  • Page 1 Pulse PRO High security lock for safes User Manual 180105...
  • Page 2: Table Of Contents

    Time delay (function 9) ............9 Set Date and Time ............... 10 Download Audit (Function 7)..........11 System settings (function 6) ..........12 Lock configuration (function 8) ..........13 Configurations-Numbers Tables A, B, C & D ......13 L4S User Instructions Pulse PRO EN 180105...
  • Page 3: Information About Pulse Pro

    Information about Pulse PRO Keypad For security reasons the keypad will automatically switch off if no operation is performed for 5 seconds. If a wrong operation is made, wait 5 seconds until the keypad switch off. Function Keys Important functions are accessible by function keys. Press and hold the button for approximately 2 seconds until the LED stays on permanently.
  • Page 4 A long beep and the message “BATTERY LOW” indicate the battery i slow and has to be immediately changed. Audit The lock stores the last 5500 operations with time, date, user and operation. L4S User Instructions Pulse PRO EN 180105...
  • Page 5: Open The Lock

    Enter valid ID and current Code (followed by electronic key if required). Double signal. Enter the new code without ID. (followed by electronic key if required). Double signal. Repeat new code. Double signal. In case of error the old code remains valid. www.lock4safe.com...
  • Page 6: Battery Test (Function 4)

    A damaged button will cause a long beep and the lock exits the function In case the unit emits a buzzing sound after opening, the Date and Time settings need to be adjusted. (See chapter on page 10) L4S User Instructions Pulse PRO EN 180105...
  • Page 7: Add Codes (Function 1)

    2 seconds until double signal and LED remains ON. Enter a valid Manager code. Double beep. (Some configurations require a second code to be entered „4-eyes“) Enter the ID of the user which must be deleted. Double beep and LED goes off. www.lock4safe.com...
  • Page 8: Code Status (Function 7)

    Press and hold for approx. 2 seconds until double signal and LED remains ON. Enter your personal ERC code. LED flashing. A double signal means operation done. LED goes off. L4S User Instructions Pulse PRO EN 180105...
  • Page 9: Time Delay (Function 9)

    Enter Value in minutes for the “open window” period. 00 to 19 minutes. Double signal if values accepted. Repeat value in minutes for the waiting period (00 to 99). Repeat value in minutes for the open window (01 to 19). Double-Signal und LED goes off. www.lock4safe.com...
  • Page 10: Set Date And Time

    Note! Enter only the last two digits of the year. Double signal if values accepted. Repeat date values. Double-Signal und LED goes off. * Date format can be changed in system settings (see chapter on page 12) L4S User Instructions Pulse PRO EN 180105...
  • Page 11: Download Audit (Function 7)

    ON. Enter a valid Manager or Master code. Double beep. Press . LED is flashing. Start the download by pressing ”download” in the Audit software While download in progress, LED is flashing. LED goes off when download is finished. www.lock4safe.com...
  • Page 12: System Settings (Function 6)

    = MM/DD/YY = OFF* Enforce Code Change: = OFF ON or OFF* = ON After month = OFF* = OFF Disable unused codes: ON or OFF* = ON After month * = Factory setting L4S User Instructions Pulse PRO EN 180105...
  • Page 13: Lock Configuration (Function 8)

    Up to 50 Table C , Up to 50 plus 10 Override codes  Table D Additionally there is a Hotel mode (Configuration Nr 80) Your safe service company is able to create additional customized configurations and upload them into the lock for you. www.lock4safe.com...
  • Page 14: L4S User Instructions Pulse Pro En

    1 Override Code, ID 10 1 Manager Code, ID 60 1 Master Code, ID 80 Master can All in dual Dual mode Second Second delete Normal mode for override Manager Master Manager “4-eyes” codes only L4S User Instructions Pulse PRO EN 180105...
  • Page 15 49 User codes , ID 01 to 49 10 Override Codes, ID 50 to 59 1 Manager Code, ID 60 1 Master Code, ID 80 Master can All in dual Dual mode Second Second delete Normal mode for override Manager Master Manager “4-eyes” codes only www.lock4safe.com...
  • Page 16 De Flammert 1002G Boschstr. 16 NL-5854 NA Bergen D - 47533 Kleve T +31 (0)485 551 215 T +49 (0)2821 894 41 90 F +31 (0)485 551 219 F +49 (0)2821 894 41 99 info@lock4safe.com www.lock4safe.com...

Table of Contents