Wiring Diagrams ......................6 Step 3 - Thermostat Mounting ................ 9 Step 4 - Initial Setup ..................10 Welcome to the Terra thermostat ..............11 How to quickly change the temperature .............. 11 How to quickly change mode ................. 11 Heating ......................
Safety Information The thermostat must be installed by a qualified electrician. It requires a permanent 110V - 240V AC, 60Hz supply. The thermostat contains a Class A GFCI with 5mA trip level and wiring must conform to local electrical code. Isolate the thermostat from the mains supply throughout the installation process.
Step 2 - Wiring Connections WARNING! The thermostat must be installed by a qualified electrician in accordance with National Electrical Code. Wiring Connections LOAD Heater Load Max.15A L1 & L2 (1800W - 120V, 3600W - 240V) LINE Supply Live (120 V) LINE Supply Neutral (120 V) / Supply Live (240 V) Probe 1 -...
Page 5
Table 1.0 Thermostat Use Cases Use Case Control Limit Sensor Thermostat IN room Internal Air temperature schedule None Air Sensor No floor limit Thermostat IN/OUT of room P1 & PC Floor temperature schedule None Floor Sensor Floor limit Thermostat IN room P1 &...
Wiring Diagrams Heating loads connected to thermostat Heating ≤ 3600W/15A Heating ≤ 3600W / 15A into thermostat only Option 1 R C Snubber not required RED - Hot 120V / White - Neutral Heating, RED - 240V, Yellow - 120V Heater earth connections should be connected to earth in line with NEC, CEC code.
Page 7
Wiring Diagrams Heating loads connected to Relay-25 Snubber Relay 1 ≥ 15 A 6mA GFCI 20 A Heating ≤ 3600W/15A Heating ≤ 3600W / 15A into external relay only Option 2 R C Snubber required RED - Hot 120V / White - Neutral Heating, RED - 240V, Yellow - 120V Heater earth connections should be connected to earth in line with NEC, CEC code.
Page 8
Wiring Diagrams Heating loads connected to thermostat and Relay-25 Snubber Heating ≤ 3600W/15A Relay 1 ≥ 15 A 6mA GFCI 20 A Heating Relay # ≤ 3600W/15A ≥ 15 A 6mA GFCI 20 A Heating ≤ 3600W/15A Heating ≤ 3600W / 15A into thermostat Heating ≤...
Step 3 - Thermostat Mounting 1,500W Insert fixing screws through Re-attach the front housing until a mounting holes of the power base “click” is heard. You can now power and tighten. up the thermostat. Thermostat WiFi Setup System Input Input application Open type...
Step 4 - Initial Setup ‘MyHeating’ by Warmup Download the MyHeating App. Open the MyHeating App and scan the QR Code on the thermostat screen protector or on reverse of the display. Follow the instructions in the App to complete setup.
Welcome to the Terra thermostat Next/Accept Back/Cancel Up/Down Change value/setting How to quickly change the temperature Press to change your target temperature. If in program mode this will set a temporary override until your next heating period. See “How to set a temporary override”.
Heating How to set a program Setting a program allows you to set comfort temperatures at set times throughout the day. Days can programmed individually, all days the same or weekdays as a block and weekends as a block, the choice is yours. Edit Program To select the days you wish to program press...
Heating How to set into Manual Mode Setting into manual mode allows you to set a fixed target temperature for the thermostat to achieve. The thermostat will continue to maintain this temperature until another operating mode or temperature is selected. °...
SmartGeo How SmartGeo works SmartGeo is a unique technology developed by Warmup and built into the MyHeating App that uses an advanced algorithm to understand the most efficient heat settings for your home. Working automatically; it learns your...
Settings Date and time Set the current date and time. Press to begin, 6-5-2021 press to change date/time. 13:00 Press to confirm. Thermostat application Swaps probe usage, 1 being the Control Sensor Probe and 2 being the Limit Sensor Probe. Press to swap probe usage.
Page 16
Settings cont’d Change homescreen override color Select the override color. Open window function The windows open detection feature is designed to switch off heating to save energy when the thermostat detects that a window or door has been opened. Display lock Switch display lock on.
Notifications & Error codes Date and time needs to Heating switched OFF be set. Open window function Display locked triggered. Temporary override Sensor P2 (6 & 7) error enabled Sensor P1 (5 & 6) not - - - Holiday mode enabled. connected / damaged or (Configured in MyHeating App) Internal air sensor fault...
Page 18
If correctly wired please conduct a resistance test and insulation resistance test on the heater to see if damage has occurred. Relay icon Relay error The thermostat has detected that one of the relays has FAILED. Please contact Warmup GFCI...
10-15 seconds now work as reattach. Does the thermostat normal connect to your WiFi Network? Contact Warmup If the thermostat connected Set up a mobile hotspot using with your router to a mobile hotspot a smartphone. On a separate make &...
Technical Specifications Model RSW-XX-YY-ZZ Operating Voltage 110V - 240V AC +/-15% 50Hz/60Hz Protection Class 15A resistive Max. Load (120 V - 1800W, 240 V - 3600W) GFCI Class A GFCI with 5mA trip level Rated impulse voltage 4000V Automatic action 100,000 Disconnection means Pollution degree...
Warmup heater. If at any time during the warranty period the product is determined to be defective, Warmup shall repair or replace it, at Warmup’s option. If the product is defective, please either; Return it, with a bill of sale or other dated proof of purchase, to the place from which you purchased it, or Contact Warmup.