Page 39
catalog 1. Intended use、Model、Applicable strip、Test Principle 1.1 Intended use 1.2 Model 1.3 Applicable test strip 1.4 Test Principle 2. Structure and Diagram of Meter and Accessories 2.1 Main structure composition 2.2 Diagram of Meter and Accessories 3. Display 4. Operation 4.1 Changing Battery 4.2 Meter set up 4.3 Blood Glucose Testing...
Page 40
7. Bluetooth 8. Preservation and Maintenance 9. Warranty 10. Matters need attention 11. Contraindications 12. Troubleshooting 13. Performance 14. Specification 15. Accessory list 16. Explanation of symbols 17. EMC Statement 17.1 Guidance and manufacturer’s declaration -electromagnetic emission 17.2 Guidance and manufacturer’s declaration -electromagnetic immunity 17.3 Guidance and manufacturer’s declaration -electromagnetic immunity...
TRUE METRIX、TRUE METRIX AIR。 1.3 Applicable test strip TRUE METRIX blood glucose test strip(if need to buy test strip, contact sinocare or its authorized dealer to obtain it) 1.4 Test Principle Blood glucose test strip reaction zone has specific chemicals, glucose in whole blood sample react with these chemicals and produce an electrical current.
(optional), USB cable (optional). Note: Docking station (optional) only apply to 真睿TRUE METRIX、真睿TRUE METRIX AIR. USB cable (optional) only apply to 真睿TRUE METRIX GO. 2.2 Diagram of Meter and Accessories 2.2.1 真睿TRUE METRIX、真睿TRUE METRIX AIR Schematic diagram ①...
Page 43
⑥ Docking Station Contacts ④ Battery Door (It is used for data transmission with PC after connecting Docking station. Docking station is an optional accessory. If you need to buy Docking station, please contact sinocare or its authorized dealer to obtain it )
Page 44
2.2.2 Lancing device adjustable comfort tip button spring cover Lancing device (optional) Please refer to lancing device instruction of use for more information. Note: Blood glucose meter can only use with matched strip. Do not use with other product.
3.Display Full screen display 1.Result is from Memory 7.Battery Symbol 2.Time, Date 8.Alternate Site (ALT) Symbol 3.Bluetooth Symbol 9.Drop Symbol (only for 真睿 TRUE METRIX 10.Temperature Symbol AIR) and Event Tag Symbols 11.Test Reminder Symbol 4.Average value symbol 12.Ketone Test Alert Symbol 5.Test Result 13.Units Symbol 6.Control Symbol...
Page 46
Waiting for apply During testing Blood glucose sample test result (example) Control solution Event tag Test reminder on test result (example) Test reminder off Ketone alert on ALT testing Setting year Setting date Setting time...
Page 47
(Only for 真睿TRUE METRIX AIR) Blood glucose test Control solution test Bluetooth result in memory result in memory function on (sample) (sample) (Only for 真睿 TRUE METRIX AIR) Bluetooth Temperature error Invalid Hematocrit function off Too cold/Too hot (Only for 真睿 TRUE METRIX AIR)
Page 48
Sample not detected Used test strip or used wrong Meter error or apply the test strip sample error Test strip removed Test strip error Communication error during test. Out of range - Low battery Broken Display High results > 33.3 mmol/L Out of range - Low results <...
4.Operation 4.1 Changing Battery Do not recharge battery. USB cable is only for data transmission. Do not use USB cable to recharge. Battery may explode if mishandled. Do not dispose of battery in fire. Do not take apart or attempt to recharge battery. Don't throw away, dispose according to local regulations.
Meter comes with pre-set time and date. The Event Tags, Ketone Test Alert and all Test Reminders are off. Bluetooth function is initially turned on (only for 真睿 TRUE METRIX AIR). Before using the meter for the first time or after a battery change, please check the time, date.
Page 51
After turning on or off the Bluetooth Smart feature (for 真 睿TRUE METRIX AIR meter) or after setting the year (for 真睿 TRUE METRIX meter) , press “ ” or “...
Test Reminder Up to four Test Reminders per day may be set. Meter reminder sounds at set time for 10 seconds. Test reminders are initially turned off. 1. After pressing “•” Button to set Ketone Test Alert, display shows first Reminder setting. Press “ ”...
Page 53
2. Allow vial of test strips and meter to adjust to room temperature for 10 minutes. 3. Clean hands and area to be lanced with an approved disinfectant. Dry thoroughly. 4. Remove one test strip from vial. Close vial immediate- ly.
12. Hold meter with test strip pointing down. Press Strip Release Button to discard test strip in the appropriate container. Meter turns off. Result is stored in Memory. The used test strip and lancet should be treated as medical waste. Note: -If test strip has been out of the vial too long before testing, an error message appears.
Page 55
, When the 501th blood glucose test result is stored, the earliest blood glucose test result is automatically covered. Meter stores 1000 results for 真睿 TRUE METRIX AIR meter. When the 1001th blood glucose test result is stored, the earliest blood glucose test result is automatically covered.
5. Power saving function 1. The waiting time for applying sample is about 2 minutes, the error of E-2 is given if over time, and the mater turns off automatically after about 10 seconds. 2. After the test result appears, if the test strip is not pulled out and there is no operation, the mater turns off automatically after about 2 minutes.
Note: The Automatic Self-Test does not take the place of running a Control Test. 1. Insert a test strip into the Test Port. 2. If the blood glucose meter works normally, the blood glucose meter will display in full screen, the time will be displayed on the top of the screen, and the symbol of blood drop will blink, check for missing segments.
Page 58
6.2.2 How to Test Control Solution Use ONLY 真睿 TRUE METRIX Control Solution for Control Test. 1. Check dates on control solution label and test strip vial label. Do not use control solution if control solution - 3 months after opening or date next to on label (whichever comes first), and test with a new blood glucose control solution.
And according to medical waste disposal. Meter turns off. Recap control solution bottle tightly. 7. Bluetooth 真睿TRUE METRIX AIR glucose meter has Bluetooth communication function. The Bluetooth function can be turned on or off by setting the blood glucose meter. When the Bluetooth function...
When the Bluetooth connection is successful, the blood glucose meter will upload the test result to Bluetooth device. Bluetooth device will display the test result when upload successfully; and the test result will be flicker at most 5 seconds before the blood glucose meter power off when upload failed In the state of result query, if the Bluetooth connection is successful, the historical results stored by the glucose meter...
5. Never put Meter in liquids or allow any liquids to enter the Test Port. 9. Warranty Only Sinocare or Sinocare 's agency can inspect or supply any spare parts. In normal use, if the product fails, the company promises 10 years warranty.
plan without consulting a doctor or healthcare professional. When you use this blood glucose meter to get test results inconsistent with the symptoms, you should immediately go to the hospital for examination. 5.DO NOT perform testing on the critically ill or newborn. 6.
Page 63
1. After inserting test strip, meter does not turn on. Reason Action Test strip inserted upside Remove test strip. down or backwards Re-insert correctly. Remove test strip. Re-insert Test strip not fully inserted test strip fully into meter Test strip error Repeat with new test strip.
Page 64
3. Error messages Display Reason Action Repeat with new test strip, using capillary whole blood from Invalid Hematocrit the finger. If error persists, contact for assistance. Move meter and test strips to area between5°C-40°C, Temperature error wait10 minutes for Too cold/Too hot system to reach room temperature before testing.
Page 65
Display Reason Action Contact for Meter error assistance. Retest with new test Test strip error strip. If error persists, contact for assistance. Retest with new test strip. Make sure Test strip removed result is displayed during test before removing test strip. Communication Contact for assistance.
Page 66
Display Reason Action Change new Low battery battery. Do not use meter for Broken Display testing. Contact for assistance. Retest with new test Out of range - strip. If result is still “Hi”(High) contact High results > doctor or healthcare 33.3 mmol/L professional immediately.
13. Performance Accuracy and repeatability criteria for this product is refer to national standard GB/T19634-2005 In vitro diagnostic test systems -General technical requirements for blood-glu- cose monitoring systems for self-testing and International standard EN ISO 15197:2015 In vitro diagnostic test systems —Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus.
Page 68
Battery Life: Approximately 1000 tests or 1 year Manufacture date: Refer to meter label Software release: 真睿 TRUE METRIX meter: V02 真睿 TRUE METRIX AIR meter: V02 Memory Size: 500 glucose results and 1 control result for 真睿 TRUE METRIX meter 1000 glucose results and 1 control result for 真睿...
Page 69
Size: 87mm×55mm×18mm Operating Range: Relative Humidity: 10%-80%RH (Non-condensing), Temperature: 5℃- 40℃ Storage and transportation conditions: 10%-93%RH (Non-condensing), -20℃-55℃ Hematocrit: 20%-70% Altitude: Up to 3108 meters Network security: 1. Data interface Serial port communication is adopted between the TRUE METRIX AIR glucose meter and the data transmission module. There are 8 data bits, 1 stop bit, no check, no flow control, and the baud rate is fixed at 9600bps.Data is transmitted in hexadecimal format.
15. Accessory list Lancing device: 1 pcs, product which already get registration certificate. Operation method please refer to lancing device instruction of use. Battery: One 3V lithium battery #CR2032 (non-recharge- able). Details please check “4.1 Changing Battery”. Docking station (Optional) 16.
Page 71
Note: (1) In dry environment, especially with artificial material (artificial textile. carpet), using this meter may cause electro- static discharge and lead to incorrect result. (2) Portable device or mobile radio emission device may effect performance of this meter. (3) Do not use this meter near substantial radiation source (such as non-shielded RF sources), otherwise may effect performance of this meter.
17.1 Guidance and manufacturer’s declaration- electromagnetic emission Guidance and manufacturer’s declaration- electromagnetic emission The equipment is intended for sue in the electromagnetic environment specified below. The customer or the user of the equipment should assure that it is used in such an environment. Electromagnetic Emissions test Compliance...
17.2 Guidance and manufacturer’s declaration- electromagnetic immunity Guidance and manufacturer’s declaration- electromagnetic immunity The equipment is intended for sue in the electromagnetic environment specified below. The customer or the user of the equipment should assure that it is used in such an environment. Immunity Compliance Electromagnetic...
Page 74
17.3 Guidance and manufacturer’s declaration- electromagnetic immunity Guidance and manufacturer’s declaration- electromagnetic immunity The equipment is intended for sue in the electromagnetic environment specified below. The customer or the user of the equipment should assure 。 that it is used in such an environment. Compliance Immunity Test level...
17.4 Recommended separation distances between portable and mobile RF communications equipment and the equipment Recommended separation distances between portable and mobile RF communications equipment and the equipment The equipment is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the equipment can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment and the equipment as recommended below, according to...
Page 76
China type 2 diabetes blood glucose control range (《China type 2 diabetes prevention guideline》2017) State Range 4.4~7.0mmol/L Preprandial plasma glucose (79 mg/dL~126 mg/dL) (before meal) Gestational diabetes mellitus (GDM) glucose control range (Gestational diabetes mellitus prevention guideline(2014)) State Range Preprandial plasma glucose ≤5.3mmol/L(≤95mg/dL) (before meal) Normal glucose range...
Page 77
Hazardous substance and content in product Hazardous substance Component Lead(Pb)and Mercury(Hg)and Cadmium(Cd)and its compound its compound its compound ○ ○ ○ Meter case ○ ○ ○ Hardware ○ ○ ○ PCB board Electronic × ○ ○ components Hexavalent polybrominated polybrominated chromium and biphenyls diphenyl ethers...
Page 78
Hazardous substance and content in product Hazardous substance Component Lead(Pb)and Mercury(Hg)and Cadmium(Cd)and its compound its compound its compound *power line or ○ ○ ○ power adapter ○ ○ ○ *battery ○ ○ ○ *test strips ○ ○ ○ * Lancing device Packaging and ○...