ELECTRICAL WIRING

230V
N
1
2
Valve
Black
D5228
NOTES
– Wires of min. 1 mm
(Unless requested otherwise by local standards
and legislation).
– The electrical wiring carried out by the installer
must be in compliance with the rules in force in
the Country.
– To remove the control-box from the burner,
loosen screw (A) (see figure) and pull
towards the arrow.
– The photoresistance is fitted directly into the
control-box (underneath the ignition-transformer)
on a plug-in support.
TESTING
Check the shut-down of the burner by opening
the thermostats.
2093
~
50Hz
L
Main switch
T6A
N
L
3
4
5
6
Black
Capacitor
2
section.
WARNING
(See page 3). Connect the automatic shut-off
device (230V - 0,5A max.) to the clamps 3 - 6
of control-box.
Remote lock-out lamp
(230V - 0.5A max.), if required
Terminal block of
7
8
9
control-box 530SE
M
~
Motor
A
RUN OF THE ELECTRICAL CABLE
1 - Grommet
2 - Cable-clamp
3 - Terminal block
4
GB
DO NOT EXCHANGE THE
NEUTRAL WITH THE PHASE.
Regulating thermostat
T
Limit thermostat
T
with manual resetting
*
3
2
N - Neutral
L - Phase
- Burner-earth
S7026