. All rights reserved.
  • Page 7: Maintenance

    Note: By means of a wrench applied on the plug stem Uniformly tighten all diaphragm case nuts (16) when nuts, hold the actuator stem during this operation. reassembling. Masoneilan 10900 Series Actuator Instruction Manual | 7 Copyright 2020 Baker Hughes Company. All rights reserved.
  • Page 8 Copyright 2020 Baker Hughes Company. All rights reserved. Baker Hughes provides this information on an “as is” basis for general information purposes. Baker Hughes does not make any representation as to the accuracy or completeness of the information and makes no warranties of any kind, specific, implied or oral, to the fullest extent permissible by law, including those of merchantability and fitness for a particular purpose or use.