Electrical Specification; Indicator & Connector - Delta HEH080BB Specification And Manual

Table of Contents

Advertisement

Part no.:
Delta model no.: HEH080BB

2 Electrical Specification

2-1. Indicator & Connector
Power Supply Connector
Power input: AC power input with blade terminal.
(1) AC Power Connect
(2) Electrical connection
Power input: Terminal block 2P with AC L & N input.
(Mate with AWG 12~28 300V 20A)
*Thermostat 1: Off temperature operation range: -20~40°C
Fuse: Cut-out temperature: 167°C
Note: DC Fan is powered by adapter (AC/DC convert.)
The on/off temperature by user to setup
*
Startup average current and inrush current:
The startup average and inrush current waveform are defined as bellow table.
These test are all finished at ambient 25˚C at 230Vac.
Tested waveform to startup average current and inrush current.
Item
Current and time
Typical current: 41.6A
Duration Time: 280usec
Measuring methods:
Inrush
Power on AC input then
current
measure the peak current
value.