What you'll need
• A replacement power supply that is supported for your controller shelf or drive shelf model.
• An ESD wristband, or you have taken other antistatic precautions.

4.2.3. Step 1: Prepare to replace power supply

Prepare to replace a power supply in a 12-drive or 24-drive controller shelf or drive shelf.
Steps
1. Collect support data for your storage array using ThinkSystem System Manager.
a. Select Support › Support Center › Diagnostics.
b. Select Collect Support Data.
c. Click Collect.
The file is saved in the Downloads folder for your browser with the name, support-data.7z.
2. From ThinkSystem System Manager, determine which power supply has failed.
You can find this information in the Details area of the Recovery Guru, or you can review the
information displayed for the shelf.
a. Select Hardware.
b. Look at the power
determine which shelf has the failed power supply.
If a component has failed, either or both of these icons are red.
c. When you find the shelf with a red icon, select Show back of shelf.
d. Select either power supply.
e. On the Power Supplies and Fans tabs, look at the statuses of the power-fan canisters, the
power supplies, and the fans to determine which power supply must be replaced.
A component with a Failed status must be replaced.
If the second power supply canister in the shelf does not have Optimal
status, do not attempt to hot-swap the failed power supply. Instead,
contact technical support for assistance.
3. From the back of the storage array, look at the Attention LEDs to locate the power supply you
need to remove.
You must replace the power supply that has its Attention LED on.
and fan
icons to the right of the Shelf drop-down lists to
39