Download Print this page

Lock4Safe DUET DU4020 Manual

Advertisement

Quick Links

DUET
DU4020 / DU4050
Technical Description/Installation Instruction
Characteristics
The Duet © combines an electronic safe lock and a mechanical Combination lock in one housing. The
operator uses the advantages of both Systems. The lock has the standard mounting dimensions
(66,5x41mm) and can be mounted in all 4 mounting positions. (RH, LH, VU, VD)
The lock can be mounted in typical security containers.
Dimension: 85 mm x 61 mm x 37 mm. NOTE: Because of the electronics, the housing is 5-8 mm
thicker than a normal combination lock.
Lock bolt: 25mm x 8mm with 2 holes (ready to tap M4 if required). The throw is 8mm. Max bolt force
10N.
The lock may be mounted with the "DuetInput" DIxxxx as shown in this instruction or with any
approved entry unit and separate dial. The lock is driven by a 4,7 mm (3/16 inch) square spindle, a
spline key is not required. The distance between change and opening index is 8 ¼ numbers.
The construction of the security container needs to include protection against destructive force from
outside and should not give access to security relevant parts of the lock even with open door.
Installation dimensions
The diameter of the hole for cable and spindle should be minimal 8mm, maximal 12mm. Deburr the
spindle hole to avoid damage to the cable.
The cable does not move or wear when using the lock. However, the installer needs to take care that
the cable is not touching moving parts. For new constructions and if possible, it is advised to create a
separate hole for the cable. If spindle and cable share the same hole, use the plastic tube over the
spindle only to separate it from the cable.
DU40•20 Technical Manual EN 150624
Page 1 of 4
© 2015 www.Lock4Safe.com

Advertisement

loading

Summary of Contents for Lock4Safe DUET DU4020

  • Page 1 For new constructions and if possible, it is advised to create a separate hole for the cable. If spindle and cable share the same hole, use the plastic tube over the spindle only to separate it from the cable. DU40•20 Technical Manual EN 150624 Page 1 of 4 © 2015 www.Lock4Safe.com...
  • Page 2 The lock bolt must move freely into the cavity. Turn the dial several times to assure that it turns freely. DU40•20 Technical Manual EN 150624 Page 2 of 4 © 2015 www.Lock4Safe.com...
  • Page 3 If change key cannot be inserted or turned, the correct code has not been dialed to the Changing Index on the dial. Take out the key and dial the valid code again. DU40•20 Technical Manual EN 150624 Page 3 of 4 © 2015 www.Lock4Safe.com...
  • Page 4 3. Turn cam counterclockwise until lock opens. The cam should be lined up with the “LOCK OPEN” line on the cover (see figure 2). Fig 1 Fig 2 Do not deviate from this instruction as it is part of the VdS certification. DU40•20 Technical Manual EN 150624 Page 4 of 4 © 2015 www.Lock4Safe.com...