Blood Glucose Monitoring System Blood Glucose Meter User Manual Safe-Accu 2 No. 265, Guyuan Road, Hi-Tech Zone, Changsha, Hunan Province, 410205,People’s Republic of China TEL:+86-731-89935581/89935582 Email:info@sinocare.com Website:www.sinocare.com Shanghai International Holding Corp. GmbH (Europe) Eiffestraße 80, 20537 Hamburg, Germany. Tel: +49-40-2513175 Fax: +49-40-255726 E-mail: shholding@hotmail.com...
Page 3
Dear Safe-Accu 2 Meter Owner Dear Owner: Sinocare thanks you for choosing the Safe-Accu 2 blood glucose monitoring system. This user manual contains important information about the meter and how it works. Please read this user manual carefully before using your new meter, or the protection provided by the meter may be impaired.
Important Health-Related Information ……………………………………………………4 Maintenance……………………………………………………………………………33 About Your Safe-Accu 2 Meter ……………………………………………………………6 Changing the batteries……………………………………………………………………34 Button Functions ……………………………………………………………………………8 Troubleshooting …………………………………………………………………………35 Setting Up Your Safe-Accu 2 blood glucose meter ……………………………………9 Explanation of symbols …………………………………………………………………41 Control Solution Testing……………………………………………………………………16 Warranty…………………………………………………………………………………42 Blood Glucose Testing ……………………………………………………………………19 References………………………………………………………………………………42 Viewing test result …………………………………………………………………………25...
The Safe-Accu 2 Blood Glucose Monitoring System is intended for in vitro diagnostic use and should not be used for the diagnosis of or screening of diabetes. The Safe-Accu 2 Blood Glucose Monitoring System includes:...
▶ Do not use other test strips and control solutions with the Safe-Accu 2 meter. ▶ Do not use the meter if it is not working properly, or there is any damage. ▶ Keep the Safe-Accu 2 test strip vial away from children. The strip vial, test strips, and Important Health-Related Information control solution bottles can be choking hazards.
FOR Safe-Accu 2 meter: 1. If test results greater than 600 mg/dL(33.3mmol/L), the meter will display “HI”, About Your Safe-Accu 2 Meter retest your blood glucose immediately with a new test strip. If your reading is still “HI”, contact healthcare professional immediately.
Full Screen Display Button Functions Button Function Action Blood drop symbol To turn the meter on and enter the blood Press and hold for 3 seconds. glucose test result review mode. To turn the meter off. Press and hold for 3 seconds. In test results review mode, press and ▲...
Setup steps for date/time Flashing Year The Safe-Accu 2 blood glucose meter is preset with the date and time. You may need to adjust it to your local time zone. Check the date and time each time the batteries are replaced.
Page 10
STEP 4: Setting the Month STEP 5: Setting the Day The month appears flashing at the lower left The year appears flashing at the top right side side of the meter display. of the meter display. 1. Press and release ▼ or ▲ to increase or 1.Press and release ▼...
Page 11
STEP 6: Setting the Hour STEP 7: Setting the Minutes The month appears flashing at the lower left The year appears flashing at the top right side side of the meter display. of the meter display. 1. Press and release ▼ or ▲ to increase or 1.Press and release ▼...
Unit of Measure is factory preset to mg/dL or mmol/L. It cannot be changed by the user. Important Information • Use only Sinocare blood glucose control solution with your Meter. • Check the expiration date on the control solution bottle. Do not use if expired.
Page 13
STEP 2: Insert a Safe-Accu 2 Test Strip Probable Cause Action Insert a Safe-Accu 2 Test Strip with printing face up and the contact end into the test strip port until it cannot go any further. The blood glucose meter will turn on. Operation mistake Retest according to correct steps Attention: Only when meter display flashing blood drop symbol “...
Blood Glucose Testing STEP 4: Twist and pull to remove the lancet protector. Retain the lancet protector for safe Prepare meter, strip, lancing device and lancet before test. lancet disposal. STEP 1: Wash your hands or use an alcohol swab to clean the fingertip.
Page 15
Reinsert the strip and begin test. The Sinocare lancing device is prepared and ready to lance your finger for a blood sample. If the meter display “E-2”, it means the environment temperature is beyond 40℃ or The lancet is for single use only.
Page 16
STEP 11: When the meter screen displays a flashing STEP 12: After a 10-second count down, the meter blood symbol, apply the blood sample to the reaction displays the test result in mg/dL or mmol/L. chamber. mg/dL If the meter displays “E-3”, please read the blood glucose testing section carefully and use a new test strip test again.
10, your blood glucose results appears along with the unit of measure. This blood The Safe-Accu 2 meter stores 200 blood glucose test results. You can review the individual glucose result is stored in the meter memory. results by entering the memory mode. Once 200 results are in memory, adding a new result Turn the meter off by removing the Safe-Accu 2 causes the oldest one to be deleted.
Press ▲ once, the screen will display the 14-day average of your blood glucose test result. No test results saved. Press ▲ twice, the screen will display the 28-day average of your blood glucose test result. Press ▲ three times, you will see the last test result displayed.
Information for Healthcare Professional Use Comparing Meter with Laboratory Results ・ Only trained healthcare professional be allowed to use Safe-Accu 2 blood glucose When comparing results between Safe-Accu 2 blood glucose monitoring system and a monitoring system on multiple patients.
Weight 77.2g,with battery Performance Characteristics Power source 3V DC,10mA,2 AAA alkaline batteries Accuracy: 95% test result of Safe-Accu 2 meet the requirement below: Memory 200 blood glucose test results Concentration Range Bias% Operating condition 10℃~35℃...
Immunity to electrostatic is charge meets the requirements of IEC 61326-2-6: 2012. The Additional features meter has been tested for radio frequency interference at the frequency range and test Auto electrode inserting detection levels specified by IEC 61326-2-6: 2012. ・ Do not use this instrument in close proximity to sources of strong electromagnetic Auto sample loading detection radiation, as these may interfere with the proper operation.
Troubleshooting Display What it means What to do Display What it means What to do Your result is below the Test method error: insert strip into Use a new test strip to test again, if Insert test strip into meter before measurement limit, which is less meter still display “LO”, call meter after apply sample to strip.
Page 23
If still on after inserting a Test strip exposed in air too long Finish the test immediately after no display, call Sinocare customer test strip after opening the vial or package taking out a test strip from a vial service at +86-731-89935581/ or package;...
Page 24
USE-BY date. at +86-731-89935581/ (>3.9 mmol/L)and ≤ LED light malfunction +86-731-89935582 126 mg/dL(≤ 7.0 Meter or test strip malfunction Call Sinocare customer service at or contact your local dealers. mmol/L), but no green +86-731-89935581/ light on +86-731-89935582 Test result is≤70mg/dL or contact your local dealers.
Keep dry Consult instructions for use Safe-Accu 2 blood glucose monitoring system: 1. Changsha Sinocare Inc. warrants this meter to be free of defects in materials and Caution Keep away from sunlight workmanship from the date of purchase. If the meter does not work properly, Sinocare will replace it with a new meter or equivalent product free of charge.
Index Normal blood glucose range…4 Thank you for choosing Safe Accu 2 blood glucose meter, Control solution, test…16 a free replacement under normal operation is provided.Please Prepare, lancing device…19 Test result, reviewing…8 do complete the warranty card and send it back to our agent or Test result, memory …26 our factory.we will inform you with information of the meter.
Need help?
Do you have a question about the Safe-Accu 2 and is the answer not in the manual?
Questions and answers