Electrical Box
Step
7
Remove the 2 screws
and remove the conduit
mounting plate.
8
Remove the 2 screws.
9
Disconnect the
connector [S20].
10 Disconnect the 2
connectors from the
reactor.
8
Procedure
[S20]
Connector
When reassembling, be sure
to fit the 2 hooks on the
conduit mounting plate to the
right side panel.
Conduit
mounting
plate
(R21886)
(R21887)
[S20]: electronic expansion
(R21888)
When reassembling, you
can reconnect the 2
connectors for the reactor in
either way regardless of the
color.
Reactor
(R21889)
Si001556E
Points
Hook
(R21918)
valve coil
Removal Procedure

Advertisement