Maintenance; Troubleshooting - Sealey SAC7000 Quick Start Manual

7,000btu/hr portable air conditioner/ dehumidifier/air cooler

Advertisement

6.6.
CONTINUOUS DRAINAGE
To provide a more efficient performance the self-evaporating system uses the collected water
to cool the condenser coils.
It is recommended not to use the continuous drain method in the cooling mode.
The condensate water evaporates at the condenser and is expelled through the exhaust hose.
6.6.1.
Switch off the unit and remove the electrical plug from it's power source.
6.6.2.
Release the cover from the water outlet opening (fig.13).
6.6.3.
With care push fit one end of the drain hose onto the water outlet (fig.13).
6.6.4.
Securely place the other end of the drain hose over a suitably sized container or drain.
WARNING! Ensure that the drain hose is straight and free from any kinks and at an inclination
angle downwards of not more than 20º.
DO NOT allow the open end of the drain hose to be submerged into the water. This may cause
8
an air lock in the hose.
NOTE: The condensate water will automatically flow into the container or drain.

7. MAINTENANCE

NOTE: Maintenance, service and repair must be carried out by qualified person. Contact your Sealey stockist for details.
7.1.
CLEANING
7.1.1.
Switch off the unit and remove the electrical plug from it's power source.
7.1.2.
Clean the unit with soft damp cloth.
DO NOT use solvents.
8
7.2.
CLEANING THE AIR FILTER
The air filter requires regular cleaning. A restricted airflow will reduce the efficiency of the system.
It is recommended that air filter is cleaned every two weeks.
DO NOT operate the unit without an air filter.
8
7.2.1.
Switch off the unit and remove the electrical plug from it's power source.
7.2.2.
Remove the filter mesh from the unit (fig.1 #4).
7.2.3.
Use a household vacuum to remove any dust from the filter.
7.2.4.
Turn the filter over and rinse the filter under running water (fig.14).
7.2.5.
Allow the filter to dry before reinstalling.
8. STORAGE
8.1.
Turn on the unit and select the low wind ventilation mode. See section 6.2.4.
8.1.1.
Leave in this condition until the drainage pipe becomes dry.
NOTE: This will help prevent mildew.
8.2.
Switch off the unit and remove the electrical plug from it's power source.
8.3.
Remove the window kit, exhaust hose and drain hose.
8.4.
Drain the remaining water from the unit. See section 6.5.
8.5.
Replace any drainage plugs.
8.6.
Clean the filter. See section 7.2.
8.7.
Remove the batteries from the remote control.
8.8.
Store the unit and accessories in it's original packaging, in safe dry childproof location.

9. TROUBLESHOOTING

SYMPTOM
The unit is not
No power
working
Full water indicator is illuminated
Low room temperature
The unit works
Dirty air filter
with reduced
Air ducts are blocked
capacity
Doors or windows open
Incorrect mode and temperature selected
Detached exhaust hose
Water leakage
Spillage when moving the unit
The drain hose is kinked or bent
Excessive noise
The unit is on an uneven surface
Loose, vibrating parts
Water flowing sound
Error
E0
Communication faults between main PCB and
codes
display PCB
E1
Ambient temperature sensor fail
E2
Coil temperate sensor failures
Ft
Condensate water high level alarm
© Jack Sealey Limited
POSSIBLE CAUSE
Original Language Version
fig.13
REMEDY
Connect to power source and turn the unit ON
Drain the water
Change the set temperature
Clean the air filter as required
Clear obstacles. Re-position unit into clear space
Close the doors and windows
Select correct mode and temperature to suit desired
application
Securely reattach exhaust hose
Empty the water tank before moving the unit
Straighten the drain hose
Place the unit onto a flat horizontal surface
Check for loose parts and re-tighten
Normal sound of refrigerant flowing
Contact Sealey service centre
Contact Sealey service centre
Contact Sealey service centre
Drain the water
SAC7000 Issue 3 (3) 15/06/22