Download Print this page

Daikin RKN18NMVJU Service Manual page 11

18000 btu/h class
Hide thumbs Also See for RKN18NMVJU:

Advertisement

Si001556E
Step
11 Disconnect the
connector [S40].
12 Disconnect the
connector [S30].
13 Disconnect the
connector [S90] and
pull out the clamp.
14 Remove the screw and
remove the electrical
box.
Removal Procedure
Procedure
[S40]
[S90]
Electrical box
[S40]: overload protector
(R21890)
[S30]: compressor motor
[S30]
(R21891)
[S90]: thermistors
Clamp
(R21892)
(R21893)
Electrical Box
Points
9